利用体素内不相干运动MRI成像缺血半暗带的方法
在犬大脑中动脉闭塞模型中,比较IVIM局部定量脑血流量(local-qCBF)与DSC局部qCBF在半暗带的一致性,并评估两者预测最终梗死体积的能力。结果显示IVIM local-qCBF与DSC local-qCBF强相关,两者均能较好预测最终梗死体积,而DSC标准qCBF预测能力较弱;IVIM PWI/DWI比值与梗死增长相关。
要点
- IVIM local-qCBF与DSC local-qCBF在非梗死同侧区域强相关,可替代性测量局部血流。
- IVIM local-qCBF和DSC local-qCBF均能强预测最终梗死体积,DSC标准qCBF预测较弱。
- IVIM PWI/DWI比值与梗死增长相关,WTT与DSC MTT相关。
核心结论
- 无对比剂IVIM测量的local-qCBF及PWI/DWI不匹配可能纳入侧支循环信息,并改善对梗死增长的预测。
研究设计与样本
- 临床前犬大脑中动脉闭塞模型共8次实验,闭塞后30分钟行X线DSA量化原生侧支循环,部分实验用升压药和扩血管药增强侧支供血,闭塞后2.5小时行IVIM、DSC和DWI MRI,闭塞后2.5和4小时用DWI测量梗死体积。
诊断标准与关键数值
- 闭塞后2.5小时,非梗死同侧区域的IVIM local-qCBF与DSC local-qCBF强相关([公式:见原文])。
- IVIM local-qCBF与DSC standard-qCBF相关性较弱([公式:见原文])。
- DSC local-qCBF和IVIM local-qCBF均能强预测最终梗死体积([公式:见原文]),DSC standard-qCBF预测较弱([公式:见原文])。
- DSC local-qCBF和IVIM local-qCBF的低灌注病灶均以良好敏感度和相关性预测最终梗死体积([公式:见原文])。
- IVIM PWI/DWI比值与梗死增长相关([公式:见原文]),WTT与DSC MTT相关([公式:见原文])。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: In acute ischemic stroke, the amount of "local" CBF distal to the occlusion, ie, all blood flow, whether supplied antegrade or delayed and dispersed through the collateral network, may contain valuable information regarding infarct growth rate and treatment response. DSC processed with a local arterial input function (AIF) is one method of measuring local CBF (local-qCBF) and has been shown to correlate with collateral supply. Similarly, intravoxel incoherent motion MRI (IVIM) is "local," with excitation and readout in the same plane, and a potential alternative way to measure local-qCBF. This work compares IVIM local-qCBF against DSC local-qCBF in the ischemic penumbra, compares the measurement of perfusion-diffusion mismatch (PWI/DWI), and examines if local-qCBF may improve prediction of the final infarct.
MATERIALS AND METHODS: Eight experiments in a preclinical canine model of middle cerebral artery occlusion were performed. Native collateral circulation was quantified via x-ray DSA 30 minutes postocclusion, and collateral supply was subsequently enhanced in a subset of experiments with simultaneous pressor and vasodilator. IVIM, DSC, and DWI MRI were acquired 2.5 hours postocclusion. IVIM was postprocessed to return local-qCBF from fD*, water transport time (WTT) from D*, diffusion from D, and the PWI/DWI mismatch. These were compared with DSC parameters processed first with a standard global-AIF and then with a local-AIF. These DSC parameters included time-to-maximum, local MTT, standard-qCBF, local-qCBF, and PWI/DWI mismatch. Infarct volume was measured with DWI at 2.5 hours and 4 hours postocclusion.
RESULTS: Two and one-half hours postocclusion, IVIM local-qCBF in the noninfarcted ipsilateral territory correlated strongly with DSC local-qCBF ([Formula: see text]). Correlation was weaker between IVIM local-qCBF and DSC standard-qCBF ([Formula: see text]). DSC local-qCBF and IVIM local-qCBF in the noninfarcted ipsilateral territory both returned strong prediction of final infarct volume ([Formula: see text]). DSC standard-qCBF was a weaker predictor ([Formula: see text]). The hypoperfused lesion from DSC local-qCBF and from IVIM local-qCBF both predicted final infarct volume with good sensitivity and correlation ([Formula: see text]. The IVIM PWI/DWI ratio was correlated with infarct growth ([Formula: see text]), and WTT correlated with DSC MTT ([Formula: see text]).
CONCLUSIONS: Noncontrast IVIM measurement of local-qCBF and PWI/DWI mismatch may include collateral circulation and improve prediction of infarct growth.
引用
- Liu MM, Saadat N, Roth SP, et al. A Method for Imaging the Ischemic Penumbra with MRI Using Intravoxel Incoherent Motion. AJNR Am J Neuroradiol. 2025. PMID: 39805668. doi:10.3174/ajnr.A8656
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。