自适应统计迭代重建-V算法与深度学习图像重建算法对COPD患者超低剂量条件下图像质量和肺气肿定量的影响
前瞻性纳入62例COPD患者,行肺功能检查、标准剂量CT(SDCT,FBP重建)和超低剂量CT(ULDCT,分别用FBP、30%ASIR-V、60%ASIR-V、90%ASIR-V、DLIR-L、DLIR-M、DLIR-H重建)。ULDCT辐射剂量0.46±0.22 mSv,较SDCT降低93.8%(P<.001)。DLIR-M在图像质量和肺气肿定量方面表现最佳。
要点
- ULDCT辐射剂量0.46±0.22 mSv,较SDCT降低93.8%(P<.001)。
- ULDCT-DLIR-M与SDCT-FBP的图像噪声、EI及PD15值相似(均P>.05)。
- ULDCT-DLIR-M的EI与FEV1/FVC、FEV1%相关性最佳,EI和PD15与SDCT-FBP偏差最低。
核心结论
- DLIR-M在ULDCT条件下为COPD患者提供最佳的图像质量和肺气肿定量;超低剂量CT联合DLIR-M重建在肺气肿定量分析和图像质量方面与标准剂量图像相当。
研究设计与样本
- 前瞻性研究,纳入62例COPD患者,行肺功能检查、标准剂量CT和超低剂量CT;SDCT图像用FBP重建,ULDCT图像用FBP、30%ASIR-V、60%ASIR-V、90%ASIR-V、DLIR-L、DLIR-M、DLIR-H重建共8组图像;使用商业计算机辅助诊断软件分析,两名放射科医生用5分法评估气管和肺动脉图像质量。
关键影像表现/征象
- 8组图像的肺体积和平均肺密度无差异(P>.05)。
- ULDCT-ASIR-V90%和ULDCT-DLIR-M的图像噪声、EI和PD15值与SDCT-FBP相似(均P>.05)。
- ULDCT-DLIR-M和ULDCT-DLIR-H的主观评分与SDCT-FBP相似(均P>.05)。
- ULDCT-DLIR-M的EI与肺功能FEV1/FVC和FEV1%指标相关性最佳,EI和PD15与SDCT-FBP偏差最低。
诊断标准与关键数值
- 图像质量主观评估采用5分法,由两名放射科医生对气管和肺动脉进行评分。
- 肺气肿定量参数包括肺体积、肺气肿指数、平均肺密度和第15百分位肺密度,由商业计算机辅助诊断软件测量。
- ULDCT辐射剂量0.46±0.22 mSv,较SDCT降低93.8%(P<.001)。
临床应用与阅片要点
- 在超低剂量CT条件下,DLIR-M重建的图像噪声、肺气肿指数和PD15值与标准剂量FBP图像相似,可用于肺气肿定量分析。
- DLIR-M重建的肺气肿指数与肺功能指标相关性最佳,与标准剂量FBP的偏差最低。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To explore the effect of different reconstruction algorithms (ASIR-V and DLIR) on image quality and emphysema quantification in chronic obstructive pulmonary disease (COPD) patients under ultra-low-dose scanning conditions.
MATERIALS AND METHODS: This prospective study with patient consent included 62 COPD patients. Patients were examined by pulmonary function test (PFT), standard-dose CT (SDCT) and ultra-low-dose CT (ULDCT). SDCT images were reconstructed with filtered-back-projection (FBP), while ULDCT images were reconstructed using FBP, 30%ASIR-V, 60%ASIR-V, 90%ASIR-V, low-strength (DLIR-L), medium-strength (DLIR-M) and high-strength DLIR (DLIR-H) to form 8 image sets. Images were analysed using a commercial computer aided diagnosis (CAD) software. Parameters such as image noise, lung volume (LV), emphysema index (EI), mean lung density (MLD) and 15th percentile of lung density (PD15) were measured. Two radiologists evaluated tracheal and pulmonary artery image quality using a 5-point scale. Measurements were compared and the correlation between EI and PFT indices was analysed.
RESULT: ULDCT used 0.46 ± 0.22 mSv in radiation dose, 93.8% lower than SDCT (P < .001). There was no difference in LV and MLD among image groups (P > .05). ULDCT-ASIR-V90% and ULDCT-DLIR-M had similar image noise and EI and PD15 values to SDCT-FBP, and ULDCT-DLIR-M and ULDCT-DLIR-H had similar subjective scores to SDCT-FBP (all P > .05). ULDCT-DLIR-M provided the best correlation between EI and the FEV1/FVC and FEV1% indices in PFT, and the lowest deviations with SDCT-FBP in both EI and PD15.
CONCLUSION: DLIR-M provides the best image quality and emphysema quantification for COPD patients in ULDCT.
ADVANCES IN KNOWLEDGE: Ultra-low-dose CT scanning combined with DLIR-M reconstruction is comparable to standard dose images for quantitative analysis of emphysema and image quality.
引用
- Ma G, Dou Y, Dang S, et al. Effect of adaptive statistical iterative reconstruction-V algorithm and deep learning image reconstruction algorithm on image quality and emphysema quantification in COPD patients under ultra-low-dose conditions. Br J Radiol. 2025. PMID: 39862404. doi:10.1093/bjr/tqae251