超声造影可能有效测量颈动脉体瘤中颈内动脉远端游离段长度
本先导研究纳入37例患者共38个确诊颈动脉体瘤,术前用灰阶超声、彩色多普勒超声和超声造影测量颈内动脉远端游离段长度,并与CTA比较。超声造影测量值与CTA无显著差异(P=0.595),且与估计出血量和手术时长呈显著负相关;作者认为超声造影可作为CTA的新型替代方法,但需更大样本和更长随访进一步研究。
要点
- 超声造影测量颈内动脉远端游离段长度与CTA无显著差异(P=0.595)。
- 彩色多普勒超声测量准确性显著低于灰阶超声、超声造影和CTA。
- 超声造影测量的游离段长度与估计出血量和手术时长呈显著负相关。
核心结论
- 超声造影可用于测量颈动脉体瘤患者的颈内动脉远端游离段长度,是CTA的新型替代方法,可避免使用放射性物质和碘对比剂。
研究设计与样本
- 先导研究,纳入37例患者共38个确诊颈动脉体瘤,术前均行灰阶超声、彩色多普勒超声和超声造影测量颈内动脉远端游离段长度,并与CTA结果比较。
诊断标准与关键数值
- 超声造影测量颈内动脉远端游离段长度与CTA比较无显著差异(P=0.595);骨面显示良好时灰阶超声与超声造影和CTA比较无显著差异(P=0.735和P=0.463);彩色多普勒超声测量准确性显著低于灰阶超声(P=0.033)、超声造影(P=0.001)和CTA(P<0.001)。
临床应用与阅片要点
- 作者认为超声造影可用于测量颈内动脉远端游离段长度,是CTA的新型替代方法,可避免使用放射性物质和碘对比剂。
局限性
- 本文为先导研究。
- 作者指出需要更大样本量和更长随访期的进一步研究来确定颈内动脉远端游离段长度对手术并发症的预测价值。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: This pilot study aimed to determine whether contrast-enhanced ultrasound (CEUS) is effective for measuring the free distal segment length of the internal carotid artery (FDS-ICA) in carotid body tumours (CBTs).
MATERIALS AND METHODS: Thirty-seven patients with 38 confirmed CBTs were enrolled. Before surgery, all patients underwent grey scale ultrasound (US), colour Doppler US (CDU), and CEUS. The FDS-ICA was measured using these three modes. Subsequently, the results were compared with those acquired using computed tomography angiography (CTA). Operative conditions, complications, and the correlation between US parameters and operative outcomes were assessed.
RESULTS: CEUS accurately measured FDS-ICA values, with no significant difference compared with CTA (P=0.595). Grey scale US measurements had a similar accuracy compared to CEUS and CTA when the bone surface was well visualised (P=0.735 and 0.463, respectively). However, CDU measurements were significantly less accurate than grey scale US, CEUS, and CTA measurements (P=0.033, P=0.001, and P<0.001, respectively). FDS-ICA measured using CEUS exhibited a significant negative correlation with both estimated blood loss and surgical duration; however, no association was observed between FDS-ICA and carotid artery or cranial nerve injuries.
CONCLUSION: CEUS can be used to measure the FDS-ICA and is a novel alternative to CTA, obviating the need for radioactive and iodine contrast agents. Further investigations with larger sample sizes and longer follow-up periods are warranted to establish the predictive value of FDS-ICA for surgical complications.
引用
- Liu S, Wang Y, Tan S, et al. Contrast-enhanced ultrasound may be effective for the measurement of the free distal segment length of the internal carotid artery in carotid body tumours. Clin Radiol. 2024. PMID: 39719734. doi:10.1016/j.crad.2024.106762
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。