文献速递乳腺介入US乳腺X线

针头尺寸对乳腺病变真空辅助切除术结局的影响:一项随机对照试验

Effect of needle size on outcomes of vacuum-assisted excision of breast lesions. A randomized controlled trial.
PubMed 文献 · Eur J Radiol · 2024-12-25

这项前瞻性单盲随机对照试验纳入194例超声可见的<30 mm乳腺病变(B2/B3或BI-RADS 3/4a微钙化<15 mm),比较7G与10G针头行真空辅助切除术。结果显示两种针头在手术时间(7.7 min vs 8.5 min,P=0.126)和6个月随访病变完全切除率(90% vs 81.5%,P=0.109)上无显著差异,仅较大病变尺寸与更长手术时间和更高不完全切除风险相关。

要点

  • 7G与10G针头在手术时间和6个月完全切除率上无显著差异。
  • 较大病变尺寸与更长手术时间及更高不完全切除风险相关。
  • 微钙化立体定向切除后残留病变比例为30%(6/20),高于超声引导下导管内病变的2.5%(1/42)。

核心结论

  • 使用10G与7G针头相比,手术时间或切除完整性无差异;仅较大病变尺寸与更长手术时间和更高不完全切除风险相关。

研究设计与样本

  • 前瞻性、单盲、随机对照试验,2019年11月至2022年8月入组,筛查208例,因撤回知情同意后试验人群为194例,随访在术后6和24个月进行。

关键影像表现/征象

  • 6个月随访时,7G针头组90%未见残留病变,10G针头组81.5%未见残留病变(P=0.109)。
  • 微钙化经乳腺X线立体定向引导切除的患者中30%(6/20)有残留病变,超声引导下导管内病变切除的患者中2.5%(1/42)有残留病变。

局限性

  • 85%的患者参加了6个月随访,65%参加了24个月随访。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Utilizing a larger needle-size instead of a smaller one in vacuum-assisted excision of breast lesions might enhance the effectiveness of the method. We conducted a clinical trial to investigate the effects of needle size 7G compared to 10G regarding excision completeness and procedural efficiency.

MATERIALS AND METHODS: In this prospective, single-blinded, randomized clinical trial, the patients were enrolled between November 2019 and August 2022. Follow-up examinations were performed at 6 and 24 months after the procedure. In total, 208 patients were screened and enrolled, and following withdrawal of consent, the trial population comprised 194 patients. All patients with ultrasound-visible lesions of <30 mm in size and biopsy confirmation corresponding to a B2 or B3 lesion were included in the study. Additionally, patients with BI-RADS 3 and 4a microcalcifications measuring <15 mm were also eligible. Eighty-five percent of the patients attended the 6-month follow-up, and 65 % attended the 24-month follow-up.

RESULTS: There were no significant difference between the two randomization arms in terms of age, and lesion size. The mean procedure time was 7.7 min and 8.5 min for 7G and 10G needle size, respectively (=0.126). Of the 164 patients who attended the 6-month follow-up, no remaining lesions were found in 90 % and 81.5 % (p = 0.109) patients for 7G and 10G needle size respectively. Thirty percent (6/20) of the patients with microcalcifications excised stereotactically, guided by mammography, had a residual lesion compared to 2.5 % (1/42) of the patients with intraductal lesions excised under ultrasound guidance.

CONCLUSIONS: Using a 10G compared to a 7G needle size resulted in no difference in procedure time or excision completeness. Among the analyzed parameters, only a larger lesion size was consistently associated with a longer procedure time and a higher risk of incomplete excision.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Zouzos A, Fredriksson I, Karakatsanis A, et al. Effect of needle size on outcomes of vacuum-assisted excision of breast lesions. A randomized controlled trial. Eur J Radiol. 2024. PMID: 39724795. doi:10.1016/j.ejrad.2024.111895

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。