「轮廓征」:薄层高强化边缘作为脑膜瘤的MR影像特征——在颞骨区域鉴别脑膜瘤与神经鞘瘤及副神经节瘤的有用工具
本研究回顾性分析39例经组织病理学证实的脑膜瘤、神经鞘瘤及副神经节瘤的临床MRI,评估自旋回波增强T1加权图像上脑膜瘤边缘薄层曲线样高强化线(轮廓征)的实用性。轮廓征在14例脑膜瘤中12例(86%)出现,显著高于神经鞘瘤(22例中3例,14%)和副神经节瘤(3例中1例,33%),鉴别脑膜瘤的敏感度86%、特异度84%、准确率85%。结论认为轮廓征可作为诊断脑膜瘤的有用工具,可能有助于在颞骨区域区分脑膜瘤与其他强化肿瘤。
要点
- 轮廓征指自旋回波增强T1加权图像上脑膜瘤边缘的薄层曲线样高强化线。
- 轮廓征在脑膜瘤出现频率(86%)显著高于神经鞘瘤(14%)和副神经节瘤(33%)。
- 轮廓征鉴别脑膜瘤的敏感度86%、特异度84%、准确率85%,读者间一致性Cohen κ为0.74。
核心结论
- 轮廓征可作为诊断脑膜瘤的有用工具,可能有助于在颞骨区域将脑膜瘤与其他强化肿瘤(如神经鞘瘤和副神经节瘤)区分开来。
研究设计与样本
- 回顾性研究,共纳入39例经组织病理学证实的脑膜瘤、神经鞘瘤和副神经节瘤的临床MRI;由两名经验丰富的头颈放射科医生独立评估轮廓征的有无,并在不知晓患者信息和组织病理学数据的情况下形成共识意见;读者间信度采用Cohen κ统计评估。
关键影像表现/征象
- 轮廓征表现为自旋回波增强T1加权图像上沿脑膜瘤边缘的薄层曲线样高强化线。
诊断标准与关键数值
- 轮廓征在14例脑膜瘤中12例(86%)出现,显著高于神经鞘瘤(22例中3例,14%)和副神经节瘤(3例中1例,33%);轮廓征识别潜在脑膜瘤的敏感度86%、特异度84%、准确率85%;两名读者在39例中34例(87%)对轮廓征评估意见一致,包括14例脑膜瘤中13例(93%),一致性为中等(Cohen κ为0.74)。
临床应用与阅片要点
- 在颞骨区域(如小脑脑桥角或颈静脉孔)的鉴别诊断中,观察自旋回波增强T1加权图像上是否存在轮廓征,可能有助于提高脑膜瘤的诊断信心。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: This study investigates the practicality and utility of the "outline sign," which refers to the thin curvilinear hyperenhancing line that may be seen along the margin of a meningioma on a spin-echo postcontrast T1-weighted image. For cases in which the differential diagnosis may include other tumors, visualization of the outline sign may help to increase the diagnostic confidence for a meningioma. Therefore, in the temporal bone region such as the cerebellopontine angle or jugular foramen, where differential considerations may include a schwannoma or paraganglioma, we additionally investigated whether the outline sign may be observed in these nonmeningioma lesions.
MATERIALS AND METHODS: A total of 39 clinical MRIs of meningiomas, schwannomas, and paragangliomas with confirmed histopathologic data were studied retrospectively. Two experienced head and neck radiologists independently assessed for the presence or absence of an outline sign and subsequently formed a consensus opinion while blinded to patient information and histopathologic data. Interreader reliability was assessed by Cohen κ statistics. Simple bivariate comparisons were performed on the consensus opinions to assess for statistical differences in presence of the sign in meningiomas versus schwannomas and paragangliomas. Sensitivity, specificity, and accuracy of the sign with respect to identifying an underlying meningioma were calculated.
RESULTS: Both readers displayed identical opinions in assessment of the outline sign in 34 of the 39 cases (87%), including 13 of the 14 meningiomas (93%), with substantial agreement (Cohen κ of 0.74). The outline sign was present in 12 of 14 meningiomas (86%), which was significantly greater in frequency compared with schwannomas (3 of 22, 14%) and paragangliomas (1 of 3, 33%). The outline sign demonstrated high sensitivity (86%), specificity (84%), and accuracy (85%) in identifying an underlying meningioma.
CONCLUSIONS: The outline sign can serve as a useful tool for diagnosing meningiomas. It may help distinguish meningiomas from other enhancing tumors, for example schwannomas and paragangliomas in the temporal bone region.
引用
- Vasireddi AK, Reinshagen KL, Shin D, et al. The "Outline Sign": Thin Hyperenhancing Perimeter as an MR Imaging Feature of Meningioma. A Useful Tool in the Temporal Bone Region for Differentiating Meningiomas from Schwannomas and Paragangliomas. AJNR Am J Neuroradiol. 2025. PMID: 39788629. doi:10.3174/ajnr.A8452
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。