多参数非增强磁共振成像在胶质瘤分级及与IDH突变状态相关性中的诊断效能
本研究纳入术后病理确诊的胶质瘤患者,评估非增强MRI定量参数(rAPTW、rCBF、ADC)在胶质瘤分级和IDH突变状态相关性中的诊断效能。结果显示3D-APTW成像区分低级别与高级别胶质瘤的AUC为0.930、敏感度91.2%、特异度87.5%,优于DWI和3D-pCASL成像,且联合应用可提升诊断效能;APTW、rAPTW、CBF、rCBF在IDH突变型组显著低于IDH野生型组,ADC在IDH突变型组显著高于IDH野生型组。
要点
- 3D-APTW成像区分LGG与HGG的AUC为0.930,敏感度91.2%,特异度87.5%,优于DWI和3D-pCASL成像。
- 将3D-APTW成像加入3D-pCASL成像或DWI后,两种序列的诊断效能均提升。
- APTW、rAPTW、CBF、rCBF在IDH突变型组显著低于IDH野生型组,ADC在IDH突变型组显著高于IDH野生型组。
核心结论
- 3D-APTW成像在胶质瘤分级方面诊断效能优于DWI或3D-pCASL成像,且对两者区分LGG与HGG有附加价值;3D-APTW、3D-pCASL和DWI成像可用于区分IDH突变型与IDH野生型组。
研究设计与样本
- 纳入术后病理确诊的胶质瘤患者,采用rAPTW、rCBF和ADC定量参数进行胶质瘤分级及IDH突变状态相关性分析,MRI参数比较采用独立样本t检验,诊断效能采用ROC曲线及AUC评估和比较。
关键影像表现/征象
- rAPTW信号和rCBF值在高级别胶质瘤(HGG)中显著高于低级别胶质瘤(LGG)。
- ADC值在HGG中显著低于LGG。
- APTW、rAPTW、CBF和rCBF值在IDH突变型组显著低于IDH野生型组。
- ADC值在IDH突变型组显著高于IDH野生型组。
诊断标准与关键数值
- 3D-APTW成像区分LGG与HGG的AUC为0.930,敏感度91.2%,特异度87.5%。
- 与3D-pCASL成像和DWI相比,3D-APTW成像区分LGG与HGG的诊断效能最佳。
- 将3D-APTW成像加入3D-pCASL成像或DWI后,两种序列的诊断效能均提升。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate the diagnostic performance of nonenhanced magnetic resonance imaging (MRI) in grading glioma and correlating isocitrate dehydrogenase (IDH) mutation status.
MATERIALS AND METHODS: Patients with diagnoses confirmed by postoperative pathology were enrolled. Quantitative parameters, including the relative amide proton transfer-weighted (rAPTW), relative cerebral blood flow (CBF), and apparent diffusion coefficient (ADC) were applied to grade gliomas and correlate IDH mutation status. MRI parameters were compared with an independent-sample t-test. The diagnostic performance was assessed and compared with a receiver operating characteristic (ROC) curve and the area under the ROC curve (AUC).
RESULTS: The rAPTW signal and rCBF values were significantly higher in high-grade gliomas (HGG) than in low-grade glioma (LGG), whereas ADC values were significantly lower in HGG than in LGG. Compared with 3D-pCASL imaging and diffusion-weighted imaging (DWI), 3D-APTW imaging had the best diagnostic performance in distinguishing LGG from HGG, with an AUC of 0.930, a sensitivity of 91.2% and a specificity of 87.5%. By adding 3D-APTW imaging to 3D-pCASL imaging, or DWI, the diagnostic performance of both sequences increased. Furthermore, APTW, rAPTW, CBF, and rCBF values in the IDH mutant-type (IDH-mut) group were significantly lower than those in the IDH wild-type (IDH-wt) group, ADC values were significantly higher in IDH-mut group than in IDH-wt group.
CONCLUSION: 3D-APTW imaging demonstrated better diagnostic performance than DWI or 3D-pCASL imaging in grading gliomas. Moreover, 3D-APTW imaging had added value in addition to both 3D-pCASL imaging and DWI in distinguishing LGG from HGG. 3D-APTW, 3D-pCASL, and DWI imaging could be used to discriminate between IDH-mut and IDH-wt group.
引用
- Hou H, Yu J, Diao Y, et al. Diagnostic performance of multiparametric nonenhanced magnetic resonance imaging (MRI) in grading glioma and correlating IDH mutation status. Clin Radiol. 2024. PMID: 39837107. doi:10.1016/j.crad.2024.106791
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。