在爱尔兰建立透视与透视引导介入的国家诊断参考水平并与欧洲及国际国家诊断参考水平比较
该研究通过在线调查爱尔兰全部提供透视与透视引导介入服务的医疗放射设施,以各设施中位剂量分布的75百分位建立国家Pka诊断参考水平,共覆盖52项临床适应证、解剖区域和操作,并建立EVAR与透视下腰椎穿刺的设备特异性成人DRL及两项儿科DRL;与其他国家DRL比较提示爱尔兰DRL通常较低。
要点
- 共建立52项透视与透视引导介入临床适应证、解剖区域和操作的国家Pka诊断参考水平。
- EVAR和透视下腰椎穿刺另建立平板探测器与影像增强器特异性成人DRL。
- 两项儿科适应证按不同体重类别建立DRL,爱尔兰DRL通常低于其他国家。
核心结论
- 基于普查数据建立了覆盖成人及儿科透视与透视引导介入的国家DRL,与其他国家已建立DRL比较时爱尔兰数值大多更低。
研究设计与样本
- 国家DRL建立研究,向全国所有提供透视与透视引导介入服务的医疗放射设施发放在线调查,以各设施中位剂量分布的75百分位设定国家Pka DRL,并设50百分位为国家中位剂量。
诊断标准与关键数值
- 国家Pka DRL设为各设施中位值分布的75百分位,国家中位剂量设为同一患者与条件下各设施中位剂量的50百分位。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The purpose of this work was to establish national Irish diagnostic reference levels (DRLs) for a clinically representative and comprehensive list of clinical indications, anatomical regions, and common procedures for fluoroscopy and fluoroscopically guided interventions and compare these, where possible, to other DRLs established at a national level.
METHOD: A list of clinical indications, anatomical regions and common procedures was established. A national database of service providers was used to identify all medical radiological facilities providing fluoroscopy and fluoroscopically guided intervention services. These facilities were issued with an online survey. National Pka DRLs were set as the 75th percentile of the distribution of median values obtained. A national median dose was also established which is the 50th percentile of the median doses provided by facilities for the same patients and conditions as the national DRL value. The broad categorisation of equipment type was also considered. Where statistically significant differences were found between different detector types, detector specific national DRLs were established (flat panel detector and image intensifier specific DRLs).
RESULTS: National Pka DRLs were established for 52 fluoroscopy and fluoroscopically guided intervention clinical indications, anatomical regions, and procedures. In addition, equipment specific (flat panel detector and image intensifier based systems) adult DRLs were established for the EVAR and lumbar puncture under fluoroscopy procedures. Paediatric DRLs were established for two fluoroscopy and fluoroscopically guided intervention clinical indications, anatomical regions, and procedures across various weight categories. Comparisons with other nationally set DRLs and other relevant literature suggest that Irish DRLs are typically lower than those established elsewhere.
CONCLUSIONS: This work provided a unique opportunity to establish national DRLs based on census data for a wide range of clinical indications, anatomical regions, and procedures across adult and paediatric fluoroscopy and fluoroscopically guided interventions. Where comparisons with other nationally established work was possible Irish values are largely below other DRLs.
引用
- O'Hora L, O'Brien K, Tuffy J, et al. Establishing national diagnostic reference levels in fluoroscopy and fluoroscopically guided interventions in Ireland and comparing these with national diagnostic reference levels in Europe and internationally. Eur J Radiol. 2024. PMID: 39724796. doi:10.1016/j.ejrad.2024.111890
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。