SMART:用于急诊环境下腹部创伤的多模态多器官创伤筛查模型的开发与应用
本研究基于非增强CT与无结构文本数据构建腹部创伤多模态诊断模型SMART,纳入2638例患者(阳性459例、阴性2179例)。SMART_GPT敏感度81.3%、AUC 0.88,SMART_Image敏感度87.5%、AUC 0.81,整合模型敏感度93.8%、AUC 0.88;急诊模拟中等待时间缩短超过64.24%。
要点
- 整合文本与平扫CT的多模态模型敏感度93.8%,高于单模态。
- 器官层面SMART_Image平均敏感度超过90%。
- 急诊模拟中该模型使等待时间缩短超过64.24%。
核心结论
- SMART模型可提供快速、客观的创伤诊断,提高急诊诊疗效率、缩短患者等待时间,并支持多种急诊场景下的多模态筛查。
研究设计与样本
- 研究纳入接受腹部CT扫描的患者2638例(腹部创伤阳性459例、阴性2179例),构建并验证SMART模型(含SMART_GPT、SMART_Image及两者联合的整合模型)。
诊断标准与关键数值
- SMART_GPT基于无结构文本数据,敏感度81.3%,AUC 0.88。
- SMART_Image基于非增强CT数据,敏感度87.5%,AUC 0.81。
- SMART_Image在器官层面平均敏感度超过90%。
- 整合SMART模型敏感度93.8%,AUC 0.88。
临床应用与阅片要点
- SMART_GPT采用GPT-4嵌入API提取文本特征,SMART_Image采用nnU-Net与DenseNet121完成分割与分类。
- 整合模型通过逻辑回归融合SMART_GPT、SMART_Image及患者人口学信息(年龄与性别)。
- 研究使用含1006例患者、1632个真实连续数据点的创伤数据集进行测试。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Effective trauma care in emergency departments necessitates rapid diagnosis by interdisciplinary teams using various medical data. This study constructed a multimodal diagnostic model for abdominal trauma using deep learning on non-contrast computed tomography (CT) and unstructured text data, enhancing the speed and accuracy of solid organ assessments.
MATERIALS AND METHODS: Data were collected from patients undergoing abdominal CT scans. The SMART model (Screening for Multi-organ Assessment in Rapid Trauma) classifies trauma using text data (SMART_GPT), non-contrast CT scans (SMART_Image), or both. SMART_GPT uses the GPT-4 embedding API for text feature extraction, whereas SMART_Image incorporates nnU-Net and DenseNet121 for segmentation and classification. A composite model was developed by integrating multimodal data via logistic regression of SMART_GPT, SMART_Image, and patient demographics (age and gender).
RESULTS: This study included 2638 patients (459 positive, 2179 negative abdominal trauma cases). A trauma-based dataset included 1006 patients with 1632 real continuous data points for testing. SMART_GPT achieved a sensitivity of 81.3% and an area under the receiver operating characteristic curve (AUC) of 0.88 based on unstructured text data. SMART_Image exhibited a sensitivity of 87.5% and an AUC of 0.81 on non-contrast CT data, with the average sensitivity exceeding 90% at the organ level. The integrated SMART model achieved a sensitivity of 93.8% and an AUC of 0.88. In emergency department simulations, SMART reduced waiting times by over 64.24%.
CONCLUSION: SMART provides rapid, objective trauma diagnostics, improving emergency care efficiency, reducing patient wait times, and enabling multimodal screening in diverse emergency contexts.
引用
- Wang Y, Zhang J, Li M, et al. SMART: Development and Application of a Multimodal Multi-organ Trauma Screening Model for Abdominal Injuries in Emergency Settings. Acad Radiol. 2024. PMID: 39690074. doi:10.1016/j.acra.2024.11.056
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。