文献速递神经外周血管US

纳米液滴成像联合超声定位显微技术检测脑出血

Combined Nanodrops Imaging and Ultrasound Localization Microscopy for Detecting Intracerebral Hemorrhage.
PubMed 文献 · Ultrasound Med Biol · 2025-01-20

本研究在啮齿类动物模型中联合基于微泡的超声定位显微技术(ULM)与基于纳米液滴(ND)的血管渗漏成像,实现全脑微血管成像与出血灶同时检测。结果显示ND可在出血部位聚集并在聚焦超声激活后显示出血区域,ULM进一步揭示出血灶周围血管密度减低和血流速度下降的微血管损伤。作者认为该序贯联合方法对需要全脑检测活动性出血和微血管损伤的啮齿类卒中基础在体研究是有用的成像工具。

要点

  • 纳米液滴可在出血部位聚集,经聚焦超声激活后显示出血区域位置。
  • ULM可全脑显示脑血管微血管结构并识别出血灶周围微血管损伤。
  • 出血影响区域表现为血管密度减低和血流速度下降。

核心结论

  • 序贯ULM联合ND成像对需要全脑检测活动性出血和微血管损伤的啮齿类卒中基础在体研究是有用的成像工具。

研究设计与样本

  • 临床前在体动物研究,采用基于微泡的超声定位显微技术(ULM)联合基于纳米液滴(ND)的血管渗漏成像,在啮齿类动物模型中同时进行微血管成像与出血检测。

关键影像表现/征象

  • ND可在出血部位有效聚集,经聚焦超声束激活后显示出血区域位置。
  • ULM显示出血性卒中影响区域存在微血管损伤,表现为血管密度减低和血流速度下降。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Advanced imaging methods are crucial for understanding stroke mechanisms and discovering effective treatments to reduce bleeding and enhance recovery. In pre-clinical in vivo stroke imaging, MRI, CT and optical imaging are commonly used to evaluate stroke outcomes in rodent models. However, MRI and CT have limited spatial resolution for rodent brains, and optical imaging is hindered by limited imaging depth of penetration. Here we introduce a novel contrast-enhanced ultrasound imaging method to overcome these challenges and characterize intracerebral hemorrhage with unique insights.

METHODS: We combined microbubble-based ultrasound localization microscopy (ULM) and nanodrop (ND)-based vessel leakage imaging to achieve simultaneous microvascular imaging and hemorrhage detection. ULM maps brain-wide cerebral vasculature with high spatial resolution and identifies microvascular impairments around hemorrhagic areas. NDs are sub-micron liquid-core particles that can extravasate due to blood-brain barrier breakdown, serving as positive contrast agents to detect hemorrhage sites.

RESULTS: Our findings demonstrate that NDs could effectively accumulate in the hemorrhagic site and reveal the location of the bleeding areas upon activation by focused ultrasound beams. ULM further reveals the microvascular damage manifested in the form of reduced vascularity and decreased blood flow velocity across areas affected by the hemorrhagic stroke.

CONCLUSION: The results demonstrate that sequential ULM combined with ND imaging is a useful imaging tool for basic in vivo research in stroke with rodent models where brain-wide detection of active bleeding and microvascular impairment are essential.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Lin BZ, Fan AC, Wang Y, et al. Combined Nanodrops Imaging and Ultrasound Localization Microscopy for Detecting Intracerebral Hemorrhage. Ultrasound Med Biol. 2025. PMID: 39837748. doi:10.1016/j.ultrasmedbio.2025.01.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。