心脏血栓:T1与T2定量成像能否替代对比增强图像?
该回顾性研究对22例心脏血栓患者的T1、T2定量图像及对比增强图像进行信噪比和对比噪声比评估,发现早期钆增强和晚期钆增强图像对血栓与血池、心肌的区分能力优于T1、T2定量图像;作者认为平扫定量序列在检测心脏血栓方面可能有潜力,但对比增强图像更优。
要点
- 评估心脏血栓时,早期钆增强和晚期钆增强图像对血栓与血池、心肌的区分能力优于T1、T2定量图像。
- 平均对比噪声比在早期钆增强最高,其次为晚期钆增强,再次为定量图像。
- 作者认为平扫定量序列在检测心脏血栓方面可能有潜力,但对比增强图像更优。
核心结论
- 作者认为平扫定量序列在检测心脏血栓方面可能有潜力,但对比增强图像更优。
研究设计与样本
- 回顾性研究,纳入22例心脏血栓患者,评估T1定量、T2定量及对比增强图像的SNR和CNR,比较血栓、血池和心肌的测量值。
关键影像表现/征象
- 在早期钆增强和晚期钆增强图像上,血栓与血池及心肌的区分能力优于T1和T2定量图像。
诊断标准与关键数值
- 平均CNR在早期钆增强最高,其次为晚期钆增强,再次为T1和T2定量图像。
临床应用与阅片要点
- 作者认为平扫定量序列在检测心脏血栓方面可能有潜力,但对比增强图像更优。
- 未来研究可通过不同改良Look-Locker反转恢复方案或其他T1、T2定量方法确定平扫评估血栓的最佳定量序列。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: The aim of the study was to evaluate and compare contrast-to-noise ratios (CNRs) and signal-to-noise ratios (SNRs) of pre- and postcontrast T1 maps, T2 maps, early and late gadolinium images in terms of visual assessment of cardiac thrombus, to see if maps can replace contrast-enhanced images for detection of cardiac thrombus.
MATERIALS AND METHODS: T1, T2 maps, and postcontrast images of 22 patients with cardiac thrombus were retrospectively evaluated for SNR and CNR. SNR and CNR values of thrombus, blood pool, and myocardium measured at maps and contrast-enhanced images were compared with each other.
RESULTS: The distinguishability of thrombus from blood pool and myocardium was better on early gadolinium images (EGE) and late gadolinium enhanced (LGE) images than T1 and T2 mapping. The mean CNRs calculated to be the highest on EGE, followed by LGE and then maps.
CONCLUSION: Native mapping sequences may have a potential in detecting cardiac thrombus, but contrast-enhanced images are superior. In future studies, the optimal mapping sequence for evaluation of thrombus in noncontrast images can be determined by using different modified Look-Locker inversion recovery schemes or other T1 and T2 mapping methods.
PRECIS: CNR values of EGE and LGE remained higher than mapping sequences.