运动心电图联合碲化镉锌心脏专用单光子发射计算机断层成像预测冠状动脉疾病
研究纳入124例20-85岁患者,评估运动心电图试验(EET)联合碲化镉锌心脏专用SPECT(CZT-SPECT)诊断冠状动脉疾病(CAD)的效能,以冠状动脉造影>50%狭窄为参考标准。联合检查的敏感度60.00%、特异度90.57%、阳性预测值54.55%、阴性预测值92.31%,阳性似然比6.36。结论认为联合CZT-SPECT与EET较任一方法单独应用可显著提高CAD诊断准确性。
要点
- CZT-SPECT单独诊断CAD特异度92.06%、阳性似然比4.54,敏感度仅36.07%。
- EET单独诊断CAD敏感度31.58%、特异度80%、阳性似然比1.58。
- 联合检查阴性预测值92.31%、阳性似然比6.36,敏感度升至60.00%。
核心结论
- 联合CZT-SPECT与EET较任一方法单独应用可显著提高CAD诊断准确性。
研究设计与样本
- 研究对124例20-85岁患者行CZT-SPECT与EET检查,随后行冠状动脉造影,评估单独及联合检查的敏感度、特异度、阳性预测值和阴性预测值。
- CAD定义为冠状动脉造影时存在>50%狭窄。
诊断标准与关键数值
- EET单独诊断CAD:敏感度31.58%、特异度80%、阳性预测值22.22%、阴性预测值86.6%、阳性似然比1.58。
- CZT-SPECT单独诊断CAD:敏感度36.07%、特异度92.06%、阳性预测值81.48%、阴性预测值59.79%、阳性似然比4.54。
- EET联合CZT-SPECT诊断CAD:敏感度60.00%、特异度90.57%、阳性预测值54.55%、阴性预测值92.31%、阳性似然比6.36。
- CAD参考标准为冠状动脉造影显示>50%狭窄。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: Coronary artery disease (CAD) is a primary cause of mortality, prompting ongoing research into noninvasive diagnostic modalities. This study aimed to evaluate the diagnostic efficacy of exercise electrocardiography testing (EET) combined with cadmium zinc tellurium cardiac-dedicated single photon emission computed tomography (CZT-SPECT) imaging for CAD.
MATERIALS AND METHODS: CZT-SPECT and EET were examined in 124 patients aged 20-85 years, followed by coronary angiography to evaluate the sensitivity, specificity, positive predictive value, and negative predictive value of EET/CZT-SPECT alone and in combination. CAD was defined as the presence of > 50% stenosis at the time of coronary angiography.
RESULTS: The sensitivity of the EET test alone was 31.58%, the specificity was 80%, the positive predictive value (PPV) was 22.22%, and the negative predictive value (NPV) was 86.6%. The corresponding values of CZT-SPECT alone were 36.07%, 92.06%, 81.48% and 59.79%, respectively. The combined results showed that the sensitivity, specificity, PPV, and NPV were 60.00%, 90.57%, 54.55%, and 92.31%, respectively. In this study, the positive likelihood ratio (PLR) diagnosed with EET alone was 1.58, the PLR diagnosed with CZT-SPECT alone was 4.54, and the PLR diagnosed with combination was 6.36.
CONCLUSION: The combination of CZT-SPECT and EET showed significantly improved CAD diagnostic accuracy compared with either approach alone.
引用
- Wu M, Xu Z, Huang Q, et al. Exercise electrocardiogram combined with cadmium zinc tellurium (CZT) cardiac-dedicated single photon emission computed tomography (SPECT) predicts coronary artery disease. Clin Radiol. 2024. PMID: 39736220. doi:10.1016/j.crad.2024.106769
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。