心脏MRI伪影:影像表现与解决方案

Artifacts at Cardiac MRI: Imaging Appearances and Solutions.
PubMed 文献 · Radiographics · 2025-01-01

心脏MRI是评估心血管疾病的重要影像方法,但采集技术复杂,常出现通用及序列特异性伪影。本文阐述bSSFP、LGE、相位对比、首过灌注等序列伪影的成因与识别,并给出针对性抑制方案,包括3T适应、非门控实时序列、宽频序列等。

要点

  • bSSFP序列易出现条带与血流伪影,3T时放大,可通过靶向匀场、短TR或频率预扫描序列减轻。
  • 心律失常或屏气不佳者,可用非心电门控自由呼吸实时序列改善电影成像质量。
  • LGE伪影可用单次激发结合运动补偿与信号平均减轻;植入设备所致模拟瘢痕高信号可用宽频序列减轻。

核心结论

  • 识别心脏MRI伪影、理解其成因并采取有效抑制方法,是成功完成心脏MRI的关键。

研究设计与样本

  • 综述类文章,总结心脏MRI各序列伪影的影像表现与解决方案,原文未报告检索范围与纳入文献。

关键影像表现/征象

  • bSSFP序列可见条带伪影与血流伪影,3T成像时放大。
  • LGE图像上植入心脏设备可产生模拟瘢痕的高信号伪影。
  • 相位对比成像中,血流速度高于编码速度时出现混叠伪影。
  • 首过灌注成像中,Gibbs振铃所致暗边环伪影出现较早,数个心动周期后消退。

诊断标准与关键数值

  • 暗边环伪影与真性灌注缺损的鉴别依据为出现更早、数个心动周期后消退。
  • 相位对比混叠伪影见于血流速度高于编码速度时。

临床应用与阅片要点

  • bSSFP条带与血流伪影可通过靶向匀场、短重复时间或频率预扫描序列减轻。
  • 心律失常或屏气不佳患者,可用非心电门控自由呼吸实时序列改善电影成像质量。
  • LGE运动伪影可用单次激发技术结合运动补偿与信号平均减轻。
  • 设备伪影可用宽频序列减轻;有设备与金属伪影时,传统梯度回波序列伪影少于bSSFP。
  • 3T心脏MRI需调整序列以尽量减少伪影。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Cardiac MRI (CMR) is an important imaging modality in the evaluation of cardiovascular diseases. CMR image acquisition is technically challenging, which in some circumstances is associated with artifacts, both general as well as sequence specific. Recognizing imaging artifacts, understanding their causes, and applying effective approaches for artifact mitigation are critical for successful CMR. Balanced steady-state free precession (bSSFP), the most common CMR sequence, is associated with band and flow artifacts, which are amplified at 3-T imaging. This can be mitigated by targeted shimming, by short repetition time, or by using a frequency-scout sequence. In patients with cardiac arrhythmias or poor breath hold, the quality of cine imaging can be improved with a non-electrocardiographically gated free-breathing real-time sequence. Motion artifacts on late gadolinium enhancement (LGE) images can be mitigated by using single-shot technique with motion compensation and signal averaging. LGE images are also prone to partial-volume averaging and incomplete myocardial nulling. In phase-contrast imaging, aliasing artifact is seen when the velocity of blood is higher than the encoded velocity. Aliasing can be mitigated by increasing the encoded velocity or using postprocessing software. In first-pass perfusion imaging, a dark rim artifact due to Gibbs ringing can be distinguished from a true perfusion defect based on earlier appearance and fading after a few cardiac cycles. With implanted cardiac devices, artifactual high signal intensity mimicking scar is seen on LGE images, which can be mitigated using a wide-band sequence. With devices and metallic artifacts, traditional gradient-recalled echo sequence has fewer artifacts than bSSFP. CMR at 3 T requires adaptation of sequences to minimize artifacts. ©RSNA, 2025 Supplemental material is available for this article.