文献速递胸部儿科影像技术与安全CT

自由呼吸呼吸触发高螺距肺CT:体模与患者扫描的启示

Free-Breathing Respiratory Triggered High-Pitch Lung CT: Insights From Phantom and Patient Scans.
PubMed 文献 · Invest Radiol · 2025-01-24

研究在动态胸部体模中验证呼吸触发高螺距CT(RT-HPCT)算法,并在18例自由呼吸患者中前瞻性行RT-HPCT、与20例常规自由呼吸HPCT对照,结果显示RT-HPCT整体图像质量显著优于常规HPCT(P<0.001),平均肺容积RT组4.0 L±1.1 L、对照组3.6 L±1.0 L。

要点

  • 呼吸触发高螺距CT可在自由呼吸下于吸气末和呼气末启动扫描,减少呼吸运动伪影。
  • 患者研究中RT-HPCT整体图像质量较常规HPCT显著改善(P<0.001)。
  • 体模中实际触发相位与目标相位平均偏差1.6 mm±4.7 mm,相当于运动范围的15%±24%。

核心结论

  • 研究证实患者自适应呼吸触发算法用于高螺距肺CT在体模和患者中均可行,呼吸触发高螺距CT较常规非触发自由呼吸扫描显著减少呼吸伪影。

研究设计与样本

  • 体模验证加前瞻性患者研究:算法在动态组织等效胸部运动体模上以28种源自不规则呼吸患者的呼吸运动模式测试,患者组18例行前瞻性RT-HPCT,对照组20例行无呼吸触发的自由呼吸非增强HPCT。

关键影像表现/征象

  • 体模扫描中实际触发相位与目标相位的平均偏差为1.6 mm±4.7 mm,相当于体模运动范围的15%±24%。
  • 患者扫描中RT-HPCT整体图像质量较常规HPCT显著改善(P<0.001)。
  • 定量平均肺容积RT组为4.0 L±1.1 L,对照组为3.6 L±1.0 L。

诊断标准与关键数值

  • 体模图像质量通过比较静止与运动采集来近似评估,患者扫描的呼吸运动伪影与吸气深度由肺解剖专家知识及自动肺容积估算分析。
  • 平均CTDI:HPCT为1.73 mGy±0.1 mGy,RT-HPCT为1.68 mGy±0.1 mGy。

临床应用与阅片要点

  • 对儿童、老年人或镇静等无法配合深吸气屏气的患者,可采用自由呼吸下呼吸触发高螺距CT于吸气末或呼气末启动扫描。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Respiratory motion can affect image quality and thus affect the diagnostic accuracy of CT images by masking or mimicking relevant lung pathologies. CT examinations are often performed during deep inspiration and breath-hold to achieve optimal image quality. However, this can be challenging for certain patient groups, such as children, the elderly, or sedated patients. The study aimed to validate a dedicated triggering algorithm for initiating respiratory-triggered high-pitch computed tomography (RT-HPCT) scans in end inspiration and end expiration in complex and irregular respiratory patterns using an anthropomorphic dynamic chest phantom. Additionally, a patient study was conducted to compare the image quality and lung expansion between RT-HPCT and standard HPCT.

MATERIALS AND METHODS: The study utilized an algorithm that processes the patient's breathing motion in real-time to determine the appropriate time to initiate a scan. This algorithm was tested on a dynamic, tissue-equivalent chest motion phantom to replicate and simulate 3-dimensional target motion using 28 breathing motion patterns taken from patient with irregular breathing. To evaluate the performance on human patients, prospective RT-HPCT was performed in 18 free-breathing patients. As a reference, unenhanced HPCT of the chest was performed in 20 patients without respiratory triggering during free-breathing. The mean CTDI was 1.73 mGy ± 0.1 mGy for HPCT and 1.68 mGy ± 0.1 mGy for RT-HPCT. For phantom tests, the deviation from the target position of the phantom inlay is known. Image quality is approximated by evaluating stationary versus moving acquisitions. For patient scans, respiratory motion artifacts and inspiration depth were analyzed using expert knowledge of lung anatomy and automated lung volume estimation. Statistical analysis was performed to compare image quality and lung volumes between conventional HPCT and RT-HPCT.

RESULTS: In phantom scans, the average deviation from the desired excursion phase was 1.6 mm ± 4.7 mm or 15% ± 24% of the phantom movement range. In patients, the overall image quality significantly improved with respiratory triggering compared with conventional HPCT ( P < 0.001). Quantitative average lung volume was 4.0 L ± 1.1 L in the RT group and 3.6 L ± 1.0 L in the control group.

CONCLUSIONS: This study demonstrated the feasibility of using a patient-adaptive respiratory triggering algorithm for high-pitch lung CT in both phantom and patients. Respiratory-triggered high-pitch CT scanning significantly reduces breathing artifacts compared with conventional nontriggered free-breathing scans.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Schwarz A, Hofmann C, Dickmann J, et al. Free-Breathing Respiratory Triggered High-Pitch Lung CT: Insights From Phantom and Patient Scans. Invest Radiol. 2025. PMID: 39847727. doi:10.1097/RLI.0000000000001157

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。