应用超短回波时间绝热T1ρ磁共振成像无创评估银屑病关节炎患者跟腱及其附着点
横断面研究纳入44例银屑病关节炎患者与37名无症状志愿者,用3T磁共振超短回波时间绝热T1ρ序列测量跟腱及附着点。患者附着点(11.4±2.6 ms vs. 10.4±2.4 ms)和牵拉区肌腱(9.8±2.8 ms vs. 7.7±1.7 ms)T1ρ显著高于志愿者;有活动性跟腱疼痛者附着点T1ρ显著低于其他患者(10.7±2.6 ms vs. 11.7±2.5 ms),接受生物制剂治疗者肌腱T1ρ显著低于其他患者(9.5±2.5 ms vs. 10.3±3.3 ms)。
要点
- 银屑病关节炎患者跟腱附着点与牵拉区肌腱UTE-Adiab-T1ρ均高于无症状志愿者。
- 有活动性跟腱疼痛的患者附着点T1ρ低于其他患者,生物制剂治疗者肌腱T1ρ较低。
- VAS评分与附着点T1ρ呈显著但弱的负相关(R=-0.2)。
核心结论
- UTE-Adiab-T1ρ序列可用于评估跟腱及其附着点,并可能反映银屑病关节炎的累及或治疗反应。
研究设计与样本
- 横断面研究,纳入44例银屑病关节炎患者(59±15岁,38%女性)和37名无症状志愿者(32±10岁,51%女性),在3T临床扫描仪上使用3英寸表面线圈行矢状面3D UTE-Adiab-T1ρ脂肪抑制序列扫描。
关键影像表现/征象
- 银屑病关节炎组附着点UTE-Adiab-T1ρ为11.4±2.6 ms,无症状志愿者组为10.4±2.4 ms。
- 银屑病关节炎组牵拉区肌腱UTE-Adiab-T1ρ为9.8±2.8 ms,无症状志愿者组为7.7±1.7 ms。
- 有活动性跟腱疼痛的银屑病关节炎患者附着点T1ρ为10.7±2.6 ms,其他患者为11.7±2.5 ms。
- 接受生物制剂治疗的银屑病关节炎患者肌腱T1ρ为9.5±2.5 ms,其他患者为10.3±3.3 ms。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: This cross-sectional study investigates the utility of the quantitative ultrashort echo time (UTE) adiabatic T1ρ (UTE-Adiab-T1ρ) magnetic resonance imaging (MRI) in detecting potential differences in Achilles tendons and entheses of patients with psoriatic arthritis disease (PsA) compared with asymptomatic volunteers.
MATERIAL AND METHOD: The Achilles tendons of forty-four PsA patients (59 ± 15 years old, 38 % female) and thirty-seven asymptomatic volunteers (32 ± 10 years old, 51 % female) were scanned on a 3 T clinical scanner in the sagittal plane using a 3-inch surface coil. The 3D UTE-Adiab-T1ρ sequences with fat saturation (FS) were used to measure UTE-Adiab-T1ρ. Tenderness of the tendons, the SF-12 health survey, and visual analog scale (VAS) were recorded for the patients. The Kruskal Wallis test was used to examine the differences in UTE-Adiab-T1ρ values between asymptomatic volunteers and patients, as well as subgroups of patients with pain in the Achilles tendon region and those treated with Biologics. Spearman's correlation coefficients were calculated between UTE-Adiab-T1ρ and patient evaluations. P values < 0.05 were considered significant.
RESULTS: UTE-Adiab-T1ρ was significantly higher for the PsA group compared with the asymptomatic group in the enthesis (11.4 ± 2.6 ms vs. 10.4 ± 2.4 ms) and tensile tendon regions (9.8 ± 2.8 ms vs. 7.7 ± 1.7 ms). PsA patients with active Achilles pain showed significantly lower T1ρ in the entheses compared with other patients (10.7 ± 2.6 ms vs. 11.7 ± 2.5 ms). PsA patients treated with Biologics showed significantly lower T1ρ values in the tendon compared with other patients (9.5 ± 2.5 ms vs. 10.3 ± 3.3 ms). The VAS score of patients showed a significant negative but weak correlation (R = -0.2) with UTE-Adiab-T1ρ of the enthesis. Correlations with SF-12 scores were not significant.
CONCLUSION: This study highlighted the UTE-Adiab-T1ρ sequence capability in evaluating tendons and entheses and their potential involvement in PsA disease or response to therapies.
引用
- Moazamian D, Mohammadi HS, Athertya J, et al. Non-invasive evaluation of Achilles tendon and its enthesis using ultrashort echo time adiabatic T1ρ (UTE-Adiab-T1ρ) magnetic resonance imaging (MRI) in psoriatic arthritis. Eur J Radiol. 2024. PMID: 39667119. doi:10.1016/j.ejrad.2024.111841
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。