前列腺液对表观扩散系数的影响:一项反转恢复扩散加权成像研究
该单中心前瞻性研究于2023至2024年纳入12名健康男性志愿者(45±17岁)和1例前列腺腺癌患者(66岁),采用16个反转时间(TI,60-4000毫秒)的反转恢复准备扩散加权成像(b值50和800 s/mm²),用双室模型(组织与液体)解读ADC。结果显示健康志愿者移行区ADC在TI=60毫秒至约1100毫秒间升高、随后骤降再升高并在很长TI时稳定,该效应在患者前列腺癌病灶中大幅减弱;前列腺液似乎对前列腺ADC有显著贡献,其贡献可通过选择适当反转恢复准备来调整,可能增强前列腺癌病灶的对比。
要点
- 前列腺ADC对比受前列腺液贡献影响,可用反转恢复准备调节液体抑制程度。
- 健康志愿者移行区ADC在TI=60毫秒至约1100毫秒间升高,随后骤降再升高并在很长TI时稳定。
- 该ADC随TI变化的特征在患者前列腺癌病灶中大幅减弱。
核心结论
- 前列腺液似乎对前列腺ADC有显著贡献,其贡献可通过选择适当的反转恢复准备来调整,可能增强前列腺癌病灶的对比。
研究设计与样本
- 该研究为机构审查委员会批准的单中心前瞻性研究,于2023至2024年开展。
- 共纳入12名健康男性志愿者(45±17岁)和1例前列腺腺癌患者(66岁)。
- 所有参与者接受磁共振成像,包括b值为50和800 s/mm²、16个反转时间(TI,60-4000毫秒)的扩散加权成像。
- 测得的ADC采用双室模型(室:组织与液体)解读,并对所有分析参数计算描述性统计。
关键影像表现/征象
- ADC图表现高度依赖TI,观察到特征丰富的ADC(TI)曲线。
- 健康志愿者移行区ADC在TI=60毫秒至约1100毫秒间升高,随后骤降,再升高并在很长TI时稳定。
- 该效应在患者前列腺癌病灶中大幅减弱。
- 反转后组织磁化恢复更快,其信号贡献绝对值下降,导致ADC升高。
- 在 tipping point 时,b=0处总磁化为零,正向组织磁化与仍反转的液体磁化相互抵消;小扩散编码产生正向信号,从而产生无限ADC;tipping point后液体磁化仍为负,从而降低ADC。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Diffusion-weighted imaging (DWI) is pivotal for prostate magnetic resonance imaging. This is rooted in the generally reduced apparent diffusion coefficient (ADC) observed in prostate cancer in comparison to healthy prostate tissue. This difference originates from microstructural tissue composition changes, including a potentially decreased fluid-containing lumen volume. This study explored the nature of the observed ADC contrast in prostate tissue through inversion recovery-prepared DWI examinations that generated varying levels of fluid suppression.
MATERIALS AND METHODS: This institutional review board-approved, single-center, prospective study was conducted from 2023 to 2024; all participants underwent magnetic resonance imaging including DWI with b-values of 50 and 800 s/mm 2 at 16 inversion times (TI; 60-4000 milliseconds). The measured ADC was interpreted with a 2-compartment model (compartments: tissue and fluid). Descriptive statistics were computed for all analyzed parameters.
RESULTS: Twelve healthy male volunteers (45 ± 17 years) and 1 patient with prostate adenocarcinoma (66 years) were evaluated. The ADC map appearance depended heavily on the TI, and we observed a feature-rich ADC(TI) curve. The ADC in the transition zone (TZ) of healthy volunteers increased between TI = 60 milliseconds and approximately 1100 milliseconds, then dropped drastically before increasing again, stabilizing at a very high TI. This effect was greatly reduced in the patient's prostate cancer lesion. The 2-compartment model described this behavior well. After the inversion, tissue magnetization recovers faster, decreasing its signal contribution in absolute terms and resulting in an increase in the ADC. At the tipping point, the total magnetization is zero at b = 0, when the positive tissue magnetization and still-inverted fluid magnetization cancel out. A small diffusion encoding leads to a positive signal, thus generating an infinite ADC. After the tipping point, the fluid magnetization remains negative and thereby reduces the ADC.
CONCLUSIONS: Prostate fluid appears to contribute significantly to prostate ADCs. Its contribution could be adjusted by choosing an appropriate inversion recovery preparation, potentially enhancing contrast for prostate cancer lesions.
引用
- Skwierawska D, Bickelhaupt S, Bachl M, et al. Relevance of Prostatic Fluid on the Apparent Diffusion Coefficient: An Inversion Recovery Diffusion-Weighted Imaging Investigation. Invest Radiol. 2024. PMID: 39621870. doi:10.1097/RLI.0000000000001139
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。