文献速递心血管US

高帧率对比增强超声心动图评估冠状动脉微循环

Assessment of Coronary Microcirculation with High Frame-Rate Contrast-Enhanced Echocardiography.
PubMed 文献 · Ultrasound Med Biol · 2025-01-04

本研究在猪模型中通过左前降支冠状动脉结扎与释放,采用高帧率对比增强超声(HFR CEUS)结合高阶奇异值分解(HOSVD)离线处理数据,成功区分快慢冠状动脉血流并显示低灌注区和释放后充血,对比剂破坏试验显示在心脏运动最小时处理图像含真实对比信号,但组织运动较大时组织信号渗入对比增强图像。结论提示HFR CEUS联合HOSVD作为评估心肌灌注的可行选项,血流动力学得以解析,可能有助于直接评估冠状动脉血流缺损。

要点

  • HFR CEUS联合HOSVD可区分快慢冠状动脉血流,可能代表微循环不同 compartment。
  • 血管闭塞区域可见低灌注,释放后可见预期充血。
  • 对比剂破坏试验显示心脏运动最小时图像含真实对比信号,组织运动较大时组织信号渗入。

核心结论

  • HFR CEUS联合HOSVD作为评估心肌灌注的可行选项,血流动力学得以解析,可能有助于直接评估冠状动脉血流缺损。

研究设计与样本

  • 猪模型研究,包括左前降支冠状动脉结扎与释放,缓慢输注对比剂,采用HFR CEUS联合HOSVD离线处理数据。

关键影像表现/征象

  • 成功区分快慢冠状动脉血流,可能代表微循环不同 compartment。
  • 血管闭塞影响区域可见低灌注。
  • 释放闭塞后可见预期充血。
  • 对比剂破坏试验显示心脏运动最小时处理图像含真实对比信号。
  • 组织运动较大时组织信号渗入对比增强图像。

局限性

  • 组织运动较大时组织信号渗入对比增强图像。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Assessing myocardial perfusion in acute myocardial infarction is important for guiding clinicians in choosing appropriate treatment strategies. Echocardiography can be used due to its direct feedback and bedside nature, but it currently faces image quality issues and an inability to differentiate coronary macro- from micro-circulation. We previously developed an imaging scheme using high frame-rate contrast-enhanced ultrasound (HFR CEUS) with higher order singular value decomposition (HOSVD) that provides dynamic perfusion and vascular flow visualization. In this study, we aim to show the ability of this technique to image perfusion deficits and investigate the potential occurrence of false-positive contrast detection.

METHODS: We used a porcine model comprising occlusion and release of the left anterior descending coronary artery. During slow contrast agent infusion, the afore-mentioned imaging scheme was used to capture and process the data offline using HOSVD.

RESULTS: Fast and slow coronary flow was successfully differentiated, presumably representing the different compartments of the micro-circulation. Low perfusion was seen in the area that was affected, as expected by vascular occlusion. Furthermore, we also imaged coronary flow dynamics before, during and after release of the occlusion, the latter showing hyperemia as expected. A contrast agent destruction test showed that the processed images contained actual contrast signal in the cardiac phases with minimal motion. With larger tissue motion, tissue signal leaked into the contrast-enhanced images.

CONCLUSION: Our results demonstrate the feasibility of HFR CEUS with HOSVD as a viable option for assessing myocardial perfusion. Flow dynamics were resolved, which potentially helped to directly evaluate coronary flow deficits.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Wahyulaksana G, Wei L, Voorneveld J, et al. Assessment of Coronary Microcirculation with High Frame-Rate Contrast-Enhanced Echocardiography. Ultrasound Med Biol. 2025. PMID: 39757049. doi:10.1016/j.ultrasmedbio.2024.12.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。