文献速递胸部CT

基于能谱CT衍生参数与肿瘤异常蛋白水平预测混合磨玻璃结节侵袭性:模型开发与验证

Predicting the Invasiveness of Mixed Ground-Glass Nodules Based on Spectral Computed Tomography-Derived Parameters and Tumor Abnormal Protein Levels: Development and Validation of a Model.
PubMed 文献 · Acad Radiol · 2025-01-02

前瞻性研究纳入混合磨玻璃结节患者行术前三相增强能谱双层探测器CT及TAP、TK1检测,以病理侵袭性分组,用397例训练与内部验证、144例外部队列构建含CT100keV_a、Zeff_a、ED_a、TAP、Dsolid及支气管内形态的列线图,三队列AUC 0.840-0.911,训练集最佳截断值0.566时敏感度88.2%、特异度80.4%。

要点

  • 能谱CT参数Zeff_a在预测混合磨玻璃结节侵袭性中作用突出。
  • 联合CT100keV_a、Zeff_a、ED_a、TAP、Dsolid及支气管内形态的列线图三队列AUC 0.840-0.911。
  • 训练集最佳截断值0.566,敏感度88.2%、特异度80.4%。

核心结论

  • 多个能谱双层探测器CT衍生参数可预测混合磨玻璃结节侵袭性,其中Zeff_a作用突出;所建能谱CT参数-TAP列线图诊断性能优良且校准准确度高,有助于对恶性混合磨玻璃结节进行个体化无创风险预测。

研究设计与样本

  • 前瞻性研究,纳入术前接受三相增强能谱双层探测器CT并完成TAP与TK1检测的混合磨玻璃结节患者,按病理侵袭性分为非侵袭性与侵袭性腺癌;397例分为训练队列与内部验证队列,另144例为外部验证集,构建预测侵袭性混合磨玻璃结节的列线图并以受试者工作特征曲线评估。

诊断标准与关键数值

  • CT100keV_a、Zeff_a、ED_a、TAP、Dsolid及支气管内形态被确定为混合磨玻璃结节侵袭性的独立危险因素。

临床应用与阅片要点

  • 所建能谱CT参数-TAP列线图在三个数据集中曲线下面积为0.840-0.911,训练集最佳截断值为0.566,对应敏感度88.2%、特异度80.4%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Mixed ground-glass nodules (mGGNs) are highly malignant and common nonspecific lung imaging findings. This study aimed to explore whether combining quantitative and qualitative spectral dual-layer detector-based computed tomography (SDCT)-derived parameters with serological tumor abnormal proteins (TAPs) and thymidine kinase 1 (TK1) expression enhances invasive mGGN diagnostic efficacy and to develop a joint diagnostic model.

MATERIALS AND METHODS: This prospective study included patients with mGGNs undergoing preoperative triple-phase contrast-enhanced SDCT with TAP and TK1 tests. Based on pathologic invasiveness, mGGNs were classified as noninvasive or invasive adenocarcinomas. To establish the predictive model, 397 patients were divided into training and internal validation cohorts. Another 144 patients comprised the external validation set. A nomogram predicting invasive mGGNs was generated and assessed using receiver operating characteristic curves.

RESULTS: CT100keV_a, Zeff_a, ED_a, TAP, Dsolid, and Internal_bronchial_morphology were identified as independent risk factors for mGGN invasiveness. The SDCT parameter-TAP nomogram combining these six predictors demonstrated satisfactory discrimination capabilities in all three datasets (areas under the curves 0.840-0.911). The optimal training set cutoff was 0.566, yielding an 88.2% sensitivity and 80.4% specificity. Decision curve analysis showed the highest net benefit across a breadth of threshold probabilities, and clinical impact curve analysis confirmed the model's clinical validity. The nomogram had significantly higher discriminative accuracy than any variable alone.

CONCLUSION: Multiple SDCT-derived parameters predict mGGN invasiveness, with Zeff_a playing a prominent role. The developed SDCT parameter-TAP nomogram has excellent diagnostic performance and high calibration accuracy, facilitating individual noninvasive risk prediction of malignant mGGNs.

CRITICAL RELEVANCE STATEMENT: Multiple quantitative and functional parameters derived from SDCT can predict the pathological invasiveness of mGGNs, with Zeff_a playing a prominent role. A SDCT parameters-TAP nomogram has excellent diagnostic performance and high calibration accuracy, facilitating noninvasive prediction of individual risks of malignant mGGNs.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Fan Z, Yue Y, Lu X, et al. Predicting the Invasiveness of Mixed Ground-Glass Nodules Based on Spectral Computed Tomography-Derived Parameters and Tumor Abnormal Protein Levels: Development and Validation of a Model. Acad Radiol. 2025. PMID: 39753480. doi:10.1016/j.acra.2024.12.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。