心脏光子计数CT onsite CT-FFR分析评估血流动力学显著狭窄与有创导管血管造影比较的可行性
单中心研究纳入28例梗阻性冠心病患者,均行光子计数探测器CT冠脉成像及后续有创导管造影,以ΔCT-FFR≥0.06为血流动力学显著标准,ΔCT-FFR对有创造影需血运重建的阳性预测值66.7%、阴性预测值100%、诊断准确率74%,39.29%病例可避免不必要的有创造影。
要点
- ΔCT-FFR取狭窄前后1.8 cm处CT-FFR值相减,≥0.06提示血流动力学显著。
- ΔCT-FFR阳性预测值66.7%、阴性预测值100%、诊断准确率74%。
- 39.29%病例通过ΔCT-FFR计算可避免不必要的有创导管造影。
核心结论
- 使用光子计数探测器CT进行ΔCT-FFR分析是识别血流动力学显著冠状动脉狭窄的可行工具,可帮助减少单纯诊断性有创导管造影。
研究设计与样本
- 单中心研究,纳入28例梗阻性冠心病患者(3例女性,中位年龄68岁),均行光子计数探测器CT冠脉成像及后续有创导管造影;以有创造影中行血运重建定义狭窄为血流动力学显著;CT成像后6个月随访评估主要不良心血管事件发生率。
诊断标准与关键数值
- ΔCT-FFR通过狭窄前后1.8 cm处CT-FFR值相减计算,截断值≥0.06提示血流动力学显著;ΔCT-FFR对CAD RADS 4a的阳性预测值66.7%、阴性预测值100%、诊断准确率74%。
临床应用与阅片要点
- ΔCT-FFR计算在39.29%的病例中可避免患者接受不必要的有创导管造影;所有接受血运重建的患者ΔCT-FFR均为病理性,ΔCT-FFR正常者均无需支架置入。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Coronary CT angiography (CCTA) is an excellent tool in ruling out coronary artery disease (CAD) but tends to overestimate especially highly calcified plaques. To reduce diagnostic invasive catheter angiographies (ICA), current guidelines recommend CT-FFR to determine the hemodynamic significance of coronary artery stenosis. Photon-Counting Detector CT (PCCT) revolutionized CCTA and may improve CT-FFR analysis in guiding patients.
METHODS: In this single-center study, patients with obstructive CAD who underwent CCTA using PCCT and subsequent ICA were included. Delta CT-FFR was calculated by subtracting the CT-FFR values 1.8 cm before and after the stenosis, with a cut-off value of ≥0.06 indicating hemodynamic significance. Revascularization during ICA defined a stenosis as hemodynamically significant. Sensitivity, specificity, negative and positive predictive value, and diagnostic accuracy of Delta CT-FFR have been determined. Patients were followed up to evaluate the rate of major adverse cardiovascular events (MACE) 6 months after CCTA.
RESULTS: A total of 28 patients (3 female, median age 68 years) were enrolled in this study. Delta CT-FFR was pathological in all patients who underwent revascularization. No patients with normal Delta CT-FFR required stent placement. In 39.29 % of the cases, calculation of Delta CT-FFR could have prevented patients from undergoing unnecessary ICA. The positive predictive value of Delta CT-FFR for CAD RADS 4a was 66.7 %, negative predictive value 100 %, and diagnostic accuracy 74 %.
CONCLUSION: Delta CT-FFR analysis using PCCT offers a feasible tool in identifying hemodynamically significant coronary artery stenosis and can help to reduce purely diagnostic ICA.
引用
- Ayx I, Lichti L, Buettner S, et al. Feasibility of on-site CT-FFR analysis on cardiac photon-counting CT in evaluation of hemodynamically significant stenosis in comparison to invasive catheter angiography. Eur J Radiol. 2025. PMID: 39823658. doi:10.1016/j.ejrad.2025.111927
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。