ZOOMit扩散峰度成像联合扩散加权成像评估子宫内膜癌微卫星不稳定性
回顾性分析81例子宫内膜癌患者术前盆腔MRI的ZOOMit DKI与DWI,比较微卫星稳定(MSS)与微卫星不稳定(MSI)组的ADC、MD、MK值及临床病理特征。MSI组ADC和MD值显著更低、MK值和Ki-67增殖水平显著更高;MD和MK为独立预测因子,二者联合AUROC为0.860(95%CI 0.765, 0.927),但与各单参数相比无显著差异。
要点
- MSI组ADC和MD值显著低于MSS组,MK值和Ki-67增殖水平显著高于MSS组。
- MD和MK是判断MSI的独立预测因子,二者联合AUROC为0.860(95%CI 0.765, 0.927)。
- 联合模型诊断效能与各单参数相比无显著差异。
核心结论
- ZOOMit DKI的微结构异质性评估可表征子宫内膜癌的MSI状态,DKI可能作为术前评估MSI肿瘤的潜在无创影像生物标志物提供附加价值,从而促进临床决策。
研究设计与样本
- 回顾性分析81例子宫内膜癌患者术前盆腔MRI(包括ZOOMit DKI和DWI),比较不同微卫星状态组的ADC、MK、MD值、MRI最大肿瘤径线及临床病理特征。
关键影像表现/征象
- MSI组ADC和MD值显著低于MSS组。
- MSI组MK值和Ki-67增殖水平显著高于MSS组。
- 定量参数测量的观察者间一致性极好(ICC 0.78-0.98)。
诊断标准与关键数值
- MD和MK为判断MSI的独立预测因子。
- MD与MK联合诊断MSI的AUROC为0.860(95%CI 0.765, 0.927),与各单参数相比无显著差异。
- 81例患者中MSS 59例(72.8%),MSI 22例(27.2%)。
临床应用与阅片要点
- 作者认为,在当前普遍开展MSI检测的范式下,DKI可能作为术前评估MSI肿瘤的潜在无创影像生物标志物提供附加价值。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Detecting microsatellite instability (MSI) plays a key role in the management of endometrial cancer (EC), as it is a critical predictive biomarker for Lynch syndrome or immunotherapy response. A pressing need exists for cost-efficient, broadly accessible tools to aid patient for universal testing. Herein, we investigate the value of ZOOMit diffusion kurtosis imaging (DKI) and diffusion weighted imaging (DWI) based on preoperative pelvic magnetic resonance imaging (MRI) images in assessing MSI in EC.
METHODS: Preoperative MRI examination including ZOOMit DKI and DWI of 81 EC patients were retrospectively analyzed. The apparent diffusion coefficient (ADC), mean kurtosis (MK), mean diffusivity (MD) and the largest tumor size based on MRI images, as well as patients' clinicopathological features were compared and analyzed according to different microsatellite statuses.
RESULTS: Of the 81 patients, 59 (72.8%) who were microsatellite stability (MSS) and 22 (27.2%) who were MSI. Interobserver agreement for the quantitative parameter measurements was excellent (ICC 0.78-0.98). The ADC and MD values were significantly lower, while Ki-67 proliferation level and MK values were significantly higher in the MSI group compared to those of the MSS group. The parameters of MD and MK were independent predictors for determining MSI, and their combination showed better diagnostic efficacy with an area under the receiver operating characteristic curve (AUROC) of 0.860 (95% confidence interval, 0.765, 0.927), although there was no significant difference compared to each individual parameter.
CONCLUSION: The microstructural heterogeneity assessment of ZOOMit DKI allowed for characterizing MSI status in EC. Within the current universal MSI testing paradigm, DKI may provide added value as a potential noninvasive imaging biomarker for preoperative assessment of MSI tumors, thereby facilitating clinical decision-making.
引用
- Wang F, Wang Y, Ran C, et al. ZOOMit diffusion kurtosis imaging combined with diffusion weighted imaging for the assessment of microsatellite instability in endometrial cancer. Abdom Radiol (NY). 2024. PMID: 39641783. doi:10.1007/s00261-024-04720-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。