Kaiser评分在MRI BI-RADS 3类病变中的诊断效能:减少不必要活检的有前景工具
本研究为回顾性单中心研究,纳入79例有危险因素且MRI诊断为BI-RADS 3类病变后接受活检的女性患者,由三名阅片者盲法应用Kaiser评分(KS≤4判为良性)并以组织病理为金标准评估诊断效能。结果显示三名阅片者AUC分别为0.99、0.99和0.90,敏感度0.92、1.00和0.75,特异度1.00、0.99和1.00;采用KS≤4判为良性可避免66至67例活检(占全部活检的84%至85%),Fleiss kappa为0.792。
要点
- KS≤4判为良性时,可避免66至67例活检(占全部活检的84%至85%)。
- 两名乳腺放射科医师敏感度分别为0.92和1.00,特异度分别为1.00和0.99。
- 住院医师敏感度为0.75,特异度为1.00,AUC为0.90。
核心结论
- 应用Kaiser评分可避免84%至85%的活检,该评分快速、易用、观察者间一致性强且特异度高。
研究设计与样本
- 回顾性单中心研究,纳入79例有危险因素且MRI诊断为BI-RADS 3类病变后接受活检的女性患者,由两名有经验的乳腺放射科医师和一名放射科住院医师盲法应用Kaiser评分,以组织病理学为金标准。
诊断标准与关键数值
- Kaiser评分≤4分判为良性;三名阅片者AUC分别为0.99、0.99和0.90;两名乳腺放射科医师敏感度分别为0.92(95%CI 0.62-0.99)和1.00(95%CI 0.95-1.00),特异度分别为1.00(95%CI 0.95-1.00)和0.99(95%CI 0.92-1.00);住院医师敏感度为0.75(95%CI 0.42-0.95),特异度为1.00(95%CI 0.95-1.00)。
临床应用与阅片要点
- 采用Kaiser评分≤4分判为良性时,可避免66至67例活检(占全部活检的84%至85%);三名阅片者间Fleiss kappa为0.792(95%CI 0.68-0.91)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the possibility of reducing unnecessary biopsies in patients with BI-RADS 3 lesions by implementing Kaiser score (KS).
METHOD: In this retrospective, single-center study, we included 79 female patients with BI-RADS 3 lesions and risk factors who underwent biopsy following magnetic resonance imaging. Three readers (two experienced breast radiologists and a radiology resident) blinded evaluated the lesions using KS. Lesions with a KS ≤ 4 were considered benign. Results were compared with the histopathological findings (gold standard) assessing sensitivity and specificity along with 95 % confidence intervals (CI) for each reader. Inter-reader agreement was assessed using Fleiss' kappa with 95 % CIs. Moreover, Cohen's kappa was used to assess concordance between two readers at time.
RESULTS: 79 female patients (mean age, 50.9 ± 12.2 (standard deviation)) were evaluated. The area under the receiver operating characteristic curve for the three readers was excellent: 0.99, 0.99, and 0.90), respectively. The sensitivity of the two breast radiologists and the resident was 0.92 (95 % CI: 0.62 - 0.99), 1.00 (95 % CI: 0.95 - 1.00) and 0.75 (95 % CI: 0.42 - 0.95), respectively, while the specificity was 1.00 (95 % CI: 0.95---1.00), 0.99 (95 % CI: 0.92 - 1.00), and 1.00 (95 % CI: 0.95 - 1.00) respectively. By using a KS ≤ 4 value to indicate benignity, 66 to 67 biopsies (84 to 85 % of all the biopsies) would have been avoided. Inter-reader concordance via Fleiss' kappa was 0.792 (95 % CI: 0.68 - 0.91).
CONCLUSIONS: The implementation of KS could have spared 84-85% of biopsies, proving to be a quick, user-friendly tool with strong inter-observer agreement and high specificity.