局部注射相变声学液滴联合聚桂醇诱导兔肝超声侵蚀

Ultrasound Erosion of Rabbit Liver Induced by Locally Injected Phase-Shift Acoustic Droplets and With Lauromacrogol.
PubMed 文献 · J Ultrasound Med · 2025-01-21

研究在兔肝局部注射全氟甲基环戊烷(PFMCP)或全氟戊烷(PFP)液滴,并联合弱聚焦超声(FUS)处理,观察机械侵蚀效应。结果显示仅FUS联合PFP组出现高回声气泡云及明显肝坏死,坏死面积为FUS+PFMCP组的6.2倍(P<.05),空泡数约为其70倍(P<.001),而单用PFMCP组无坏死和空泡。结论认为仅PFP联合FUS能造成显著机械破坏。

要点

  • 二维超声上FUS+PFP组治疗结束即刻可见高回声气泡云,PFMCP组和FUS+PFMCP组治疗前后无显著差异。
  • FUS+PFP组肝坏死面积为FUS+PFMCP组的6.2倍(P<.05),PFMCP组未见肝坏死。
  • FUS+PFP组肝内空泡数约为FUS+PFMCP组的70倍(P<.001),PFMCP组未见空泡。

核心结论

  • 仅PFP液滴联合FUS能对肝组织造成显著机械破坏,导致液滴注射区域组织坏死;FUS+PFMCP和单用PFMCP的机械侵蚀作用均较差,甚至可能不造成损伤。

研究设计与样本

  • 兔肝实验研究,每只兔肝分别接受单用PFMCP、FUS联合PFMCP(FUS+PFMCP)和FUS联合PFP(FUS+PFP)处理,以二维超声和肝坏死面积、空泡数为观察指标。

关键影像表现/征象

  • FUS+PFP组治疗结束即刻二维超声可见高回声气泡云,PFMCP组和FUS+PFMCP组治疗前后无显著差异。
  • FUS+PFP组肝坏死面积为FUS+PFMCP组的6.2倍(P<.05),PFMCP组未见肝坏死。
  • FUS+PFP组肝内空泡数约为FUS+PFMCP组的70倍(P<.001),PFMCP组未见空泡(P<.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Our previous studies have found that low-frequency, low-pressure, weakly focused ultrasound (FUS) can induce acoustic droplet vaporization (ADV) of perfluoropentane (PFP) droplets and result in localized liver and prostate tissue controllable cavitation resonance and mechanical damage. To further investigate the mechanical erosion induced by ultrasound and locally injected phase-shift acoustic droplets in rabbit liver.

METHODS: The liver of each rabbit was treated with perfluoromethylcyclopentane (PFMCP) alone, FUS combined with PFMCP (FUS + PFMCP), and FUS combined with PFP (FUS + PFP).

RESULTS: Two-dimensional ultrasound images showed that immediately after the completion of FUS + PFP group treatments, a high echogenicity bubble cloud could be observed, while there were no significant differences in the PFMCP and FUS + PFMCP group before and after treatment. The liver necrotic area in the FUS + PFP group was 6.2 times that of the FUS + PFMCP group (P < .05), whereas no liver necrosis was observed in the PFMCP group. At the same time, the number of vacuoles in the liver in the FUS + PFP group was approximately 70 times that of the FUS + PFMCP group (P < .001), whereas no vacuoles were observed in the PFMCP group (P < .001).

CONCLUSIONS: Both FUS + PFMCP and PFMCP alone have poor mechanical erosion in liver tissue, and may even cause no damage. Only PFP droplets combined with FUS can cause significant mechanical destruction of liver tissue, leading to tissue necrosis in the droplet injection area.

来源:J Ultrasound Med,查看原文。版权归原作者所有。