子宫腺肉瘤的磁共振成像特征:病例系列与系统综述
通过系统综述与病例系列分析总结子宫腺肉瘤的MRI特征,共纳入文献25例及本机构5例。中位年龄48.5岁,异常出血最常见(96.7%),多数为息肉样病变(90.0%)伴囊性变(96.5%)和出血(84.6%),T2WI信号高或中等,增强后均不均匀强化,平均ADC值1.05×10-3 mm2/s。
要点
- 子宫腺肉瘤多表现为宫体内膜来源的息肉样肿块,常突入宫颈管。
- 囊性变(96.5%)和出血(84.6%)常见,T2WI信号高或中等,增强后不均匀强化。
- 平均ADC值1.05×10-3 mm2/s,可能有助于与其他子宫恶性肿瘤鉴别。
核心结论
- 子宫腺肉瘤MRI多表现为宫体内膜来源的息肉样肿块,伴囊性变和出血,T2WI信号高或中等,增强后不均匀强化,平均ADC值1.05×10-3 mm2/s,这些特征可能有助于术前诊断及与其他子宫恶性肿瘤鉴别。
研究设计与样本
- 系统综述与病例系列分析,检索MEDLINE、Scopus和Embase数据库(2024年6月3日),纳入23篇文章的25例及作者机构的5例,由两名委员会认证的放射科医生评估人口学、临床和影像学数据。
关键影像表现/征象
- 病变平均最长径9.3 cm,93.1%位于宫体,96.6%主要累及子宫内膜,90.0%为息肉样病变,80.8%突入宫颈管,囊性变占96.5%,出血占84.6%,T2WI信号较子宫肌层高占51.7%、中等占48.3%,所有病变增强后均不均匀强化。
诊断标准与关键数值
- 平均ADC值为1.05×10-3 mm2/s;病理T1期占85.2%,肉瘤过度生长占55.2%,局部/远处复发占36.4%。
临床应用与阅片要点
- 阅片时注意宫体内膜来源的息肉样肿块,常突入宫颈管,伴囊性变和出血,T2WI信号高或中等,增强后不均匀强化,平均ADC值1.05×10-3 mm2/s,这些特征可能有助于术前诊断及鉴别其他子宫恶性肿瘤。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To comprehensively summarize the characteristics of magnetic resonance imaging (MRI) findings of uterine adenosarcoma through a systematic review and case series analysis.
METHODS: A literature search was conducted in MEDLINE, Scopus, and Embase databases on June 3, 2024. In total, 25 cases from 23 articles were selected, and five cases from the authors' institution were included. Two board-certified radiologists evaluated the demographic, clinical, and radiological data.
RESULTS: The median age at diagnosis was 48.5 years (range: 9-79 years). The most frequent chief complaint was abnormal bleeding (96.7%), pathological T1 stage was predominant (85.2%), and 55.2% of the patients had sarcomatous overgrowth. Locoregional/distant recurrence occurred in 36.4% of the patients. MRI findings revealed that the mean longest lesion size was 9.3 cm. However, most lesions were located in the uterine body (93.1%) and primarily involved the endometrium (96.6%). Most cases (90.0%) were polypoid lesions with 80.8% protruding into the cervical canal. Cystic changes were prevalent (96.5%) and hemorrhage was observed in 84.6% of the evaluated cases. Lesions showed high (51.7%) or intermediate (48.3%) signal intensity compared with the uterine myometrium on T2-weighted imaging. Furthermore, all lesions showed heterogeneous enhancement on contrast-enhanced MRI, and the mean apparent diffusion coefficient value was 1.05 × 10-3 mm2/s.
CONCLUSION: Our findings provide a comprehensive analysis of MRI features in uterine adenosarcoma cases, highlighting key characteristics that may aid in preoperative diagnosis and differentiation from other uterine malignancies.
引用
- Morikawa K, Baba A, Matsushima S, et al. Magnetic resonance imaging features of uterine adenosarcoma: case series and systematic review. Abdom Radiol (NY). 2024. PMID: 39729099. doi:10.1007/s00261-024-04704-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。