文献速递腹部技术与安全PETCT

68Ga-DOTA-FAPI-04与18F-FDG PET/CT对腹膜癌病诊断准确性的头对头比较

68Ga-DOTA-FAPI-04 and 18F-FDG PET/CT: a head-to-head comparison for peritoneal carcinomatosis diagnostic accuracy.
PubMed 文献 · Abdom Radiol (NY) · 2025-01-03

研究纳入113例疑似腹膜恶性肿瘤患者,每例均行68Ga-FAPI与18F-FDG PET/CT扫描,病灶经病理或影像随访确认。68Ga-FAPI在患者层面的灵敏度、阴性预测值和准确率均高于18F-FDG,且SUVmax、TBR及PCI评分显著更高,尤其在胃癌中表现更优。

要点

  • 68Ga-FAPI PET/CT在患者层面检出腹膜癌病的灵敏度为100%,高于18F-FDG的93.2%。
  • 68Ga-FAPI的SUVmax为6.06±3.04,显著高于18F-FDG的4.82±2.75(P=0.001)。
  • 68Ga-FAPI的PCI评分为11.28±7.10,显著高于18F-FDG的5.69±5.15(P<0.001)。

核心结论

  • 68Ga-FAPI在检测多种类型癌症的腹膜癌病方面诊断准确性优于18F-FDG PET/CT,尤其在胃癌中;且68Ga-FAPI在腹膜癌病中显示出显著更高的摄取和PCI评分,提示其潜在的临床重要性。

研究设计与样本

  • 研究纳入113例疑似腹膜恶性肿瘤患者,每例均行68Ga-FAPI和18F-FDG PET/CT扫描,病灶经病理或影像随访确认。

关键影像表现/征象

  • 68Ga-FAPI PET/CT在患者层面的灵敏度为100%,18F-FDG为93.2%。
  • 68Ga-FAPI PET/CT的阴性预测值为100%,18F-FDG为22.22%。
  • 68Ga-FAPI PET/CT的准确率为93.81%,18F-FDG为86.73%。
  • 68Ga-FAPI的SUVmax为6.06±3.04,18F-FDG为4.82±2.75(P=0.001)。
  • 68Ga-FAPI的TBR为8.50±5.01,18F-FDG为2.92±1.67(P<0.001)。

诊断标准与关键数值

  • 患者层面灵敏度:68Ga-FAPI 100% vs 18F-FDG 93.2%。
  • 患者层面阴性预测值:68Ga-FAPI 100% vs 18F-FDG 22.22%。
  • 患者层面准确率:68Ga-FAPI 93.81% vs 18F-FDG 86.73%。
  • SUVmax:68Ga-FAPI 6.06±3.04 vs 18F-FDG 4.82±2.75(P=0.001)。
  • TBR:68Ga-FAPI 8.50±5.01 vs 18F-FDG 2.92±1.67(P<0.001)。

临床应用与阅片要点

  • 原文结论指出68Ga-FAPI在检测多种类型癌症的腹膜癌病方面诊断准确性优于18F-FDG PET/CT,尤其在胃癌中。
  • 原文结论指出68Ga-FAPI在腹膜癌病中显示出显著更高的摄取和PCI评分,提示其潜在的临床重要性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The study aimed to compare the diagnostic accuracy of 68Ga-DOTA-FAPI-04 (68Ga-FAPI) and 18F-FDG PET/CT for peritoneal carcinomatosis (PC) in patients with various types of cancer.

METHODS: The study enrolled 113 patients with suspected peritoneal malignancy, each of whom underwent 68Ga-FAPI and 18F-FDG PET/CT scans. Lesions in all patients were confirmed through pathology or radiological follow-up. The evaluation and comparison of diagnostic performance, visual scores, maximum standardized uptake value (SUVmax), mean tumor-to-background ratio (TBR), and the peritoneal cancer index (PCI) score were conducted.

RESULTS: Compared to 18F-FDG, 68Ga-FAPI PET/CT presented higher sensitivity, negative predictive value, and accuracy for detecting PC on a patient-level (100% vs. 93.2%, 100% vs. 22.22% and 93.81% vs. 86.73%, respectively). Semi-quantitative evaluation revealed that 68Ga-FAPI PET/CT had significantly higher SUVmax and TBR for PC [(6.06 ± 3.04 vs. 4.82 ± 2.75, P = 0.001) and (8.50 ± 5.01 vs. 2.92 ± 1.67, P < 0.001)]. The PCI-FAPI score for PC was higher than the PCI-FDG score (11.28 ± 7.10 vs. 5.69 ± 5.15, P < 0.001).

CONCLUSIONS: 68Ga-FAPI has demonstrated superior diagnostic accuracy compared to 18F-FDG PET/CT in detecting PC with various types of cancer, particularly gastric cancer. Additionally, 68Ga-FAPI has shown significantly higher uptake and PCI score in PC compared to 18F-FDG, indicating its potential importance in clinical.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Chen X, Pang X, Zhao Y, et al. 68Ga-DOTA-FAPI-04 and 18F-FDG PET/CT: a head-to-head comparison for peritoneal carcinomatosis diagnostic accuracy. Abdom Radiol (NY). 2025. PMID: 39751881. doi:10.1007/s00261-024-04653-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。