文献速递泌尿生殖MR

现代低场0.55 T扫描仪与3 T扫描仪在前列腺MR成像中基于AI评估的筛查队列比较

AI-Based Evaluation of Prostate MR Imaging at a Modern Low-field 0.55 T Scanner Compared to 3 T in a Screening Cohort.
PubMed 文献 · Acad Radiol · 2024-12-02

在25例筛查客户中比较3 T与0.55 T扫描仪的前列腺双参数MRI,AI分割显示两场强间体积测量无显著差异,0.55 T的ADC值较3 T偏低但置信区间均在±20%非劣效界值内,T2加权像中央腺体与外周带对比度比值无差异。

要点

  • 0.55 T前列腺双参数MRI可行,AI分割体积与3 T无显著差异(p=0.13/0.38)。
  • 0.55 T的ADC值较3 T偏低:外周带-10.14%、中央腺体-4.68%,均在±20%非劣效界值内。
  • T2加权像中央腺体与外周带对比度比值在两场强间无差异。

核心结论

  • 0.55 T前列腺双参数成像可行:ADC值变化在常见扫描仪间范围内,T2加权像外周带与中央腺体对比度比值、体积测量及AI分割与3 T相比均无差异。

研究设计与样本

  • 25例筛查客户(61.6±7.5岁)先于3 T扫描仪检查,随后于0.55 T扫描仪行第二次检查,采集轴位T2加权和扩散加权成像(DWI)序列并行AI分割;采用Pearson相关系数、Bland-Altman图及配对t检验非劣效检验(界值±20%)比较分割、体积测量、ADC值及T2加权像中央腺体与外周带比值。

关键影像表现/征象

  • T2加权像中央腺体与外周带对比度比值在3 T与0.55 T间无差异。
  • AI分割所得外周带与中央腺体体积在3 T与0.55 T间无显著差异。

诊断标准与关键数值

  • 外周带体积3 T均值14.81(12.53-17.09)mL vs 0.55 T均值14.29(12.03-16.54)mL,p=0.13。
  • 中央腺体体积3 T均值23.07(15.06-31.08)mL vs 0.55 T均值22.77(14.41-31.12)mL,p=0.38。

临床应用与阅片要点

  • 0.55 T可用于前列腺双参数MRI筛查,AI分割与体积测量结果与3 T无显著差异。
  • 解读0.55 T的ADC值时需注意其较3 T系统性偏低(外周带约-10.14%、中央腺体约-4.68%)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the effect of lower field strength on quantitative apparent-diffusion-coefficient (ADC) values, contrast of the T2-weighted MR images and the performance of an AI-based segmentation.

MATERIALS AND METHODS: 25 screening clients (61.6 ± 7.5 years) from a study on a 3 T scanner were included and underwent a second examination on a 0.55 T scanner. Axial T2 weighted and diffusion-weighted images (DWI) sequences were acquired. An AI-based segmentation was performed. Based on this, the segmentation, volumetry, ADC values and the ratio of central gland (CG) and peripheral zone (PZ) in T2 weighting were compared by using correlations coefficient (Pearson), Bland-Altman plots and a non-inferior test with a paired t-test and a margin of ± 20% (lower and upper boundary).

RESULTS: Volumetric assessment (peripheral zone//central gland) showed no significant (p = 0.13//0.38) difference between 3 T (mean volume: 14.81 (12.53-17.09)//23.07 (15.06-31.08)mL) and 0.55 T (mean volume of 14.29 (12.03-16.54; p = 0.13)//22.77 (14.41-31.12)mL). The deviation of the 0.55 T ADC values from the 3 T values was -10.14% (-16.09% to -4.18%) for the PZ and -4.68% (-10.12-0.76%) for the CG. Therefore, all confidence intervals remained within a margin of + /- 20% and thus demonstrated significant non-inferiority.

CONCLUSION: Biparametric prostate imaging is feasible at 0.55 T: ADC values vary within a common inter-scanner range compared to a 3 T and no difference can be observed regarding contrast ratio between peripheral zone and central gland in T2 weighted images, volumetry and AI-based segmentation compared to 3 T.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Segeroth M, Breit HC, Wasserthal J, et al. AI-Based Evaluation of Prostate MR Imaging at a Modern Low-field 0.55 T Scanner Compared to 3 T in a Screening Cohort. Acad Radiol. 2024. PMID: 39627058. doi:10.1016/j.acra.2024.11.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。