文献速递技术与安全CT

患者量对多剂量对比剂注射器碘对比剂浪费的影响

Impact of Patient Volume on Iodinated Contrast Material Waste with Multidose Contrast Injectors.
PubMed 文献 · Acad Radiol · 2024-12-27

本研究在急诊CT单元为期一年、共12,290次扫描中评估多剂量碘对比剂注射器在不同日患者量下的浪费情况。多剂量注射器使年碘对比剂浪费较单剂量注射器减少86.1%,但日患者量低于20例时每患者平均浪费反而高于单剂量注射器。

要点

  • 日患者量≥40例时多剂量注射器几乎消除碘对比剂浪费,日患者量≥50例时年浪费为零。
  • 日患者量<20例时多剂量注射器每患者平均浪费高于单剂量注射器,Group 1高2.5倍、Group 2高71.4%。
  • 日患者量≥20例的各组中多剂量注射器每患者平均浪费低于单剂量注射器。

核心结论

  • 日患者量超过40例的高通量中心使用多剂量注射器可近乎消除碘对比剂浪费,而日患者量低于20例的中心使用多剂量注射器可能导致碘对比剂浪费增加。

研究设计与样本

  • 在作者所在急诊CT单元使用多剂量注射器进行为期一年的CT检查,记录每次注射的碘对比剂体积、时间和日期,按500 mL容器8小时使用窗计算年碘对比剂用量,并假设改用单剂量瓶加单剂量注射器(无8小时使用窗)计算同一患者队列的浪费。

诊断标准与关键数值

  • 按每日注射患者数分为6组:Group 1(<10例/日)、Group 2(10-19例/日)、Group 3(20-29例/日)、Group 4(30-39例/日)、Group 5(40-49例/日)、Group 6(≥50例/日);共12,290次扫描,多剂量注射器较单次使用注射器减少年碘对比剂浪费86.1%;日患者量≥50例时年浪费为零,40-49例/日时为253 mL;患者量与碘对比剂浪费呈显著负相关(r=-0.365,p<0.0001);每患者平均浪费Group 1多剂量较单剂量高2.5倍、Group 2高71.4%;Group 3减少53.9%、Group 4减少88.9%、Group 6减少100%。

临床应用与阅片要点

  • 选择注射器类型时需结合中心日患者量,日患者量≥40例的中心使用多剂量注射器可近乎消除碘对比剂浪费,日患者量<20例的中心使用多剂量注射器可能增加浪费。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Multidose iodinated contrast media (ICM) injectors have shown promise in reducing ICM waste. This study aims to evaluate the impact of patient volume on ICM waste reduction in multidose injectors.

METHODS: CT studies performed over one-year period with a multidose injector at our emergency CT unit. We recorded the ICM volume, time, and date for each injection and calculated total annual ICM use, accounting for the 500 mL ICM containers' 8-hour window usage limit. We then calculated the ICM waste for the same patient cohort assuming single-dose vials used with single-dose injectors were used instead, without the 8-hour window for usage. To assess the impact of patient volume, we evaluated six subgroups based on daily injected patient counts: Group 1 (<10 patients/day), Group 2 (10-19 patients/day), Group 3 (20-29 patients/day), Group 4 (30-39 patients/day), Group 5 (40-49 patients/day), Group 6 (≥50 patients/day). Annual and mean per patient ICM waste was calculated for both injector types and compared among all subgroups.

RESULTS: In total, across 12,290 scans, multidose injectors reduced annual ICM waste by 86.1% compared to single-use injectors. Annual ICM waste was zero on days with 50 or more patients and was minimal (253 mL) for days with 40-49 patients. A significant negative correlation between patient volume and ICM waste was observed (r=-0.365, p<0.0001). Mean ICM waste per patient was 2.5 times higher in Group 1 and 71.4% higher in Group 2 with multidose injector compared to single-dose injector. Conversely, in groups with at least 20 patients per day, mean ICM waste per patient was lower with multidose injectors compared to single-dose injectors. Mean ICM waste per patient was reduced by 53.9% in Group 3, 88.9% in Group 4 and 100% in Group 6.

CONCLUSION: High patient throughput centers with over 40 patients per day can nearly eliminate ICM waste with multidose injectors. However, using multidose injectors in centers with lower patient volumes (<20 patients per day) may lead to increased ICM waste compared to single-dose injectors, underscoring the importance of aligning injector choice with patient volume to optimize resource utilization and minimize waste.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Rafiei Alavi N, Limfueco J, Yamamoto R, et al. Impact of Patient Volume on Iodinated Contrast Material Waste with Multidose Contrast Injectors. Acad Radiol. 2024. PMID: 39732614. doi:10.1016/j.acra.2024.12.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。