文献速递妇产影像技术与安全MR

半傅里叶单次激发快速自旋回波成像联合深度学习重建在妇科磁共振成像中的可行性及临床效用

Feasibility/clinical utility of half-Fourier single-shot turbo spin echo imaging combined with deep learning reconstruction in gynecologic magnetic resonance imaging.
PubMed 文献 · Abdom Radiol (NY) · 2024-12-18

回顾性纳入79例无解痉药妇科MRI患者行iHASTE、HASTE和BLADE,另匹配79例用解痉药行TSE者;iHASTE组织对比度显著优于HASTE和BLADE,伪影鲁棒性优于BLADE和TSE,但病灶边缘评分低于BLADE和TSE。作者认为iHASTE在无解痉药妇科MRI中是可行选择,也可考虑作为用解痉药MRI的补充序列。

要点

  • iHASTE组织对比度显著优于HASTE和BLADE。
  • iHASTE对伪影的鲁棒性优于BLADE和TSE。
  • iHASTE病灶边缘评分低于BLADE和TSE。

核心结论

  • iHASTE在无解痉药妇科MRI中是可行的临床选择,也可考虑作为用解痉药MRI的有用补充序列。

研究设计与样本

  • 回顾性研究,无解痉药组79例患者行iHASTE、HASTE和BLADE,有解痉药组79例病例对照匹配患者行TSE。

关键影像表现/征象

  • 定量评估显示iHASTE组织对比度显著优于HASTE和BLADE。
  • 定性评估显示iHASTE总体质量优于HASTE。
  • 三名放射科医师中两人判断iHASTE显著优于BLADE,两人判断TSE显著优于iHASTE。
  • iHASTE对伪影的鲁棒性优于BLADE和TSE。
  • iHASTE病灶边缘评分低于BLADE和TSE。

临床应用与阅片要点

  • iHASTE可作为无解痉药妇科MRI的可行临床选择。
  • iHASTE也可考虑作为使用解痉药MRI的有用补充序列。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: When antispasmodics are unavailable, the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER; called BLADE by Siemens Healthineers) or half Fourier single-shot turbo spin echo (HASTE) is clinically used in gynecologic MRI. However, their imaging qualities are limited compared to Turbo Spin Echo (TSE) with antispasmodics. Even with antispasmodics, TSE can be artifact-affected, necessitating a rapid backup sequence.

PURPOSE: This study aimed to investigate the utility of HASTE with deep learning reconstruction and variable flip angle evolution (iHASTE) compared to conventional sequences with and without antispasmodics.

MATERIALS AND METHODS: This retrospective study included MRI scans without antispasmodics for 79 patients who underwent iHASTE, HASTE, and BLADE and MRI scans with antispasmodics for 79 case-control matched patients who underwent TSE. Three radiologists qualitatively evaluated image quality, robustness to artifacts, tissue contrast, and uterine lesion margins. Tissue contrast was also quantitatively evaluated.

RESULTS: Quantitative evaluations revealed that iHASTE exhibited significantly superior tissue contrast to HASTE and BLADE. Qualitative evaluations indicated that iHASTE outperformed HASTE in overall quality. Two of three radiologists judged iHASTE to be significantly superior to BLADE, while two of three judged TSE to be significantly superior to iHASTE. iHASTE demonstrated greater robustness to artifacts than both BLADE and TSE. Lesion margins in iHASTE had lower scores than BLADE and TSE.

CONCLUSION: iHASTE is a viable clinical option in patients undergoing gynecologic MRI with anti-spasmodics. iHASTE may also be considered as a useful add-on sequence in patients undergoing MRI with antispasmodics.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Kirita M, Himoto Y, Kurata Y, et al. Feasibility/clinical utility of half-Fourier single-shot turbo spin echo imaging combined with deep learning reconstruction in gynecologic magnetic resonance imaging. Abdom Radiol (NY). 2024. PMID: 39692759. doi:10.1007/s00261-024-04739-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。