慢性阻塞性肺疾病中节拍器节律快速呼吸诱发的动态肺过度充气的MRI评估:SPIROMICS-HF研究
SPIROMICS-HF横断面研究纳入70例参与者(59%患COPD),采用二维冠状位实时电影肺MRI(3.2帧/秒)在节拍器节律快速呼吸(MPT)期间两次评估动态肺过度充气,迁移学习模型肺分割Dice系数0.94±0.03,EELV和动态肺过度充气的重测组内相关系数分别为0.99和0.87,动态肺过度充气与COPD严重程度相关(P趋势=.01,重度COPD与对照均值差0.24 L)。
要点
- 实时电影肺MRI可在MPT期间量化动态肺过度充气,EELV重测组内相关系数0.99、动态肺过度充气0.87。
- 迁移学习模型肺分割Dice相似系数0.94±0.03,支持可重复的定量分析。
- 动态肺过度充气与COPD严重程度相关(P趋势=.01),重度COPD与对照均值差0.24 L。
核心结论
- 迁移学习模型在实时电影肺MRI上实现了MPT诱发的动态肺过度充气的可重复量化,COPD越严重者动态肺过度充气越大。
研究设计与样本
- SPIROMICS-HF为2019年12月至2024年4月开展的横断面研究,评估COPD心肺相互作用,纳入70例有≥20包年吸烟史的COPD患者及40-80岁对照,采用二维冠状位实时电影肺MRI(3.2帧/秒)在MPT期间行两次扫描,并用独立研究的肺掩膜和MR图像进行迁移学习分割。
诊断标准与关键数值
- 动态肺过度充气定义为MPT结束时潮式呼吸呼气末肺容积(EELV)的增加量;扫描-重扫描EELV的组内相关系数为0.99、动态肺过度充气为0.87;肺分割Dice相似系数为0.94±0.03。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To assess the repeatability of real-time cine pulmonary MRI measures of metronome-paced tachypnea (MPT)-induced dynamic hyperinflation and its relationship with chronic obstructive pulmonary disease (COPD) severity. Materials and Methods SubPopulations and InteRmediate Outcome Measures In COPD Study (SPIROMICS) (ClinicalTrials.gov identifier no. NCT01969344) is a multicenter prospective cohort study that recruited individuals with COPD with 20 or more pack-years smoking history and controls aged 40-80 years. SPIROMICS-HF is a cross-sectional study evaluating cardiopulmonary interactions in COPD from December 2019 to April 2024. Two-dimensional coronal real-time cine pulmonary MRI (3.2 frames/sec) was performed during MPT twice. Lung masks and lung MR images from an independent study were used for transfer learning to segment real-time cine pulmonary MR images. Dynamic hyperinflation was evaluated as the increase in end-expiratory lung volume (EELV) during tidal breathing to the end of MPT. Repeatability was assessed with intraclass correlation coefficients, and multivariable associations with COPD severity were examined. Results Of the 70 participants (mean age, 67 years ± 10 [SD]; 37 male, 33 female) included in the study, 59% had COPD. The transfer learning model achieved high accuracy in lung segmentation (Dice similarity coefficient, 0.94 ± 0.03). There was good scan-rescan agreement for EELV and dynamic hyperinflation (intraclass correlation coefficient, 0.99 and 0.87, respectively). Dynamic hyperinflation was associated with COPD severity (P trend = .01, with a mean difference between severe COPD and controls of 0.24 L). Conclusion A transfer learning model yielded reproducible quantification of MPT-induced dynamic hyperinflation at real-time cine pulmonary MRI, with greater dynamic hyperinflation in participants with more severe COPD. Keywords: Chronic Obstructive Pulmonary Disease, MR Imaging, Pulmonary, Lung, Technology Assessment Supplemental material is available for this article. ClinicalTrials.gov identifier: NCT01969344 © RSNA, 2025.
引用
- Zhang X, Cooper CB, Prince MR, et al. MRI-assessed Dynamic Hyperinflation Induced by Tachypnea in Chronic Obstructive Pulmonary Disease: The SPIROMICS-HF Study. Radiol Cardiothorac Imaging. 2025. PMID: 39836055. doi:10.1148/ryct.240053
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。