影像组学鉴别胰腺黏液性囊性肿瘤与浆液性囊性肿瘤:系统综述与Meta分析
该系统综述与Meta分析纳入8项研究共884例患者(365例黏液性囊性肿瘤、519例浆液性囊性肿瘤),评估影像组学鉴别两者的诊断准确性,合并敏感度0.84、特异度0.82、SROC曲线下面积0.93,未检出显著发表偏倚;基于感兴趣体积提取特征或使用人工智能分类器的模型表现优于基于感兴趣区或无人工智能分类器的方案。
要点
- 影像组学鉴别黏液性与浆液性囊性肿瘤的合并敏感度0.84、特异度0.82、SROC曲线下面积0.93。
- 基于感兴趣体积提取特征或使用人工智能分类器的影像组学模型表现更优。
- 该系统综述与Meta分析未检出显著发表偏倚。
核心结论
- 影像组学在鉴别黏液性囊性肿瘤与浆液性囊性肿瘤方面表现出高敏感度和特异度,有潜力成为可靠的诊断工具。
研究设计与样本
- 系统综述与Meta分析,检索Pubmed、Scopus和Web of Science数据库,纳入8项研究共884例患者(365例黏液性囊性肿瘤、519例浆液性囊性肿瘤),采用诊断准确性研究质量评价方法评估偏倚风险。
临床应用与阅片要点
- 该系统综述与Meta分析显示影像组学有潜力成为鉴别黏液性囊性肿瘤与浆液性囊性肿瘤的可靠诊断工具。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: As pancreatic cystic neoplasms (PCN) differ in current standard of care, and these treatments can affect quality of life to varying degrees, a definitive preoperative diagnosis must be reliable. Current diagnostic approaches, specifically traditional cross-sectional imaging techniques, face certain limitations. But radiomics has been shown to have high diagnostic accuracy across a range of diseases. Objective to conduct a comprehensive review of the literature on the use of radiomics to differentiate Mucinous Cystic Neoplasm (MCN) from Serous Cystic Neoplasm (SCN).
METHODS: This study was comprehensively searched in Pubmed, Scopus and Web of Science databases for meta-analysis of studies that used radiomics to distinguish MCN from SCN. Risk of bias was assessed using the diagnostic accuracy study quality assessment method and combined with sensitivity, specificity, diagnostic odds ratio, and summary receiver operating characteristic (SROC)curve analysis.
RESULTS: A total of 884 patients from 8 studies were included in this analysis, including 365 MCN and 519 SCN. The Meta-analysis found that radiomics identified MCN and SCN with high sensitivity and specificity, with combined sensitivity and specificity of 0.84(0.82-0.87) and 0.82(0.79-0.84). The positive likelihood ratio (PLR) and the negative likelihood ratio (NLR) are 5.61(3.72, 8.47) and 0.14(0.09-0.26). In addition, the area under the SROC curve (AUC) was drawn at 0.93. No significant risk of publication bias was detected through the funnel plot analysis. The performances of feature extraction from the volume of interest (VOI) or Using AI classifier in the radiomics models were superior to those of protocols employing region of interest (ROI) or absence of AI classifier.
CONCLUSION: This meta-analysis demonstrates that radiomics exhibits high sensitivity and specificity in distinguishing between MCN and SCN, and has the potential to become a reliable diagnostic tool for their identification.
引用
- Zhang L, Diao B, Fan Z, et al. Radiomics for Differentiating Pancreatic Mucinous Cystic Neoplasm from Serous Cystic Neoplasm: Systematic Review and Meta-Analysis. Acad Radiol. 2024. PMID: 39648097. doi:10.1016/j.acra.2024.11.047
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。