手指关节对比增强伪CT:提高检测炎性骨侵蚀的诊断信心
前瞻性纳入47例疑似或确诊类风湿关节炎患者,行手指对比增强MRI(CE-MRI),并基于非增强MRI和增强MRI数据分别生成伪CT(pCT)和增强伪CT(CE-pCT)。由两名肌骨放射科医生评估掌指关节和近端指间关节的骨侵蚀与骨内腱鞘囊肿,以独立第三读者基于CE-MRI的判定为参考标准。结果显示,CE-MRI联合CE-pCT对骨侵蚀和骨内腱鞘囊肿的诊断信心最高,CE-pCT优于pCT。
要点
- CE-MRI联合CE-pCT对骨侵蚀和骨内腱鞘囊肿的诊断信心最高(中位评分4)。
- CE-MRI联合pCT对骨侵蚀的诊断信心高于单独CE-MRI。
- CE-pCT在提高诊断信心方面优于pCT。
核心结论
- 伪CT联合CE-MRI可提高手指关节炎性骨侵蚀检测的诊断信心,且CE-pCT优于pCT。
研究设计与样本
- 前瞻性研究,纳入47例疑似或确诊类风湿关节炎患者,行手指CE-MRI,并基于非增强MRI和增强MRI数据分别生成pCT和CE-pCT(采用高分辨率梯度回波3D快速小角度激发序列FLASH);由两名肌骨放射科医生评估掌指关节和近端指间关节的骨侵蚀与骨内腱鞘囊肿,以独立第三读者基于CE-MRI的判定为参考标准。
诊断标准与关键数值
- 参考标准在CE-MRI上共发现44处骨侵蚀和37处骨内腱鞘囊肿。
- 单独CE-MRI对骨侵蚀(两名读者)和骨内腱鞘囊肿(读者2)的诊断信心为中等。
- CE-MRI联合pCT对骨侵蚀的诊断信心中位评分:读者1为3(Q1-Q3:2.5-3),读者2为3(3-3),均p<.001;对骨内腱鞘囊肿读者2为3(3-3),p<.001。
- CE-MRI联合CE-pCT对骨侵蚀的诊断信心中位评分:读者1为4(3-4),读者2为4(4-4),均p<.001;对骨内腱鞘囊肿两名读者均为4(4-4),p<.001。
临床应用与阅片要点
- 在CE-MRI基础上附加CE-pCT可提高对指关节炎性骨侵蚀和骨内腱鞘囊肿的检出信心。
- CE-pCT在提高诊断信心方面优于pCT。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the interest of additional pseudo-CT images to standard clinical contrast-enhanced MR images (CE-MRI) in the detection of inflammatory erosions and to differentiate them from intraosseous ganglia at the finger joints.
METHOD: 47 prospectively included patients with suspected or diagnosed rheumatoid arthritis received a CE-MRI of the fingers. Additionally, pseudo-CT images were derived from non-contrast MRI (pCT) and from contrast-enhanced MRI data (CE-pCT) using a high-resolution gradient-echo 3D fast low-angle shot sequence (FLASH), respectively. CE-MRI, pCT, and CE-pCT images were evaluated for erosions and intraosseous ganglia at the metacarpophalangeal and proximal interphalangeal joints by two musculoskeletal radiologists. Findings were defined on CE-MRI by an experienced independent 3rd reader which served as reference standard. Diagnostic confidence (1 = worst, 4 = best) was rated for 3 different image sets (1 = CE-MRI, 2 = CE-MRI + pCT, 3 = CE-MRI + CE-pCT) and compared.
RESULTS: Reference standard revealed 44 erosions and 37 intraosseous ganglia on CE-MRI. Diagnostic confidence for CE-MRI was moderate for erosions (both readers) and intraosseous ganglia (reader 2). For the combination of CE-MRI and pCT, high confidence levels were observed for erosions for both readers (median 3 (Q1-Q3: 2.5-3) and 3 (3-3); p<.001 and p<.001) and for intraosseous ganglia for reader 2 (3 (3-3); p<.001). CE-MRI combined with CE-pCT showed very high confidence levels for both readers for erosions (4 (3-4) and 4 (4-4); p<.001 and p<.001) and for intraosseous ganglia (4 (4-4) and 4 (4-4); p<.001 and p<.001).
CONCLUSIONS: Pseudo-CT combined with CE-MRI increases the confidence in detection of inflammatory erosions at the finger joints, with CE-pCT being superior to pCT.
引用
- Stern C, Feuerriegel GC, Germann C, et al. Contrast-enhanced pseudo-CT of finger joints: Improved diagnostic confidence for detection of inflammatory erosions. Eur J Radiol. 2024. PMID: 39662426. doi:10.1016/j.ejrad.2024.111856
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。