文献速递乳腺MR

同时多层扩散加权成像鉴别乳腺病变的诊断效能:系统评价与Meta分析

Diagnostic performance of simultaneous multislice diffusion-weighted imaging in differentiating breast lesions: a systematic review and meta-analysis.
PubMed 文献 · Br J Radiol · 2025-01-01

该系统评价与Meta分析纳入6项比较研究、626例患者共649个乳腺病变(良性222个、恶性427个),以组织病理学为参考标准,比较同时多层扩散加权成像(SMS-DWI)与常规单次激发及读出分段回波平面成像无SMS技术的诊断效能。SMS-DWI汇总敏感度0.89、特异度0.94、AUC 0.96,常规DWI分别为0.90、0.87、0.94,两者诊断效能无显著差异(P=.337)。作者认为SMS-DWI可能成为乳腺成像中常规DWI的潜在替代方法。

要点

  • SMS-DWI鉴别乳腺良恶性病变汇总敏感度0.89、特异度0.94、AUC 0.96。
  • 常规DWI汇总敏感度0.90、特异度0.87、AUC 0.94,两者诊断效能无显著差异(P=.337)。
  • 作者认为SMS-DWI可能成为乳腺成像中常规DWI的潜在替代方法。

核心结论

  • SMS-DWI在鉴别乳腺良恶性病变方面具有高诊断效能,与常规DWI无显著差异(P=.337);SMS-DWI可能成为乳腺成像中常规DWI的潜在替代方法。

研究设计与样本

  • 系统评价与Meta分析,检索PubMed、Embase和Web of Science,纳入6项比较研究,共626例患者、649个乳腺病变(良性222个、恶性427个),以组织病理学分析为恶性乳腺病变的参考标准,采用QUADAS-2量表评价方法学质量,使用双变量随机效应模型计算并比较汇总敏感度、汇总特异度和汇总受试者工作特征曲线下面积(AUC)。

诊断标准与关键数值

  • SMS-DWI汇总敏感度0.89(95%CI:0.78-0.95)、汇总特异度0.94(95%CI:0.81-0.98)、AUC 0.96(95%CI:0.94-0.98);常规DWI汇总敏感度0.90(95CI:0.84-0.94)、汇总特异度0.87(95%CI:0.80-0.92)、AUC 0.94(95%CI:0.92-0.96);两者诊断效能无显著差异(P=.337)。

临床应用与阅片要点

  • 作者认为SMS-DWI可能成为乳腺成像中常规DWI的潜在替代方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the diagnostic performance of simultaneous multislice diffusion-weighted imaging (SMS-DWI) in differentiating malignant and benign breast lesions, and compare it with conventional single shot and readout segmented echo planar imaging without the SMS technique.

METHODS: The literature search was performed in PubMed, Embase, and Web of Science to identify comparative studies reporting the diagnostic performance of SMS-DWI and conventional DWI in patients with breast lesions. Histopathological analysis was used as a reference standard for malignant breast lesions. The methodological quality was evaluated using QUADAS-2 scale. The summary sensitivity, summary specificity, and area under the curve (AUC) of the summarized receiver operating characteristic curve were calculated and compared between SMS-DWI and conventional DWI using a bivariate random-effects model. Heterogeneity was explored with meta-regression and subgroup analyses.

RESULTS: Six studies with 626 patients and 649 breast lesions (benign: 222, malignant: 427) were included. The summary sensitivity, summary specificity, and AUC for SMS-DWI were 0.89 (95% CI: 0.78-0.95), 0.94 (95% CI: 0.81-0.98), and 0.96 (95% CI: 0.94-0.98), respectively, and those for conventional DWI were 0.90 (0.95 CI: 0.84-0.94), 0.87 (95% CI: 0.80-0.92), and 0.94 (95% CI: 0.92-0.96), respectively. The diagnostic performance was not significantly different between SMS-DWI and conventional DWI (P = .337).

CONCLUSIONS: SMS-DWI has high diagnostic performance in differentiating breast lesions, which is not significantly different from the conventional DWI.

ADVANCES IN KNOWLEDGE: There is no significant difference between SMS-DWI and conventional DWI in differentiating breast lesions, suggesting SMS-DWI may be a potential alternative to conventional DWI in breast imaging.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Tan Y, Ye Z, Lv X, et al. Diagnostic performance of simultaneous multislice diffusion-weighted imaging in differentiating breast lesions: a systematic review and meta-analysis. Br J Radiol. 2025. PMID: 39658329. doi:10.1093/bjr/tqae240

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。