文献速递神经MR

多参数非增强磁共振成像在胶质瘤分级及与IDH突变状态相关性中的诊断效能

Diagnostic performance of multiparametric nonenhanced magnetic resonance imaging (MRI) in grading glioma and correlating IDH mutation status.
PubMed 文献 · Clin Radiol · 2024-12-26

本研究纳入术后病理确诊的胶质瘤患者,评估非增强MRI定量参数(rAPTW、rCBF、ADC)在胶质瘤分级和IDH突变状态相关性中的诊断效能。结果显示3D-APTW成像区分低级别与高级别胶质瘤的AUC为0.930、敏感度91.2%、特异度87.5%,优于DWI和3D-pCASL成像,且联合应用可提升诊断效能;APTW、rAPTW、CBF、rCBF在IDH突变型组显著低于IDH野生型组,ADC在IDH突变型组显著高于IDH野生型组。

要点

  • 3D-APTW成像区分LGG与HGG的AUC为0.930,敏感度91.2%,特异度87.5%,优于DWI和3D-pCASL成像。
  • 将3D-APTW成像加入3D-pCASL成像或DWI后,两种序列的诊断效能均提升。
  • APTW、rAPTW、CBF、rCBF在IDH突变型组显著低于IDH野生型组,ADC在IDH突变型组显著高于IDH野生型组。

核心结论

  • 3D-APTW成像在胶质瘤分级方面诊断效能优于DWI或3D-pCASL成像,且对两者区分LGG与HGG有附加价值;3D-APTW、3D-pCASL和DWI成像可用于区分IDH突变型与IDH野生型组。

研究设计与样本

  • 纳入术后病理确诊的胶质瘤患者,采用rAPTW、rCBF和ADC定量参数进行胶质瘤分级及IDH突变状态相关性分析,MRI参数比较采用独立样本t检验,诊断效能采用ROC曲线及AUC评估和比较。

关键影像表现/征象

  • rAPTW信号和rCBF值在高级别胶质瘤(HGG)中显著高于低级别胶质瘤(LGG)。
  • ADC值在HGG中显著低于LGG。
  • APTW、rAPTW、CBF和rCBF值在IDH突变型组显著低于IDH野生型组。
  • ADC值在IDH突变型组显著高于IDH野生型组。

诊断标准与关键数值

  • 3D-APTW成像区分LGG与HGG的AUC为0.930,敏感度91.2%,特异度87.5%。
  • 与3D-pCASL成像和DWI相比,3D-APTW成像区分LGG与HGG的诊断效能最佳。
  • 将3D-APTW成像加入3D-pCASL成像或DWI后,两种序列的诊断效能均提升。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate the diagnostic performance of nonenhanced magnetic resonance imaging (MRI) in grading glioma and correlating isocitrate dehydrogenase (IDH) mutation status.

MATERIALS AND METHODS: Patients with diagnoses confirmed by postoperative pathology were enrolled. Quantitative parameters, including the relative amide proton transfer-weighted (rAPTW), relative cerebral blood flow (CBF), and apparent diffusion coefficient (ADC) were applied to grade gliomas and correlate IDH mutation status. MRI parameters were compared with an independent-sample t-test. The diagnostic performance was assessed and compared with a receiver operating characteristic (ROC) curve and the area under the ROC curve (AUC).

RESULTS: The rAPTW signal and rCBF values were significantly higher in high-grade gliomas (HGG) than in low-grade glioma (LGG), whereas ADC values were significantly lower in HGG than in LGG. Compared with 3D-pCASL imaging and diffusion-weighted imaging (DWI), 3D-APTW imaging had the best diagnostic performance in distinguishing LGG from HGG, with an AUC of 0.930, a sensitivity of 91.2% and a specificity of 87.5%. By adding 3D-APTW imaging to 3D-pCASL imaging, or DWI, the diagnostic performance of both sequences increased. Furthermore, APTW, rAPTW, CBF, and rCBF values in the IDH mutant-type (IDH-mut) group were significantly lower than those in the IDH wild-type (IDH-wt) group, ADC values were significantly higher in IDH-mut group than in IDH-wt group.

CONCLUSION: 3D-APTW imaging demonstrated better diagnostic performance than DWI or 3D-pCASL imaging in grading gliomas. Moreover, 3D-APTW imaging had added value in addition to both 3D-pCASL imaging and DWI in distinguishing LGG from HGG. 3D-APTW, 3D-pCASL, and DWI imaging could be used to discriminate between IDH-mut and IDH-wt group.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Hou H, Yu J, Diao Y, et al. Diagnostic performance of multiparametric nonenhanced magnetic resonance imaging (MRI) in grading glioma and correlating IDH mutation status. Clin Radiol. 2024. PMID: 39837107. doi:10.1016/j.crad.2024.106791

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。