文献速递腹部泌尿生殖MRCT

模拟简化肝脏磁共振成像联合增强CT在结直肠癌患者肝脏基线评估中的临床表现

Clinical performance of a simulated abbreviated liver magnetic resonance imaging in combination with contrast-enhanced computed tomography for the baseline evaluation of the liver in patients with colorectal cancer.
PubMed 文献 · Clin Radiol · 2024-11-05

本研究纳入75例结直肠癌患者(245个转移灶、122个良性病灶),由3名阅片者独立评估标准钆塞酸肝脏MRI方案与模拟简化方案(T2w、HBP、DWI联合CE-CT)的诊断准确性和一致性。两种方案各阅片者诊断准确性无显著差异(平均P=0.74),转移灶和良性病灶总数高度一致(κ=0.81、0.78),转移灶总数阅片者间一致性极好(ICC=0.99、0.99),结论为基线时模拟简化肝脏MRI联合CE-CT与标准MRI方案在肝转移灶检测上具有极好的一致性。

要点

  • 模拟简化方案(T2w、HBP、DWI联合CE-CT)与标准钆塞酸MRI方案诊断准确性无显著差异(平均P=0.74)。
  • 两方案转移灶和良性病灶总数高度一致(κ=0.81、0.78),转移灶总数阅片者间ICC均为0.99。
  • 转移灶肝段受累的一致性良好(κ=0.84-0.99)。

核心结论

  • 基线时使用模拟简化肝脏MRI联合CE-CT与标准MRI方案在肝转移灶检测上具有极好的一致性。

研究设计与样本

  • 诊断准确性研究,纳入75例结直肠癌患者(245个转移灶、122个良性病灶),3名阅片者独立评估两套图像,以标准钆塞酸MRI方案(T1w、T2w、DWI、多期CE-T1w及HBP)为参照,比较模拟简化方案(T2w、HBP、DWI联合CE-CT)的诊断表现。

诊断标准与关键数值

  • 各阅片者两种方案诊断准确性无显著差异(McNemar检验,平均P=0.74)。
  • 转移灶和良性病灶总数两方案间高度一致(κ=0.81、0.78)。
  • 转移灶总数阅片者间一致性极好(ICC=0.99、0.99)。
  • 转移灶肝段受累一致性良好(κ=0.84-0.99)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To assess the diagnostic accuracy and inter-reader agreement of a simulated abbreviated gadoxetate liver magnetic resonance imaging (MRI) protocol together with contrast-enhanced computed tomography (CE-CT) against a standard gadoxetate MRI for the detection of colorectal liver metastases at baseline.

MATERIALS AND METHODS: Three readers independently evaluated two sets of images per patient, recording number and location of metastases and benign lesions. Set 1 comprised T1w, T2w, DWI, multiphase CE-T1w, and hepatobiliary phase (HBP) images (standard). Set 2 included T2w, HBP, DWI (from Set 1) and CE-CT (simulated abbreviated). Diagnostic performance was compared using McNemar's test. The level of agreement between sets 1 and 2 was determined with Cohen kappa. For agreement in the number of benign lesions and metastases, we applied intraclass correlation coefficient (ICC).

RESULTS: Seventy-five patients (245 metastases, 122 benign lesions) were evaluated. There was no significant difference in diagnostic accuracy between set 1 and 2 for each reader (mean P = 0.74). The total number of metastases and benign lesions showed high agreement between reading set 1 and 2 (κ = 0.81, 0.78). The total number of metastases showed substantial agreement between readers for set 1 and 2 (ICC = 0.99, 0.99). Good agreement was seen for metastatic segmental involvement (κ = 0.84-0.99).

CONCLUSION: At baseline, using a simulated abbreviated liver MRI together with CE-CT showed excellent agreement with standard MRI protocol for liver metastasis detection.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Castagnoli F, Withey SJ, Konidari M, et al. Clinical performance of a simulated abbreviated liver magnetic resonance imaging in combination with contrast-enhanced computed tomography for the baseline evaluation of the liver in patients with colorectal cancer. Clin Radiol. 2024. PMID: 39631364. doi:10.1016/j.crad.2024.106743

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。