基于开源算法训练的T1和T2 MRI序列生成腰椎AI合成STIR影像
研究用1817例腰椎MRI训练开源生成对抗网络,由T1和T2序列合成STIR容积,并由3名放射科医师盲法随机评估。合成图像质量等于或优于采集图像者占77%,运动伪影等同或减少者占78%;常见病变阳性预测值高(75%-100%)但敏感度较低(0%-67%)。
要点
- 合成STIR在77%的测试患者中质量等于或优于采集图像。
- 合成STIR在78%的测试患者中运动伪影等同或减少。
- 合成STIR对常见病变阳性预测值75%-100%,敏感度仅0%-67%。
核心结论
- 开源可复现方法能生成高质量合成STIR容积并复现许多重要病变,可能成为加快影像检查流程的手段。
研究设计与样本
- 共积累1817例含矢状位T1、T2和STIR序列的MRI检查,随机分为训练集、验证集和测试集;训练生成对抗网络以T1和T2容积为输入合成STIR容积,用验证集优化后应用于测试集;由3名肌肉骨骼影像和神经放射学专科放射科医师以盲法随机方式独立评估采集与合成测试集容积。
关键影像表现/征象
- 最佳模型采用强调前景像素的定制损失函数,结构相似性影像指标为0.842,平均绝对误差为0.028,峰值信噪比为26.367。
- 放射科医师能够区分合成与采集容积,但合成容积在77%的测试患者中质量等于或优于采集容积。
- 合成容积在78%的测试患者中运动伪影等同或减少。
诊断标准与关键数值
- 常见病变方面,合成容积的阳性预测值为75%-100%,敏感度较低,为0%-67%。
临床应用与阅片要点
- 合成STIR容积阳性预测值高(75%-100%)但敏感度低(0%-67%),阅片时需注意其对常见病变的检出能力有限。
- 放射科医师能够区分合成与采集容积,提示合成图像在临床使用前需评估其可识别性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Lumbar spine MRIs can be time consuming, stressful for patients, and costly to acquire. In this work, we train and evaluate open-source generative adversarial network (GAN) to create synthetic lumbar spine MRI STIR volumes from T1 and T2 sequences, providing a proof-of-concept that could allow for faster MRI examinations.
MATERIALS AND METHODS: A total of 1817 MRI examinations with sagittal T1, T2, and STIR sequences were accumulated and randomly divided into training, validation, and test sets. A GAN was trained to create synthetic STIR volumes by using the T1 and T2 volumes as inputs, optimized with the validation set, and then applied to the test set. Acquired and synthetic test set volumes were independently evaluated in a blinded, randomized fashion by 3 radiologists specializing in musculoskeletal imaging and neuroradiology. Readers assessed image quality, motion artifacts, perceived likelihood of the volume being acquired or synthetic, and the presence of 7 pathologies.
RESULTS: The optimal model leveraged a customized loss function that accentuated foreground pixels, achieving a structural similarity imaging metric of 0.842, mean absolute error of 0.028, and peak signal-to-noise ratio of 26.367. Radiologists could distinguish synthetic from acquired volumes; however, the synthetic volumes were of equal or better quality in 77% of test patients and demonstrated equivalent or decreased motion artifacts in 78% of test patients. For common pathologies, the synthetic volumes had high positive predictive value (75%-100%) but lower sensitivity (0%-67%).
CONCLUSIONS: This work links objective computer vision performance metrics and subject clinical evaluation of synthetic spine MRIs by using open-source and reproducible methodologies. High-quality synthetic volumes are generated, reproducing many important pathologies and demonstrating a potential means for expediting imaging protocols.
引用
- Santilli AML, Fontana MA, Xia EE, et al. AI-Generated Synthetic STIR of the Lumbar Spine from T1 and T2 MRI Sequences Trained with Open-Source Algorithms. AJNR Am J Neuroradiol. 2025. PMID: 39805669. doi:10.3174/ajnr.A8512