该研究纳入2018年1月至2022年12月间63例乳头状乳腺病变患者共86个病灶,在对比增强乳腺X线摄影注射对比剂后2-3分钟(T1早期)和4-5分钟(T2后期)评估BI-RADS病灶特征与动力学强化模式;联合动力学强化与形态学分类的CEM AUC为0.856,高于单独CEM的0.800,特异度71.1% vs 60.0%、准确率79.4% vs 71.4%,敏感度与阴性预测值均为100%。作者认为对BI-RADS 3-5乳头状乳腺病变,在形态学模式中加入CEM动力学强化可提高诊断信心。

要点

  • 对BI-RADS 3-5乳头状乳腺病变,联合CEM动力学强化与形态学分类的AUC为0.856,高于单独CEM的0.800。
  • 联合动力学强化后特异度71.1% vs 单独CEM 60.0%,准确率79.4% vs 71.4%,敏感度与阴性预测值均为100%。
  • CEM于注射对比剂后2-3分钟(T1早期)和4-5分钟(T2后期)两个时间点评估动力学强化模式。

核心结论

  • 对BI-RADS 3-5乳头状乳腺病变,在CEM形态学模式中加入动力学强化分析可提高诊断信心;联合动力学强化的CEM AUC为0.856,高于单独CEM的0.800。

研究设计与样本

  • 研究纳入2018年1月至2022年12月间63例乳头状乳腺病变患者,共识别86个病灶;CEM于注射对比剂后2-3分钟(T1早期)和4-5分钟(T2后期)两个时间点进行,记录BI-RADS病灶特征并评估两期动力学强化模式,随后测量诊断效能。

诊断标准与关键数值

  • 86个病灶中恶性18个、无不典型增生的导管内乳头状瘤3个、良性乳头状病变42个;联合动力学强化与形态学分类的CEM AUC为0.856,单独CEM为0.800;联合动力学强化的特异度71.1% vs 单独CEM形态学分类60.0%,准确率79.4% vs 71.4%,敏感度与阴性预测值均为100%。

临床应用与阅片要点

  • 作者认为对BI-RADS 3-5乳头状乳腺病变,在CEM形态学模式中加入动力学强化分析可提高诊断信心。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the capability of morphological and enhancement pattern analysis in contrast-enhanced mammography (CEM) to differentiate between benign and malignant papillary breast lesions.

METHODS: This study involved 63 patients diagnosed with papillary breast lesions between January 2018 and December 2022. CEM was performed at two time intervals: between 2-3 min (T1, early phase) and 4-5 min (T2, later phase) after the injection of the contrast agent. For each patient, Breast Imaging Reporting and Data System (BI-RADS) lesion features were recorded. Kinetic enhancement patterns were evaluated for both phases based on these changes, followed by the measurement of diagnostic performance.

RESULTS: Among the 63 female patients, a total of 86 lesions were identified, including 18 malignant ones, three intraductal papillomas without atypical proliferation, and 42 benign papillary lesions. The areas under receiver operating characteristic curves for CEM with kinetic enhancement and for CEM alone were 0.856 and 0.800, respectively. Assessing the diagnostic value, specificity, and accuracy of morphological categorization combined with kinetic enhancement showed higher values compared to those of the CEM morphological categorization alone (71.1% vs 60.0% and 79.4% vs 71.4%, respectively). However, the sensitivity and negative predictive value of the CEM with kinetic enhancement were similar to those of CEM alone (100% for all).

CONCLUSION: For BI-RADS 3-5 papillary breast lesions, incorporating CEM kinetic enhancement to morphological patterns improved the confidence level in diagnosis.

ADVANCES IN KNOWLEDGE: This article provides valuable references for distinguishing benign and malignant breast papillary lesions.