T2加权自旋回波不可用时b0-DWI分析对空洞性腔隙灶诊断的附加价值
回顾性纳入306例≥65岁、有FLAIR和b0-DWI但无T2-SE的脑MRI患者,149例(48.7%)见至少一个腔隙灶,其中33例(10.8%)仅在b0-DWI检出,20例(6.5%)报告未提及;b0-DWI腔隙灶诊断的观察者间一致性良好(kappa=0.717)。作者认为联合FLAIR与b0-DWI可提高空洞性腔隙灶检出。
要点
- 10.8%的空洞性腔隙灶仅见于b0-DWI,FLAIR上不可见。
- 6.5%的b0-DWI腔隙灶在神经影像报告中未提及。
- b0-DWI腔隙灶诊断观察者间一致性良好(kappa=0.717)。
核心结论
- 本研究中10.8%的b0-DWI腔隙灶在FLAIR上不可见,6.5%在神经影像报告中被提及;联合FLAIR与b0-DWI可提高空洞性腔隙灶检出并有助于血管预防。
研究设计与样本
- 回顾性纳入≥65岁因各种指征行脑MRI(1.5 T或3 T)、包含FLAIR和b0-DWI但无T2-SE的患者,排除多发性硬化、缺少b0-DWI或MRI质量差者,共306例;两名放射科医师独立分析所有b0-DWI序列后再分析FLAIR。
关键影像表现/征象
- 149例(48.7%)至少见一个腔隙灶:幕上54例(36.2%)、幕下32例(21.5%)、两者均有63例(42.3%)。
- 33例(10.8%)腔隙灶仅见于b0-DWI(b0-DWI腔隙灶),其中5例(1.6%)无血管危险因素。
- b0-DWI腔隙灶中幕上15例(45.5%)、幕下9例(27.3%)、两者均有9例(27.3%),28例(84.8%)伴白质病变。
- 119例(79.9%)有血管危险因素,135例(90.6%)有白质病变。
诊断标准与关键数值
- b0-DWI腔隙灶诊断观察者间一致性良好:一致率95.6%,kappa=0.717,95%CI [0.568-0.869]。
- 白质病变采用Fazekas量表评估。
临床应用与阅片要点
- T2-SE不可用时,阅片应同时结合FLAIR与b0-DWI以检出空洞性腔隙灶。
- b0-DWI腔隙灶中20例(6.5%)在报告中未提及,提示报告时需关注b0-DWI所见的腔隙灶。
局限性
- 原文为回顾性研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Silent brain infarcts, sometimes appearing as incidental lacunes in patients with unknown history of vascular event, are linked to dementia, gait disturbances and depression. We observed that some cavitating lacunes were only visible on b0-diffusion-weighted-imaging (b0-DWI: T2-weighted without diffusion gradients) when T2-weighted-spin-echo (T2-SE) was unavailable. We aimed to evaluate the additional value of b0-DWI in detecting cavitating lacunes.
METHODS: We retrospectively included patients aged ≥ 65 years who underwent brain MRI (1.5 T or 3 T) for various indications, with FLAIR (Fluid Attenuated Inversion Recovery) and b0-DWI, without T2-SE. Patients with multiple sclerosis, lacking b0-DWI or with low-quality MRI were excluded. Vascular risk factors, white matter lesions (Fazekas scale) and mention of lacune in the radiology report were inquired. Two radiologists independently analyzed all b0-DWI sequences, followed by FLAIR.
RESULTS: Among 306 subjects, at least one lacune was observed in 149 (48.7 %): 54 (36.2 %) supratentorial, 32 (21.5 %) infratentorial and 63 (42.3 %) both. Of these, 119 (79.9 %) had vascular risk factors and 135 (90.6 %) had white matter lesions. 33 (10.8 %) were exclusively detected on b0-DWI (b0-DWI-lacunes), of which 5 (1.6 %) without vascular factor, and 20 (6.5 %) were unmentioned in the report. Among b0-DWI-lacunes, 15 (45.5 %) were supratentorial, 9 (27.3 %) infratentorial and 9 (27.3 %) both, with 28 (84.8 %) associated with white matter lesions. Inter-rater reliability for b0-DWI-lacunes diagnosis was good (95.6 % agreement, kappa = 0.717, CI95% [0.568-0.869]).
CONCLUSION: In our study, 10.8% b0-DWI-lacunes were not visible on FLAIR, and 6.5% were unmentioned in the neuroradiology report. Examining FLAIR alongside b0-DWI improves diagnostic performance for cavitating lacune detection and contributes to vascular prevention.
引用
- Leung Kune Chong C, Aignatoaie A, Salem A, et al. The added value of b0-DWI analysis in the diagnosis of cavitating lacunes when T2-weighted spin-echo is unavailable. Eur J Radiol. 2025. PMID: 39826156. doi:10.1016/j.ejrad.2025.111924
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。