文献速递神经MR

两种加速高分辨率3D FLAIR技术(Wave-CAIPI与深度学习SPACE)的图像质量评估与白质高信号定量比较

Image quality assessment and white matter hyperintensity quantification in two accelerated high-resolution 3D FLAIR techniques: Wave-CAIPI and deep learning-based SPACE.
PubMed 文献 · Clin Radiol · 2024-12-19

回顾性分析123例同时行DL-SPACE与Wave-CAIPI FLAIR脑成像的受试者,两名放射科医师用Likert量表定性评分,并定量计算SNR、CNR及自动量化白质高信号体积。DL-SPACE FLAIR在精细结构显示、伪影程度、整体图像质量及SNR、CNR上均显著优于Wave-CAIPI FLAIR,且检出的脑室旁和深部白质高信号体积更大。

要点

  • DL-SPACE FLAIR的精细结构显示评分显著高于Wave-CAIPI FLAIR(P<0.001)。
  • DL-SPACE FLAIR的伪影程度显著低于Wave-CAIPI FLAIR(P<0.001)。
  • DL-SPACE FLAIR检出的脑室旁和深部白质高信号体积均显著大于Wave-CAIPI FLAIR。

核心结论

  • 在相同采集时间下,DL-SPACE FLAIR技术产生的图像质量、SNR和CNR均优于Wave-CAIPI FLAIR技术。

研究设计与样本

  • 回顾性研究,共纳入123例接受DL-SPACE与Wave-CAIPI FLAIR脑成像的受试者,由两名放射科医师基于Likert量表进行定性评分,并定量计算SNR、CNR及自动量化白质高信号体积。

关键影像表现/征象

  • DL-SPACE FLAIR的精细结构显示显著更高(P<0.001),伪影程度显著更低(P<0.001),整体图像质量显著更高(P=0.001)。
  • DL-SPACE FLAIR的正常表现白质SNR为43.95,病灶SNR为31.35;Wave-CAIPI FLAIR分别为31.6和21.28(均P<0.001)。
  • DL-SPACE FLAIR的白质高信号CNR为11.34,Wave-CAIPI FLAIR为8.22(P<0.001)。
  • DL-SPACE FLAIR的脑室旁白质高信号体积为1.91±4.69,Wave-CAIPI FLAIR为1.54±4.18(P<0.001);深部白质高信号体积分别为0.26±0.42和0.23±0.38(P=0.002)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To compare the image quality obtained using two accelerated high-resolution 3D fluid-attenuated inversion recovery (FLAIR) techniques for the brain-deep learning-reconstruction SPACE (DL-SPACE) and Wave-CAIPI FLAIR.

MATERIALS AND METHODS: A total of 123 participants who underwent DL-SPACE and Wave-CAIPI FLAIR brain imaging were retrospectively reviewed. In a qualitative analysis, two radiologists rated the quality of each image, including the overall image quality, artifacts, sharpness, fine-structure conspicuity, and lesion conspicuity based on Likert scales. In a quantitative analysis, the signal-to-noise ratio (SNR) for the normal-appearing white matter (NAWM) and lesion and the contrast-to-noise ratio (CNR) for a lesion were calculated and compared. Moreover, the volumes of white matter hyperintensities (WMHs) obtained with the two techniques were automatically quantified and compared.

RESULTS: The DL-SPACE FLAIR technique demonstrated a significantly higher fine-structure conspicuity (P < 0.001), lower degree of artifacts (P < 0.001) and higher overall image quality (P = 0.001). The mean SNR values were significantly higher with the DL-SPACE FLAIR technique (NAWM, 43.95 vs. 31.6; lesion, 31.35 vs. 21.28; all, P < 0.001). Additionally, the mean CNR of the WMH was significantly higher with the DL-SPACE FLAIR technique (11.34 vs. 8.22; P < 0.001). The periventricular and deep WMH volumes were significantly larger with the DL-SPACE FLAIR technique (1.91 ± 4.69 vs. 1.54 ± 4.18; P < 0.001 and 0.26 ± 0.42 vs. 0.23 ± 0.38; P = 0.002, respectively).

CONCLUSION: The DL-SPACE FLAIR technique produced images with superior quality, SNR and CNR compared with the Wave-CAIPI FLAIR technique with the same acquisition time.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Jung HK, Choi Y, Kim S, et al. Image quality assessment and white matter hyperintensity quantification in two accelerated high-resolution 3D FLAIR techniques: Wave-CAIPI and deep learning-based SPACE. Clin Radiol. 2024. PMID: 39842179. doi:10.1016/j.crad.2024.106783

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。