基于深度学习重建的加速脑MRI前瞻性评估:同步应用于二维自旋回波与三维梯度回波序列
前瞻性纳入150名受试者,在3台不同厂商3T扫描仪上比较常规与加速深度学习重建(Accel-DL)脑MRI的二维T1/T2加权和三维梯度回波序列,Accel-DL平均缩短扫描时间39.4%,整体图像质量、结构勾勒和伪影评分改善,SNR和CNR升高,体积测量除丘脑等深部灰质外无显著差异,白质高信号分割除白质皮层病灶外无显著差异。
要点
- Accel-DL使脑MRI平均扫描时间缩短39.4%(范围24.2%-51.3%)。
- 整体图像质量评分Accel-DL 3.78±0.71 vs 常规3.36±0.61,P<0.001。
- 体积测量98.2%的相关区域无显著差异,丘脑等深部灰质除外。
核心结论
- Accel-DL在自旋回波和梯度回波序列上均大幅缩短扫描时间并改善脑MRI质量,且不损害体积测量(包括病灶定量)。
研究设计与样本
- 前瞻性研究,纳入150名受试者(51名男性,平均年龄57.3±16.2岁),每组50名分别使用3台不同厂商的3T扫描仪,比较常规与Accel-DL的二维T1/T2加权和三维梯度回波序列,Accel-DL采用优化扫描参数缩短时间并用U-Net软件将欠采样k空间数据重建为高质量图像,由4名神经放射科医生评估。
关键影像表现/征象
- Accel-DL整体图像质量(3.78±0.71 vs 3.36±0.61,P<0.001)、结构勾勒(2.47±0.61 vs 2.35±0.62,P<0.001)和伪影(3.73±0.72 vs 3.71±0.69,P=0.016)评分均优于常规MRI,SNR(82.0±23.1 vs 31.4±10.8,P=0.02)和CNR(12.4±4.1 vs 4.4±11.2,P=0.02)升高。
诊断标准与关键数值
- 采用Likert 5分和3分量表评估整体图像质量、结构勾勒和伪影;读者间一致性Fleiss kappa为0.34-0.50(一般至中等);Bland-Altman分析显示98.2%的相关区域体积测量无显著差异,仅丘脑等深部灰质例外;白质高信号6类病灶中5类分割无显著差异,仅白质皮层病灶例外(r=0.64±0.29)。
临床应用与阅片要点
- Accel-DL可缩短脑MRI扫描时间并改善图像质量,体积测量和白质高信号分割结果与常规MRI基本一致,但深部灰质(包括丘脑)体积测量和白质皮层病灶分割可能存在差异。
局限性
- 读者间一致性为一般至中等(κ=0.34-0.50)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To prospectively evaluate the effect of accelerated deep learning-based reconstruction (Accel-DL) on improving brain magnetic resonance imaging (MRI) quality and reducing scan time compared to that in conventional MRI.
MATERIALS AND METHODS: This study included 150 participants (51 male; mean age 57.3 ± 16.2 years). Each group of 50 participants was scanned using one of three 3T scanners from three different vendors. Conventional and Accel-DL MRI images were obtained from each participant and compared using 2D T1- and T2-weighted and 3D gradient-echo sequences. Accel-DL acquisition was achieved using optimized scan parameters to reduce the scan time, with the acquired images reconstructed using U-Net-based software to transform low-quality, undersampled k-space data into high-quality images. The scan times of Accel-DL and conventional MRI methods were compared. Four neuroradiologists assessed the overall image quality, structural delineation, and artifacts using Likert scale (5- and 3-point scales). Inter-reader agreement was assessed using Fleiss' kappa coefficient. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated, and volumetric quantification of regional structures and white matter hyperintensities (WMHs) was performed.
RESULTS: Accel-DL showed a mean scan time reduction of 39.4% (range, 24.2%-51.3%). Accel-DL improved overall image quality (3.78 ± 0.71 vs. 3.36 ± 0.61, P < 0.001), structure delineation (2.47 ± 0.61 vs. 2.35 ± 0.62, P < 0.001), and artifacts (3.73 ± 0.72 vs. 3.71 ± 0.69, P = 0.016). Inter-reader agreement was fair to substantial (κ = 0.34-0.50). SNR and CNR increased in Accel-DL (82.0 ± 23.1 vs. 31.4 ± 10.8, P = 0.02; 12.4 ± 4.1 vs. 4.4 ± 11.2, P = 0.02). Bland-Altman plots revealed no significant differences in the volumetric measurements of 98.2% of the relevant regions, except in the deep gray matter, including the thalamus. Five of the six lesion categories showed no significant differences in WMH segmentation, except for leukocortical lesions (r = 0.64 ± 0.29).
CONCLUSION: Accel-DL substantially reduced the scan time and improved the quality of brain MRI in both spin-echo and gradient-echo sequences without compromising volumetry, including lesion quantification.
引用
- Choi KS, Park C, Lee JY, et al. Prospective Evaluation of Accelerated Brain MRI Using Deep Learning-Based Reconstruction: Simultaneous Application to 2D Spin-Echo and 3D Gradient-Echo Sequences. Korean J Radiol. 2025. PMID: 39780631. doi:10.3348/kjr.2024.0653
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。