合成扩散加权成像在前列腺癌诊断中的应用:不同b值组合的比较研究
回顾性分析68例PSA异常患者,用五种b值组合重建b=1500 s/mm²的合成DWI并比较图像质量与前列腺癌诊断效能。所有合成DWI对比度均高于实际DWI,b≤200 s/mm²与b≥600 s/mm²组合的图像质量主观评分及AUC较优,作者认为该组合为最佳b值组合。
要点
- 合成DWI(b=1500 s/mm²)对比度均高于实际DWI(b=1500 s/mm²)。
- sDWI0-600、sDWI200-800、sDWI0-800主观评分显著高于其他组(背景信号抑制除外)。
- 方案Ⅲ、Ⅳ、Ⅴ、Ⅵ的AUC显著大于其他方案。
核心结论
- 不同b值组合影响合成DWI的图像质量和前列腺癌诊断准确率,b≤200 s/mm²与b≥600 s/mm²的组合为最佳。
研究设计与样本
- 回顾性分析68例前列腺特异性抗原异常患者,比较五种b值组合重建的合成DWI与实际DWI(b=1500 s/mm²)的图像质量和诊断效能。
关键影像表现/征象
- 所有合成DWI图像的对比度值均高于实际DWI(b=1500 s/mm²)图像。
- sDWI0-200与sDWI600-800的对比噪声比低于其余合成DWI图像。
- sDWI0-600、sDWI200-800、sDWI0-800的主观质量评分除背景信号抑制外均显著高于其他组。
诊断标准与关键数值
- 方案Ⅲ(T2WI+sDWI0-600)、方案Ⅳ(T2WI+sDWI200-800)、方案Ⅴ(T2WI+sDWI0-800)、方案Ⅵ(T2WI+aDWI1500)的AUC显著大于其他方案。
- 合成DWI均以b=1500 s/mm²重建,b值组合分别为0、200 s/mm²;600、800 s/mm²;0、600 s/mm²;200、800 s/mm²;0、800 s/mm²。
- 由两名放射科医师对六组图像从五个方面进行主观质量评分,并通过ROC曲线评估前列腺癌诊断效能。
临床应用与阅片要点
- 合成DWI(b=1500 s/mm²)较实际DWI(b=1500 s/mm²)具有更高对比度,其中b≤200 s/mm²与b≥600 s/mm²组合在主观质量和诊断效能上表现较优。
- b=0、200 s/mm²或b=600、800 s/mm²组合的对比噪声比相对较低,阅片时需注意图像质量差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate the impact of different b-value combinations on synthetic diffusion-weighted imaging (sDWI) and determine the sDWI with an optimal b-value combination for prostatic cancer (PCa) diagnosis.
MATERIAL AND METHODS: A retrospective analysis of 68 patients with abnormal prostate-specific antigen (PSA) was conducted. The sDWI images with b value of 1500 s/mm2 were separately reconstructed by the following five b-value combinations: b=0, 200s/mm2 (sDWI0-200); b=600, 800s/mm2 (sDWI600-800); b=0, 600s/mm2 (sDWI0-600); b=200, 800s/mm2 sDWI200-800); b=0, 800s/mm2 (sDWI0-800). Quantitative analysis was performed on the acquired DWI (aDWI) images with b=1500s/mm2 (aDWI1500) and all sDWI images. These six image groups were scored in five aspects for image quality and further reviewed by two radiologists via six protocols: Protocol Ⅰ, T2WI+sDWI0-200; Protocol Ⅱ, T2WI+sDWI600-800; Protocol Ⅲ, T2WI+sDWI0-600; Protocol Ⅳ, T2WI+sDWI200-800; Protocol Ⅴ, T2WI+sDWI0-800; Protocol Ⅵ, T2WI+aDWI1500. The corresponding diagnostic efficacies for PCa were evaluated using receiver operating characteristic (ROC) curves.
RESULTS: Contrast ratio values of all sDWI images were higher than those of aDWI1500 images. Contrast-to-noise ratio values of sDWI0-200 and sDWI600-800 images were lower than those of the rest sDWI images. All subjective quality scores of sDWI0-600, sDWI200-800, and sDWI0-800 were significantly higher than other groups except for background signal suppression. The area under the curve (AUC) of Protocol Ⅲ, Ⅳ, Ⅴ, and Ⅵ was significantly larger than those of other protocols.
CONCLUSION: Different b-value combinations impact the image quality and diagnostic accuracy of sDWI for PCa detection. The combination of b≤200s/mm2 and b≥600s/mm2 revealed to be optimal.
引用
- He L, Zhang Z, Zhang J, et al. Synthetic diffusion-weighted imaging in prostate cancer diagnosis: a comparison study with different B-value combinations. Clin Radiol. 2024. PMID: 39736221. doi:10.1016/j.crad.2024.106770
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。