肝脏炎性假瘤的临床与多模态影像特征:一项双中心回顾性研究
本研究纳入两家医疗机构经组织学证实的83例肝脏炎性假瘤患者,分析其常规超声、超声造影及增强CT/增强MRI特征。超声造影典型表现为动脉期轻度高增强或等增强、静脉期快速廓清及内部小片无增强区,其廓清模式与增强CT/增强MRI不一致,更类似胆管癌,但三种方法诊断敏感度无统计学差异。
要点
- 肝脏炎性假瘤超声造影典型表现为动脉期轻度高增强或等增强、静脉期快速廓清(<60秒)及内部小无增强区。
- 超声造影的廓清模式与增强CT/增强MRI不一致,更类似胆管癌,阅片时需注意鉴别。
- 超声造影、增强CT与增强MRI诊断肝脏炎性假瘤的敏感度无统计学差异(P>.05)。
核心结论
- 肝脏炎性假瘤的超声造影特征通常为动脉期轻度高增强或等增强、静脉期快速廓清、肿块内常伴小片无增强区;超声造影与增强CT/增强MRI的廓清模式不一致,更类似胆管癌;三种方法诊断效能相似。
研究设计与样本
- 双中心回顾性研究,纳入83例经组织学证实的肝脏炎性假瘤患者,所有患者术前或活检前1周内接受超声造影,部分患者 additional 接受增强CT或增强MRI。
关键影像表现/征象
- 常规超声上,肝脏炎性假瘤主要表现为低回声(83.5%,66/79)、形态不规则(62.0%,49/79)、回声不均匀(72.2%,57/79)及边界不清(65.8%,52/79)。
- 超声造影上,61.5%(51/83)病灶动脉期呈轻度高增强或等增强,59.0%(49/83)病灶内部有无增强区。
- 超声造影上,多数病灶(71.1%,59/83)表现为早期廓清(<60秒)。
诊断标准与关键数值
- 超声造影与增强CT/增强MRI在动脉期增强强度和廓清模式上差异有统计学意义(P < .05)。
- 超声造影、增强CT与增强MRI诊断肝脏炎性假瘤的敏感度无统计学差异(P>.05)。
临床应用与阅片要点
- 超声造影出现动脉期轻度高增强或等增强、静脉期快速廓清(<60秒)及内部小无增强区时,需将肝脏炎性假瘤纳入鉴别诊断。
- 超声造影的廓清模式与增强CT/增强MRI不一致,更类似胆管癌,阅片和报告时应结合多模态影像综合判断。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Current literature on imaging characteristics of hepatic inflammatory pseudotumor (HIPT) is limited. This study aimed to analyze the contrast-enhanced ultrasound (CEUS) features in HIPT and compare them with contrast-enhanced computed tomography (CECT) and contrast-enhanced magnetic resonance imaging (CEMRI).
METHODS: A total of 83 patients with histologically proven HIPT from two medical institutions were included in this study. All patients underwent CEUS within 1 week before surgery or biopsy. Some patients received additional CECT or CEMRI. B-mode ultrasound (BMUS) features, enhancement parameters of CEUS, CECT and CEMRI were analyzed. Chi-square test was used to compare the enhancement patterns and diagnostic sensitivity between CEUS and CECT/CEMRI.
RESULTS: On the BMUS, HIPT mainly appeared hypoechoic (83.5%, 66/79), irregular shapes (62.0%, 49/79), heterogeneous echogenicity (72.2%, 57/79), and unclear boundary (65.8%, 52/79). A total of 61.5% (51/83) lesions exhibited mild hyper- or iso-enhancement in the arterial phase (AP), 59.0% (49/83) lesions had internal nonenhanced areas, and most lesions (71.1%, 59/83) showed early wash-out (<60 seconds) on the CEUS. There were significant differences between CEUS and CECT/CEMRI in enhancement intensity of AP and wash-out pattern (P < .05). The sensitivity in the diagnosis of HIPT among the three had no statistical difference (P>.05).
CONCLUSIONS: The CEUS features of HIPT lesions typically include mildly hyper-enhanced or iso-enhanced in AP, rapid wash-out in PVP, and often small nonenhanced areas within the mass. Furthermore, the wash-out pattern of CEUS and CECT/CEMRI are inconsistent, more akin to cholangiocarcinoma. The diagnostic efficacy of the three modalities is similar.
引用
- Chen K, Luo M, He Y, et al. Clinical and Multimodal Imaging Features of Hepatic Inflammatory Pseudotumors: A Two-Center Retrospective Study. J Ultrasound Med. 2024. PMID: 39665519. doi:10.1002/jum.16629
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。