X线等效剂量光子计数探测器CT对肺气肿的评估:视觉评分与自动定量算法的评价
本研究前瞻性纳入101例患者,采用光子计数探测器CT行低剂量与X线剂量非增强扫描,评估视觉评分、低衰减容积(LAV)和深度学习算法估计肺气肿范围的可行性与效能。视觉评分在两种剂量间一致性良好(κ=0.70),深度学习模型在低剂量扫描中与视觉评分一致性较高(κ=0.65);但两种自动算法在X线剂量扫描中均显著高估肺气肿体积(P<0.001)。
要点
- X线剂量PCD-CT上视觉评分可可靠评估肺气肿严重程度,与低剂量扫描一致性良好(κ=0.70)。
- LAV阈值-950 HU与深度学习模型在X线剂量扫描中均显著高估肺气肿体积,深度学习模型更稳健。
- 深度学习模型在低剂量扫描中与视觉评分一致性(κ=0.65)高于LAV(κ=0.48)。
核心结论
- 在PCD-CT的X线等效剂量扫描上,视觉评分可可靠估计肺气肿严重程度;深度学习算法在低剂量扫描中与视觉评分一致性良好且相关性强,但深度学习和LAV算法在X线剂量扫描中均高估肺气肿范围。
研究设计与样本
- 前瞻性研究纳入101例患者,采用PCD-CT行非增强低剂量和胸部X线剂量扫描,由2名经验丰富的放射科医生独立评估图像质量、锐利度、噪声及Fleischner学会视觉肺气肿模式,并进行专家共识判读;随后使用阈值-950 HU的LAV算法和商用深度学习模型进行自动定量,并与视觉评分比较。
诊断标准与关键数值
- 视觉肺气肿模式按Fleischner学会定义分为无、微量、轻度、中度、融合性和晚期破坏性肺气肿;LAV算法采用-950 HU阈值;X线剂量扫描CT剂量指数(0.11±0.03 mGy)显著低于低剂量扫描(0.66±0.16 mGy,P<0.001);低剂量与X线剂量间视觉评分阅片者间一致性κ=0.83;两种剂量间视觉评分共识一致性κ=0.70,Spearman ρ=0.79;深度学习模型在低剂量扫描中与视觉评分一致性κ=0.65、Spearman ρ=0.64,LAV为κ=0.48、Spearman ρ=0.45;两种自动方法在X线剂量扫描中均显著高估肺气肿体积(P<0.001)。
临床应用与阅片要点
- 在PCD-CT X线等效剂量扫描上,视觉评分可用于可靠估计肺气肿严重程度;使用自动定量算法时需注意其在低剂量扫描中会高估肺气肿体积,深度学习模型较LAV更稳健。
局限性
- X线剂量扫描中微量肺气肿被低估。
- LAV和深度学习算法在X线剂量扫描中均显著高估肺气肿体积(P<0.001)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this study was to evaluate the feasibility and efficacy of visual scoring, low-attenuation volume (LAV), and deep learning methods for estimating emphysema extent in x-ray dose photon-counting detector computed tomography (PCD-CT), aiming to explore future dose reduction potentials.
METHODS: One hundred one prospectively enrolled patients underwent noncontrast low- and chest x-ray dose CT scans in the same study using PCD-CT. Overall image quality, sharpness, and noise, as well as visual emphysema pattern (no, trace, mild, moderate, confluent, and advanced destructive emphysema; as defined by the Fleischner Society), were independently assessed by 2 experienced radiologists for low- and x-ray dose images, followed by an expert consensus read. In the second step, automated emphysema quantification was performed using an established LAV algorithm with a threshold of -950 HU and a commercially available deep learning model for automated emphysema quantification. Automated estimations of emphysema extent were converted and compared with visual scoring ratings.
RESULTS: X-ray dose scans exhibited a significantly lower computed tomography dose index than low-dose scans (low-dose: 0.66 ± 0.16 mGy, x-ray dose: 0.11 ± 0.03 mGy, P < 0.001). Interreader agreement between low- and x-ray dose for visual emphysema scoring was excellent (κ = 0.83). Visual emphysema scoring consensus showed good agreement between low-dose and x-ray dose scans (κ = 0.70), with significant and strong correlation (Spearman ρ = 0.79). Although trace emphysema was underestimated in x-ray dose scans, there was no significant difference in the detection of higher-grade (mild to advanced destructive) emphysema ( P = 0.125) between the 2 scan doses. Although predicted emphysema volumes on x-ray dose scans for the LAV method showed strong and the deep learning model excellent significant correlations with predictions on low-dose scans, both methods significantly overestimated emphysema volumes on lower quality scans ( P < 0.001), with the deep learning model being more robust. Further, deep learning emphysema severity estimations showed higher agreement (κ = 0.65) and correlation (Spearman ρ = 0.64) with visual scoring for low-dose scans than LAV predictions (κ = 0.48, Spearman ρ = 0.45).
CONCLUSIONS: The severity of emphysema can be reliably estimated using visual scoring on CT scans performed with x-ray equivalent doses on a PCD-CT. A deep learning algorithm demonstrated good agreement and strong correlation with the visual scoring method on low-dose scans. However, both the deep learning and LAV algorithms overestimated emphysema extent on x-ray dose scans. Nonetheless, x-ray equivalent radiation dose scans may revolutionize the detection and monitoring of disease in chronic obstructive pulmonary disease patients.
引用
- Kerber B, Ensle F, Kroschke J, et al. Assessment of Emphysema on X-ray Equivalent Dose Photon-Counting Detector CT: Evaluation of Visual Scoring and Automated Quantification Algorithms. Invest Radiol. 2024. PMID: 39729642. doi:10.1097/RLI.0000000000001128
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。