文献速递泌尿生殖MR

自动化24分区网格图算法用于前列腺多参数MRI可提高前列腺病灶位置报告的精确性和效率

Automated 24-sector grid-map algorithm for prostate mpMRI improves precision and efficacy of prostate lesion location reporting.
PubMed 文献 · Eur J Radiol · 2024-12-20

本研究开发了基于深度学习自动分区的前列腺24分区自动网格图(ASG)算法,并在50例多参数MRI数据集上以两位专家共识阅片为参考标准验证其定位准确性。ASG算法正确识别标注病灶所在前列腺分区的比例为80%(40/50次判读),高于四位放射科医师的55%(109/200),P<0.0001;叠加24分区ASG图后四位医师正确分区标注率提高至71%(141/200),P<0.004。

要点

  • ASG算法正确识别前列腺分区比例为80%(40/50次判读),优于四位放射科医师的55%(109/200)。
  • 叠加24分区ASG图后四位医师正确分区标注率由55%(109/200)提高至71%(141/200)。
  • PI-RADS要求报告前列腺索引病灶及移行区或外周带位置并标注于对应分区图。

核心结论

  • 24分区ASG图可有效用于前列腺分区分割,并显著改善前列腺病灶位置报告。

研究设计与样本

  • 基于自动分区特异性深度学习前列腺分割开发前列腺24分区自动网格图(ASG),在50例多参数MRI数据集上放置随机位置基准点并由两位专家泌尿放射科医师共识阅片确定参考分区,ASG自动评估与四位放射科医师两次判读(有无叠加分区网格图辅助)的成功率进行比较。

诊断标准与关键数值

  • ASG算法识别标注病灶正确前列腺分区的比例为80%(40/50次判读),四位放射科医师为55%(109/200),P<0.0001。
  • 四位放射科医师叠加24分区ASG图后正确分区标注率为71%(141/200),P<0.004。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: The Prostate Imaging-Reporting and Data System (PI-RADS) calls for reporting the prostate index lesion and the location within the transition (TZ) or peripheral zone (PZ) and location on a corresponding sector map. The aim of this study was to train a deep learning DL-based algorithm for automatic prostate sector mapping and to validate its' performance.

METHODS: An automatic 24-sector grid-map (ASG) of the prostate was developed, based on an automatic zone-specific deep learning segmentation of the prostate. To evaluate the efficacy of the method, fiducials for random locations within the prostate were placed, and the corresponding sectors were determined for 50 mpMRI datasets. The reference standard was defined in a consensus read by two expert uroradiologists. Annotated fiducial locations were evaluated automatically by the ASG and by four radiologists in two reads with and without the help of a superimposed sector grid-map and the success rate was compared.

RESULTS: The ASG algorithm identified the correct prostate sector of the annotated lesions in 80 % (40/50 reads) of the cases and outperformed readings of the four radiologists with 55 % (109/200), p < 0.0001. The added use of the 24 ASG map significantly improved the rate of correct sector annotation for the four radiologists to 71 % (141/200), p < 0.004.

CONCLUSION: The 24 ASG map was effective for prostate sector segmentation and significantly improved location reporting of prostate lesions.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Walter-Rittel TC, Frisch A, Hamm CA, et al. Automated 24-sector grid-map algorithm for prostate mpMRI improves precision and efficacy of prostate lesion location reporting. Eur J Radiol. 2024. PMID: 39729944. doi:10.1016/j.ejrad.2024.111897

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。