文献速递心血管外周血管CTDSA

经导管主动脉瓣置换术患者非冠状动脉专用规划CT血管造影评估旁观者冠状动脉疾病的诊断准确性:一项回顾性真实世界队列研究

Assessment of bystander coronary artery disease in transcatheter aortic valve replacement (TAVR) patients using noncoronary-dedicated planning computed tomography angiography (CTA): diagnostic accuracy in a retrospective real-world cohort.
PubMed 文献 · Clin Radiol · 2024-12-13

回顾性纳入232例同期行非冠状动脉专用预TAVR CTA与有创冠状动脉造影(ICA)的患者,以ICA为金标准评估旁观者冠状动脉疾病。CTA在50%直径狭窄阈值敏感度71%、特异度74%、NPV 92%、PPV 38%;70%阈值敏感度46%、特异度91%、NPV 93%、PPV 41%。作者认为该CTA有助排除显著CAD并可能作为ICA的分流工具。

要点

  • 50%直径狭窄阈值下CTA的NPV为92%,阴性结果对排除显著CAD价值较高。
  • 70%直径狭窄阈值下特异度91%、NPV 93%,但敏感度仅46%。
  • 50%阈值下左主干NPV最高(98%),左前降支为91%。

核心结论

  • 非冠状动脉专用预TAVR CTA在排除显著CAD方面显示潜力,可能作为ICA的分流工具,与典型冠状动脉CT血管造影(CCTA)结果一致。

研究设计与样本

  • 回顾性真实世界队列研究,纳入232例在预TAVR评估中同时接受CTA和ICA的患者。
  • CTA为前瞻性心电门控扫描、无药物预处理、采用标准心脏重建。
  • 排除标准包括既往支架、起搏器、冠状动脉旁路移植或瓣膜手术。
  • 冠状动脉仅通过薄层轴位重建分析,观察者对ICA结果设盲。
  • 以有创冠状动脉造影(ICA)为金标准。

诊断标准与关键数值

  • 狭窄分级:轻度<50%,中度50%-69%,重度≥70%。
  • 50%直径狭窄阈值:敏感度71%、特异度74%、NPV 92%、PPV 38%。
  • 70%直径狭窄阈值:敏感度46%、特异度91%、NPV 93%、PPV 41%。
  • 50%直径狭窄阈值下血管特异性NPV最高为左主干98%、左前降支91%。
  • 70%直径狭窄阈值下血管特异性NPV最高为左主干98%、左回旋支94%。

临床应用与阅片要点

  • 非冠状动脉专用预TAVR CTA可依据50%直径狭窄阈值的NPV(92%)用于排除显著CAD。
  • 70%直径狭窄阈值下特异度91%、NPV 93%,但敏感度仅46%。
  • 图像质量优良(excellent或very good)时诊断效能更高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To assess the diagnostic potential of a noncoronary-dedicated pre-TAVR CT angiography (CTA) conducted as a prospective ECG-gated scan without premedication and standard cardiac reconstructions in evaluating bystander coronary artery disease (CAD) against invasive coronary angiography (ICA) as the gold standard.

MATERIALS AND METHODS: This retrospective study included 232 patients who underwent both CTA and ICA as part of their pre-TAVR evaluation. Exclusion criteria included prior stent, pacemaker, coronary artery bypass, or valve surgery. Coronary arteries were analysed solely through thin-slice axial reconstructions, with observers blinded to ICA results. Stenosis was categorised as mild (< 50%), moderate (50%-69%), or severe (≥70%). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated for 50% and 70% diameter stenosis (DS) thresholds.

RESULTS: At the 50% DS threshold, CTA demonstrated 71% sensitivity, 74% specificity, 92% NPV, and 38% PPV. At the 70% DS threshold, results included 46% sensitivity, 91% specificity, 93% NPV, and 41% PPV. The highest vessel-specific NPV at 50% DS was for the left main (98%) and left anterior descending (LAD) (91%); at 70% DS, left main (LM) (98%) and left circumflex (LCX) (94%) showed the highest NPV. Image quality impacted NPV, with excellent or very good image quality linked to higher diagnostic performance.

CONCLUSION: Noncoronary-dedicated pre-TAVR CTA shows promise for ruling out significant CAD effectively and may act as a gatekeeper for ICA, aligning with typical coronary CT angiography (CCTA) outcomes.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Puseljic M, Prunea D, Toth-Gayor G, et al. Assessment of bystander coronary artery disease in transcatheter aortic valve replacement (TAVR) patients using noncoronary-dedicated planning computed tomography angiography (CTA): diagnostic accuracy in a retrospective real-world cohort. Clin Radiol. 2024. PMID: 39793301. doi:10.1016/j.crad.2024.106776

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。