文献速递胸部CT

利用生成对抗网络风格转换减少CT供应商差异以改善间质性肺病定量的功能相关性

Improving functional correlation of quantification of interstitial lung disease by reducing the vendor difference of CT using generative adversarial network (GAN) style conversion.
PubMed 文献 · Eur J Radiol · 2024-12-22

回顾性纳入112例特发性肺纤维化患者,评估使用可路由生成对抗网络(RouteGAN)将A厂商CT转换为B厂商风格后对间质性肺病定量变异及功能相关性的影响。转换后网格影、蜂窝影和磨玻璃影的CCC分别为0.20、0.72和0.59,视觉准确性评分提高(P<0.001),纤维化评分与FVC及DLCO的相关性均显著增强。

要点

  • RouteGAN风格转换可提高深度学习间质性肺病定量的视觉准确性(P<0.001)。
  • 转换后纤维化评分与FVC相关性由-0.35增至-0.50(P=0.005)。
  • 转换后纤维化评分与DLCO相关性由-0.50增至-0.66(P<0.001)。

核心结论

  • 应用基于GAN的CT风格转换后,深度学习间质性肺病定量准确性的提高可改善IPF患者定量CT测量的功能相关性。

研究设计与样本

  • 回顾性研究,纳入112例接受A厂商胸部平扫CT及肺功能检查的IPF患者(平均年龄61岁,82例男性),使用RouteGAN生成A到B风格的转换图像,以B厂商CT开发的深度学习间质性肺病定量软件进行定量。

诊断标准与关键数值

  • 原始与转换CT间测量变异性的一致性相关系数:网格影CCC=0.20,蜂窝影CCC=0.72,磨玻璃影CCC=0.59。
  • 转换图像定量的视觉准确性评分中位数高于原始图像(P<0.001)。
  • 纤维化评分与FVC相关性:原始-0.35 vs 转换-0.50(P=0.005)。
  • 纤维化评分与DLCO相关性:原始-0.50 vs 转换-0.66(P<0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess whether CT style conversion between different CT vendors using a routable generative adversarial network (RouteGAN) could minimize variation in ILD quantification, resulting in improved functional correlation of quantitative CT (QCT) measures.

METHODS: Patients with idiopathic pulmonary fibrosis (IPF) who underwent unenhanced chest CTs with vendor A and a pulmonary function test (PFT) were retrospectively evaluated. As deep-learning based ILD quantification software was mainly developed using vendor B CT, style-converted images from vendor A to B style were generated using RouteGAN. Quantification was performed in both original and converted images. Measurement variability in QCT between original and converted images was evaluated using the concordance correlation coefficient (CCC). Two radiologists visually evaluated quantification accuracy using original and converted images. Correlations between CT parameters and PFT measures were assessed.

RESULTS: Total 112 patients (mean age, 61; 82 men) were studied. Measurement variability between original and converted CT was a CCC of 0.20 for reticulation, 0.72 for honeycombing, and 0.59 for ground-glass opacity. The median visual accuracy scores were higher for the quantification using converted compared with the original images (P < 0.001). Correlation between fibrosis score increased significantly after CT conversion for both forced vital capacity (original vs. converted; -0.35 vs. -0.50; P = 0.005) and diffusing capacity of the lung for carbon monoxide (-0.50 vs. -0.66; P < 0.001).

CONCLUSION: The improved accuracy in deep learning based ILD quantification after applying GAN-based CT style conversion can result in the improved functional correlation of QCT measurements in patients with IPF.

来源:Eur J Radiol,查看原文。版权归原作者所有。