基于超声的ADNEX模型鉴别良性、交界性与恶性上皮性卵巢肿瘤
单中心回顾性研究纳入813例上皮性卵巢肿瘤患者,以组织病理为金标准,评估IOTA-ADNEX模型鉴别良性、交界性与恶性肿瘤的能力。以10%为卵巢癌总体风险阈值时,敏感度99.1%、特异度73.2%;模型对良性 vs 恶性及交界性 vs II-IV期卵巢癌的AUC较高,但对交界性 vs I期卵巢癌的AUC仅为0.614。
要点
- ADNEX模型以10%为阈值识别卵巢癌总体风险时,敏感度99.1%、特异度73.2%。
- 鉴别良性 vs 恶性上皮性卵巢肿瘤的AUC为0.987(95%CI 0.981-0.993)。
- 鉴别交界性 vs I期卵巢癌的AUC仅0.614(95%CI 0.519-0.709)。
核心结论
- IOTA-ADNEX模型对三类上皮性卵巢肿瘤均表现出良好的诊断性能,未来可能有助于放射科医生评估附件肿块。
研究设计与样本
- 单中心回顾性研究,纳入813例经超声检查和盆腔手术的上皮性卵巢肿瘤患者,以组织病理诊断为金标准。
诊断标准与关键数值
- 以10%为阈值识别卵巢癌总体风险时,敏感度99.1%、特异度73.2%。
- 良性 vs 恶性上皮性卵巢肿瘤的AUC为0.987(95%CI 0.981-0.993)。
- 良性 vs 交界性上皮性卵巢肿瘤的AUC为0.820(95%CI 0.768-0.872)。
- 良性 vs I期卵巢癌的AUC为0.912(95%CI 0.876-0.948),良性 vs II-IV期卵巢癌的AUC为0.995(95%CI 0.992-0.998)。
- 交界性 vs I期卵巢癌的AUC为0.614(95%CI 0.519-0.709),交界性 vs II-IV期卵巢癌的AUC为0.903(95%CI 0.869-0.937)。
临床应用与阅片要点
- ADNEX模型可能有助于放射科医生评估附件肿块,但原文未给出具体阅片操作建议。
局限性
- 原文自述为单中心回顾性研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: The purpose of this study was to evaluate the ability of the International Ovarian Tumor Analysis-Assessment of Different NEoplasias in the adneXa (IOTA-ADNEX) model to distinguish among benign, borderline, and malignant epithelial ovarian tumours (BeEOTs, BEOTs, and MEOTs, respectively).
METHODS: The study included 813 patients with BeEOTs, BEOTs, and MEOTs who underwent ultrasound examinations and pelvic operations. Comparisons were made between the clinical information and ultrasonographic features of the three patient groups, and the histopathological diagnosis was the gold standard. The sensitivity, specificity, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve (AUC) of the ADNEX model were calculated.
RESULTS: This was a single-centre retrospective study. Of the 813 patients, 257 (31.6%) had BeEOTs, 114 (14.0%) had BEOTs, and 442 (54.4%) had MEOTs. For a cut-off value of 10% to identify the overall risk for ovarian cancer (OC), the sensitivity and specificity were 99.1% and 73.2%, respectively. According to the receiver operating characteristicscurves, the AUC was 0.987 (95% CI: 0.981-0.993) for BeEOTs compared with MEOTs, 0.820 (95% CI: 0.768-0.872) for BeEOTs compared with BEOTs, 0.912 (95% CI: 0.876-0.948) for BeEOTs compared with stage I OC, and 0.995 (95% CI: 0.992-0.998) for BeEOTs compared with stages II-IV OC. The AUC was 0.614 (95% CI: 0.519-0.709) for BEOTs compared with stage I OC, 0.903 (95% CI: 0.869-0.937) for BEOTs compared with stages II-IV OC, and 0.851 (95% CI: 0.800-0.902) for stage I OC compared with stages II-IV OC.
CONCLUSIONS: The IOTA-ADNEX model demonstrated good diagnostic performance for the three categories of EOTs and may have the potential to be popularised in assisting radiologists in the assessment of adnexal masses in the future.
引用
- Xie W, Zhang Q, Wang Y, et al. Ultrasound-based ADNEX model for differentiating between benign, borderline, and malignant epithelial ovarian tumours. Clin Radiol. 2024. PMID: 39721319. doi:10.1016/j.crad.2024.106761
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。