文献速递乳腺乳腺X线MR

增强乳腺X线摄影与MRI的背景实质强化:两者总是一致吗?

Background parenchymal enhancement in CEM and MRI: Is there always a high agreement?
PubMed 文献 · Eur J Radiol · 2024-12-25

回顾性纳入2018至2022年同时接受增强乳腺X线摄影(CEM)和MRI的343例女性,由两名乳腺放射科医师按BI-RADS评估背景实质强化(BPE)。CEM与MRI早期强化时相BPE一致性为一般(κ=0.342/0.383),延迟时相为中等至一般;读者间可重复性高(CEM κ=0.678,MRI κ=0.690/0.692)。CEM中BPE与乳腺密度正相关,与压迫力负相关。

要点

  • CEM与MRI早期时相BPE一致性一般(κ=0.342/0.383),延迟时相为中等至一般(κ=0.432/0.368)。
  • 两模态读者间可重复性均高:CEM κ=0.678,MRI早期κ=0.690、晚期κ=0.692。
  • CEM中BPE与乳腺密度正相关(ρ=0.399/0.441),与压迫力负相关(ρ=-0.100)。

核心结论

  • MRI与CEM的BPE评估一致性为一般至中等,读者间可重复性高。
  • 压迫力和乳腺X线密度似乎影响CEM的BPE水平。
  • 绝经后患者BPE水平较低(p<0.001)。

研究设计与样本

  • 回顾性、经机构审查委员会批准的研究,2018至2022年连续纳入343例因筛查召回或乳腺X线/超声结果不确定而同时接受CEM和MRI的女性。
  • 影像方案遵循国际建议,两名乳腺放射科医师按BI-RADS评估密度和BPE,评估早期强化时相(EP)及MRI延迟强化时相(LP)。
  • 采集绝经状态、乳房厚度和压迫力数据,采用单因素和多因素分析。

关键影像表现/征象

  • 绝经后患者BPE水平较低(p<0.001)。
  • CEM中BPE与乳腺密度显著相关(R1 ρ=0.399,R2 ρ=0.441;p<0.001)。
  • CEM中BPE与压迫力呈负相关(ρ=-0.100,p=0.001)。

诊断标准与关键数值

  • 采用BI-RADS评估乳腺密度和BPE。
  • CEM与MRI早期时相BPE一致性:R1 κ=0.342,R2 κ=0.383(一般)。
  • CEM与MRI延迟时相BPE一致性:R1 κ=0.432(中等),R2 κ=0.368(一般)。
  • 读者间一致性:CEM κ=0.678,MRI-EP κ=0.690,MRI-EP κ=0.692(原文两处写作MRI-EP)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

INTRODUCTION: Background parenchymal enhancement (BPE) refers to the physiological enhancement of breast fibroglandular tissue. This study aimed to determine the agreement of BPE evaluation between contrast enhanced mammography (CEM) and magnetic resonance imaging (MRI) and investigate potential confounders.

MATERIALS AND METHODS: This retrospective, IRB-approved study included women recalled from screening or with inconclusive findings on mammography and/or ultrasound, who underwent both CEM and MRI between 2018 and 2022. Imaging protocols followed international recommendations. Two breast radiology fellows assessed density and BPE on CEM and MRI using BI-RADS, evaluating the early post-contrast acquisition (EP). In addition, BPE on MRI was assessed in the late post-contrast acquisition (LP). Data on menopausal status, breast thickness, and compression force were retrieved. Univariate and multivariate analyses were used.

RESULTS: 343 patients were consecutively enrolled. Post-menopausal patients showed lower BPE levels (p < 0.001). Agreement on BPE levels between CEM and MRI in the EP was fair (R1 κ = 0.342, R2 κ = 0.383). In the LP agreement was moderate for R1 (κ = 0.432) and fair for R2 (κ 0.368). There was a significant correlation between BPE and density in CEM (R1 ρ 0.399, R2 ρ 0.441; p < 0.001). A negative correlation was found on CEM between BPE and compression force (ρ -0.100, p = 0.001). Inter-reader agreement was high with both modalities (CEM κ = 0.678, MRI-EP κ = 0.690, MRI-EP κ = 0.692).

CONCLUSIONS: The agreement of BPE assessment between MRI and CEM was fair to moderate and reproducibility among readers was high. Compression force and mammographic breast density seem to influence BPE levels in CEM.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Ferrara F, Santonocito A, Vogel W, et al. Background parenchymal enhancement in CEM and MRI: Is there always a high agreement? Eur J Radiol. 2024. PMID: 39736216. doi:10.1016/j.ejrad.2024.111903

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。