IDH突变伴1p/19q共缺失少突胶质瘤的皮层高灌注征与组织学皮层血管密度相关
该回顾性研究纳入25例病理证实的IDH突变伴1p/19q共缺失少突胶质瘤成人患者,采用背景抑制伪连续动脉自旋标记成像判断皮层高灌注征,并用CD31免疫组化定量皮层血管密度。结果显示皮层高灌注征阳性组血管数目和相对血管密度均高于阴性组,而CNS WHO 2级与3级间该征出现频率及血管密度均无显著差异。
要点
- ASL皮层高灌注征阳性提示肿瘤影响皮层血管密度更高。
- 该征在CNS WHO 2级与3级少突胶质瘤间出现频率无显著差异。
- 判读时应选择无显著对比增强的肿瘤影响皮层区域。
核心结论
- ASL上皮层高灌注征在IDH突变伴1p/19q共缺失少突胶质瘤中与组织学皮层血管密度相关,且该征在此类肿瘤中较IDH野生型弥漫性胶质瘤或IDH突变型星形细胞瘤更常见。
研究设计与样本
- 回顾性研究,纳入25例病理证实的IDH突变伴1p/19q共缺失少突胶质瘤成人患者,采用背景抑制伪连续动脉自旋标记技术,以CD31免疫组化标记血管内皮细胞作为参考标准。
关键影像表现/征象
- 皮层高灌注征阳性的判定靶点为常规MRI上无显著对比增强的肿瘤影响皮层。
- 皮层高灌注征阳性组血管数目高于阴性组(p=0.016)。
- 皮层高灌注征阳性组相对血管密度高于阴性组(p=0.005)。
诊断标准与关键数值
- 皮层高灌注征阳性组与阴性组比较:血管数目p=0.016,相对血管密度p=0.005。
- CNS WHO 2级与3级间皮层高灌注征出现频率无显著差异(p=1.00)。
- CNS WHO 2级与3级间血管数目无显著差异(p=0.121),相对血管密度无显著差异(p=0.475)。
临床应用与阅片要点
- 在ASL减影图像上评估肿瘤影响但无显著对比增强的皮层是否出现高灌注征。
- 该征阳性可能与更高的组织学皮层血管密度相关,但CNS WHO分级间出现频率无显著差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: The cortical high-flow sign has been more commonly reported in oligodendroglioma, IDH-mutant and 1p/19q-codeleted (ODG IDHm-codel) compared to diffuse glioma with IDH-wildtype or astrocytoma, IDH-mutant. Besides tumor types, higher grades of glioma might also contribute to the cortical high flow. Therefore, we investigated whether the histological cortical vascular density or CNS WHO grade was associated with the cortical high-flow sign in patients with ODG IDHm-codel.
MATERIALS AND METHODS: This retrospective study consisted of pathologically confirmed 25 adult patients with ODG IDHm-codel. We implemented pseudo-continuous arterial spin labeling technique with background suppression. Subtraction images were generated from paired control and label images. Tumor-affecting cortices without intense contrast enhancement on conventional MR imaging were targeted for the determination of the cortical high-flow sign. Immunohistochemical staining of CD31 antibody was performed for the identification of vascular endothelial cells. A microscopic field of the most intense vascularization was captured in each specimen. The vessel number and the relative vascular density (%Vessel) were compared between the positive cortical high-flow sign (CHFS+) and the negative cortical high-flow sign (CHFS-) groups using the Mann-Whitney U test. Second, Fisher's exact test was used to compare the difference between the presence or absence of cortical high-flow sign and CNS WHO grades. Finally, the vessel number and %Vessel were compared between the CNS WHO grade 2 and grade 3 using the Mann-Whitney U test.
RESULTS: The vessel number and %Vessel were higher in patients with the CHFS+ group than in patients with CHFS- group (p = 0.016 and p = 0.005, respectively). We observed no significant differences (p = 1.00) in the frequency of cortical high-flow sign between the CNS WHO grade 2 and grade 3. In addition, no significant differences are found in the vessel number and %Vessel between the CNS WHO grade 2 and grade 3 (p = 0.121 and p = 0.475, respectively).
CONCLUSION: The cortical high-flow sign on ASL, which is more commonly found in ODG IDHm-codel than in diffuse glioma with IDH-wildtype or astrocytoma, is associated with the histological cortical vascular density in patients with ODG IDHm-codel.
引用
- Yamashita K, Murayama R, Itoyama M, et al. The cortical high-flow sign in oligodendroglioma, IDH-mutant and 1p/19q-codeleted is correlated with histological cortical vascular density. Neuroradiology. 2025. PMID: 39831960. doi:10.1007/s00234-024-03538-1