低Agatston积分患者中非对比增强与对比增强CT影像组学预测冠状动脉斑块的效能比较
本研究回顾性分析459例疑似冠心病且冠状动脉钙化积分<100 Agatston单位的患者,比较低剂量非对比心脏CT与冠状动脉CT血管成像(CCTA)的冠周脂肪组织(PCAT)影像组学预测冠状动脉斑块的效能,以CCTA为参考标准。两种混合模型在训练集(r=0.890,P<0.001)和验证集(r=0.920,P<0.001)均显示显著相关。结论认为非对比CT PCAT影像组学在预测低Agatston积分患者冠状动脉斑块方面与CCTA PCAT影像组学效能相当。
要点
- 非对比CT PCAT影像组学预测斑块效能与CCTA PCAT影像组学相当。
- 混合模型在训练集r=0.890、验证集r=0.920,均P<0.001。
- 训练集平均一致性为0,3.42%(11/322)数据点超出95%CI(-0.18-0.18)。
核心结论
- 非对比CT PCAT影像组学在低Agatston积分患者中预测冠状动脉斑块的效能与CCTA PCAT影像组学相当。
研究设计与样本
- 回顾性研究,纳入2021年6月至2023年12月一家三级医院459例疑似冠心病且冠状动脉钙化积分<100 Agatston单位的患者,以CCTA为参考标准,构建临床因素模型、临床+CT PCAT影像组学混合模型、临床+CCTA PCAT影像组学混合模型,采用多变量逻辑回归和ROC曲线评估。
诊断标准与关键数值
- 两种混合模型在训练集相关系数r=0.890(P<0.001),验证集r=0.920(P<0.001);训练集平均一致性为0,3.42%(11/322)数据点超出95%CI(-0.18-0.18,P<0.001);验证集平均一致性为-0.244,6.57%(9/137)数据点超出95%CI(-0.443-0.045,P<0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Patients with a low Agatston score often present with clinical signs and symptoms suggestive of coronary artery disease, despite having minimal calcium deposits. This study aimed to compare the efficacy of low-dose non-contrast cardiac CT with coronary computed tomography angiography (CCTA) in pericoronary adipose tissue (PCAT) radiomics for predicting coronary artery plaques, using CCTA as the reference standard.
MATERIALS AND METHODS: This retrospective study analyzed 459 patients with suspected coronary artery disease and a coronary artery calcium score < 100 Agatston units, who were treated between June 2021 and December 2023 at a tertiary hospital. Three predictive models for coronary artery plaques were developed: (1) a clinical factor model, (2) a hybrid model integrating clinical factors and CT PCAT radiomics, and (3) a hybrid model integrating clinical factors and CCTA PCAT radiomics. Multivariable logistic regression and receiver operating characteristic curve evaluations were performed to develop and validate predictive models.
RESULTS: Both hybrid models showed significant correlations in the training set (r = 0.890, P < 0.001) and the validation set (r = 0.920, P < 0.001). The mean agreement in the training set is 0, with 3.42% (11/322) of the data points outside the 95% CI (-0.18-0.18, P < 0.001). The mean agreement in the validation set is -0.244, with 6.57% (9/137) of the data points outside the 95% CI (-0.443-0.045, P < 0.001).
CONCLUSIONS: Non-contract CT PCAT radiomics showed comparable efficacy to CCTA PCAT radiomics in predicting coronary artery plaques among patients with low Agatston scores.
引用
- Liang J, Lin C, Qi H, et al. Comparative Efficacy of Non-contrast vs. Contrast-enhanced CT Radiomics in Predicting Coronary Artery Plaques Among Patients with Low Agatston Scores. Acad Radiol. 2024. PMID: 39694786. doi:10.1016/j.acra.2024.11.063
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。