光子计数CT对肝脏病灶检出敏感度的影响:一项使用虚拟成像的阅片者研究

Photon-Counting CT Effects on Sensitivity for Liver Lesion Detection: A Reader Study Using Virtual Imaging.
PubMed 文献 · Radiology · 2025-01-01

该阅片者研究使用虚拟成像框架,以50个模体和183个生成肝脏病灶比较模拟光子计数CT与能量积分探测器CT对肝小病灶的检出敏感度。四名放射科医师独立阅片,PCCT共识敏感度为82.1%(451/549),EID CT为77.6%(426/549),差异有统计学意义(P < .001)。

要点

  • PCCT检出肝病灶的共识敏感度为82.1%(451/549),高于EID CT的77.6%(426/549),P < .001。
  • 小于1 cm病灶的敏感度PCCT为74.0%(271/366),EID CT为67.2%(246/366),差异更明显。
  • 低剂量条件下,亚厘米病灶PCCT敏感度为68.9%(168/244),EID CT为61.1%(149/244)。

核心结论

  • 与EID CT相比,PCCT在检出肝脏小病灶方面显示出更好的敏感度。

研究设计与样本

  • 该研究为阅片者研究,使用虚拟成像框架,纳入50个模体和183个生成的肝脏病灶(每个模体1至6个病灶,直径0.4至1.5 cm)。
  • 虚拟CT平台模拟PCCT和EID CT扫描仪,模体在常规剂量(6 mGy)和低剂量(1.5 mGy)条件下虚拟扫描,并使用三种重建核重建。
  • 共选取300次扫描(150对PCCT与EID CT),由四名放射科医师独立阅片标记肝脏病灶、赋予检出置信度评分并评估扫描质量。

关键影像表现/征象

  • PCCT检出病灶的阅片者共识敏感度为82.1%(451/549),EID CT为77.6%(426/549),P < .001。
  • 每名阅片者的平均敏感度增益为4.3个百分点±1.3(每名阅片者P < .001至P = .02)。
  • 小于1 cm病灶的敏感度PCCT为74.0%(271/366),EID CT为67.2%(246/366),P < .001。
  • 低剂量条件下亚厘米病灶的敏感度PCCT为68.9%(168/244),EID CT为61.1%(149/244),P < .001。
  • PCCT的病灶主观置信度评分均值为61.5±22,EID CT为56.1±24(101分制),P < .001;图像质量评分PCCT均值为55.3,EID CT为50.6(101分制),P < .001。

诊断标准与关键数值

  • 以病灶为单位分析敏感度:PCCT共识敏感度82.1%(451/549) vs EID CT 77.6%(426/549),P < .001。
  • 亚组阈值小于1 cm:PCCT敏感度74.0%(271/366) vs EID CT 67.2%(246/366),P < .001。
  • 低剂量(1.5 mGy)条件下亚厘米病灶:PCCT敏感度68.9%(168/244) vs EID CT 61.1%(149/244),P < .001。
  • 多变量模型中PCCT与病灶检出几率增加独立相关(比值比1.55,P < .001)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Detection of hepatic metastases at CT is a daily task in radiology departments that influences medical and surgical treatment strategies for oncology patients. Purpose To compare simulated photon-counting CT (PCCT) with energy-integrating detector (EID) CT for the detection of small liver lesions. Materials and Methods In this reader study (July to December 2023), a virtual imaging framework was used with 50 anthropomorphic phantoms and 183 generated liver lesions (one to six lesions per phantom, 0.4-1.5 cm in diameter). Virtual CT platforms simulated PCCT and EID CT scanners. Phantoms were virtually scanned using routine (6 mGy) and low-dose (1.5 mGy) conditions and reconstructed with three kernels. A subset of 300 scans (150 PCCT vs EID CT pairs) were selected. Four radiologists independently reviewed all scans to mark liver lesions, assigned confidence scores for detection, and rated scan quality. Analysis was performed on a per-lesion basis to determine sensitivity for several variables and on a per-scan basis for scan quality. The McNemar test, two-sided paired t tests, and mixed-effects logistic regression models were fitted; P < .05 was considered indicative of statistically significant difference. Results Consensus reader sensitivity in detecting lesions was 82.1% (451 of 549) for PCCT versus 77.6% (426 of 549) for EID CT (P < .001), with a mean sensitivity gain of 4.3 percentage points ± 1.3 (P < .001 to P = .02 per reader). Readers had better subjective confidence for lesions at PCCT (mean score, 61.5 ± 22 vs 56.1 ± 24 [on a 101-point scale]; P < .001). Sensitivity was lower for lesions smaller than 1 cm, with more pronounced difference between PCCT and EID CT (74.0% [271 of 366] vs 67.2% [246 of 366]; P < .001). At the lower dose level, PCCT showed higher sensitivity than EID CT (68.9% [168 of 244] vs 61.1% [149 of 244]; P < .001) for subcentimeter lesions. In a multivariable model, PCCT was independently associated with increased odds of lesion detection (odds ratio, 1.55; P < .001). Image quality was slightly higher for PCCT (mean score, 55.3 vs 50.6 [on a 101-point scale]; P < .001). Conclusion Compared with EID CT, PCCT showed better sensitivity in the detection of small liver lesions. © RSNA, 2025 Supplemental material is available for this article. See also the editorial by Menu in this issue.