文献速递技术与安全CT

对放疗科引入商用人工智能自动勾画工具影响的审计

An audit of the impact of the introduction of a commercial artificial intelligence-driven auto-contouring tool into a radiotherapy department.
PubMed 文献 · Br J Radiol · 2025-01-01

本前瞻性审计纳入248例患者和32名工作人员,评估商用人工智能自动勾画工具(AIAC)的准确性、省时性和实用性。结果显示,对AIAC的感知有用性随使用经验增加而提高(P < .05);80%的部位应用AIAC可省时,轻微编辑后轮廓临床可接受;乳腺和前列腺路径从CT到计划完成的中位时间分别减少5.5和9个工作日(P < .01);肿瘤科医生工作与生活平衡改善,每周最多增加2小时用于职业发展和研究。

要点

  • 对80%的部位,AIAC可省时且轻微编辑后轮廓临床可接受。
  • 乳腺和前列腺路径从CT到计划完成的中位时间分别减少5.5和9个工作日(P < .01)。
  • 多数病例中编辑对剂量影响很小。

核心结论

  • AIAC的所有使用者均认为其是有用工具并提高了工作效率。
  • 轮廓质量高且需要很少编辑;减少了勾画时间,并在部分病例中将从CT到计划完成的时间缩短了数天。
  • 释放的时间因工作人员组别而异。

研究设计与样本

  • 前瞻性审计,纳入248例患者和32名工作人员,评估商用人工智能自动勾画工具(AIAC)的感知有用性、临床可接受性和时间再分配。
  • 审计了若干路径下从CT到计划完成的时间(患者计划流转时间,PPTT)。

诊断标准与关键数值

  • 对80%的部位,AIAC可省时且AI轮廓在轻微编辑后临床可接受。
  • 感知有用性随接触AIAC而增加(P < .05)。
  • 从CT到计划完成的中位时间在乳腺路径减少5.5个工作日、前列腺路径减少9个工作日(P < .01)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To audit prospectively the accuracy, time saving, and utility of a commercial artificial intelligence auto-contouring tool (AIAC). To assess the reallocation of time released by AIAC.

METHODS: We audited the perceived usefulness (PU), clinical acceptability, and reallocation of time during the introduction of a commercial AIAC. The time from CT to plan completion [patient planning transit time (PPTT)] was audited for several pathways.

RESULTS: In this audit, 248 patients and 32 staff were included. PU increased with exposure to AIAC (P < .05). For 80% of sites, AIAC was timesaving and AI contours were clinically acceptable after minor edits. Edits had little impact on doses for the majority of cases. Median PPTT reduced by 5.5 (breast) and 9 (prostate) working days (P < .01). Radiographers spent more time on other tasks within planning. Oncologists improved their work-life balance and increased time spent on professional development and research by up to 2 h per week.

CONCLUSIONS: All users of AIAC found it a useful tool and it improved their productivity. The contours were high quality and needed little editing. It reduced contouring time and reduced PPTT by several days in some cases. The reallocated time was staff group dependent.

ADVANCES IN KNOWLEDGE: The time released by the use of AIAC can lead to a reduction in the PPTT by up to 9 days. It also improves the work-life balance of oncologists by reducing the time spent out of hours contouring.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Langmack KA, Alexander GG, Gardiner J, et al. An audit of the impact of the introduction of a commercial artificial intelligence-driven auto-contouring tool into a radiotherapy department. Br J Radiol. 2025. PMID: 39705202. doi:10.1093/bjr/tqae255

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。