文献速递神经MR

对比增强3D黑血TSE序列较增强后3D T1 GRE序列提高脑转移瘤检出:一项1.5-T MRI比较研究

Improved detection of brain metastases using contrast-enhanced 3D black-blood TSE sequences compared to post-contrast 3D T1 GRE: a comparative study on 1.5-T MRI.
PubMed 文献 · Eur Radiol · 2025-01-22

该回顾性研究纳入107例疑似或随访脑转移瘤患者,在同一1.5-T MRI扫描仪上采集增强后3D T1 GRE与3D黑血序列,由两名神经放射科医生独立评估转移瘤数目、大小和位置。黑血序列检出脑转移瘤数量显著更多,尤其<5 mm小病灶,且85%患者中病灶 conspicuity 更佳;≥5 mm病灶两组无显著差异。

要点

  • 1.5-T MRI增强后3D黑血TSE序列检出脑转移瘤总数显著多于3D T1 GRE序列,尤其<5 mm小病灶。
  • ≥5 mm转移瘤检出两序列无显著差异。
  • 85%患者中黑血序列对转移瘤的显示清晰度更佳。

核心结论

  • 在1.5-T MRI上,增强后3D T1 TSE黑血序列较标准3D T1 GRE序列可改善脑转移瘤检出,尤其小病灶。

研究设计与样本

  • 回顾性分析,2022年5月至2023年9月共183例疑似或随访脑转移瘤患者,最终107例纳入分析;同一扫描仪采集增强后3D T1 GRE与3D黑血序列,采集时间相近;两名神经放射科医生独立评估。

关键影像表现/征象

  • 黑血序列检出脑转移瘤数量显著多于3D T1 GRE序列(p < 0.05),尤其<5 mm小病灶。
  • ≥5 mm转移瘤检出两序列无显著差异。
  • 85%患者中黑血序列对转移瘤的显示清晰度更佳。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Brain metastases are the most common intracranial malignancy in adults, and their detection is crucial for treatment planning. Post-contrast 3D T1 gradient-recalled echo (GRE) sequences are commonly used for this purpose, but contrast-enhanced 3D T1 turbo spin-echo (TSE) sequences with motion-sensitized driven-equilibrium (MSDE) technique ("black blood") may offer improved detection. This study aimed to compare the effectiveness of contrast-enhanced 3D black blood sequences to standard 3D T1 GRE sequences in detecting brain metastases on a 1.5-T MRI.

MATERIALS AND METHODS: A retrospective analysis of 183 patients with suspected or follow-up brain metastases between May 2022 and September 2023 was conducted. Among these patients, 107 were included in the final analysis. Both post-contrast 3D T1 GRE and 3D black blood sequences were acquired on the same scanner with similar acquisition times. Two neuroradiologists independently evaluated the images for the number, size, and location of metastases. Interobserver variability and statistical analysis were performed.

RESULTS: Among the 107 patients (mean age 60.8 years ± 13.2 years; 55 males, 52 females), 3D black blood sequences detected a significantly higher number of brain metastases, particularly small lesions (< 5 mm), compared to 3D T1 GRE sequences (p < 0.05). There was no significant difference in detecting large metastases (≥ 5 mm) between the sequences. In addition, the black blood sequences provided better conspicuity of metastases in the majority of patients (85%).

CONCLUSION: Contrast-enhanced 3D T1 TSE with MSDE ("black blood") sequences offer improved detection of brain metastases, especially small lesions, on 1.5-T MRI compared to standard 3D T1 GRE sequences.

KEY POINTS: Question Accurate identification of the number and location of brain metastases using MRI is essential for planning and managing effective treatment. Findings Contrast-enhanced 3D T1 TSE black blood sequences detected significantly more small brain metastases than standard 3D T1 GRE sequences on 1.5-T MRI. Clinical relevance The use of 3D black blood sequences on 1.5-T MRI may have the potential to improve the accuracy of detection of brain metastases, leading to better treatment planning and potentially improved patient outcomes.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Chen Zhou ZH, Salvador Álvarez E, Hilario A, et al. Improved detection of brain metastases using contrast-enhanced 3D black-blood TSE sequences compared to post-contrast 3D T1 GRE: a comparative study on 1.5-T MRI. Eur Radiol. 2025. PMID: 39841203. doi:10.1007/s00330-025-11363-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。