光子计数与能量积分探测器CT测量冠状动脉周围脂肪衰减指数的个体内差异

Intra-individual Differences in Pericoronary Fat Attenuation Index Measurements Between Photon-counting and Energy-integrating Detector Computed Tomography.
PubMed 文献 · Acad Radiol · 2024-12-10

研究前瞻性纳入40例患者,在EID-CT后30天内行PCD-CT扫描,比较不同重建方式下冠状动脉周围脂肪衰减指数(FAI)的个体内差异。结果显示,在控制重建核和层厚时,EID-CT与PCD-CT的绝对FAI测量值差异显著,但使用迭代重建可最小化多数FAI差异,使不同扫描仪间具有可比性。

要点

  • 在控制重建核和层厚条件下,EID-CT与PCD-CT的绝对冠状动脉周围FAI测量值差异显著(所有血管p<.001)。
  • 使用迭代重建时,多数血管的FAI在EID-CT与PCD-CT间无显著差异(如回旋支p>0.06)。
  • PCD-CT采用0.2 mm超高分辨率重建且关闭迭代重建时,FAI值较EID-CT进一步降低。

核心结论

  • 在控制重建核和层厚时,EID-CT与PCD-CT的个体内绝对PCAT FAI测量值差异显著;但使用迭代重建可最小化多数FAI差异,使不同扫描仪间具有可比性。

研究设计与样本

  • 前瞻性研究,纳入40例患者(平均年龄68±8岁,男性32例[80%]),在EID-CT后30天内行PCD-CT研究扫描。EID和PCD降采样图像均采用Qr36核、0.6 mm层厚重重建,PCD-CT另采用0.2 mm超高分辨率重建;迭代重建分别设为关闭(使用滤波反投影作为替代重建方法)或当前文献推荐水平。冠状动脉PCAT FAI采用既定阈值-190至-30 HU在设定距离和半径下自动测量。统计采用重复测量方差分析和Bonferroni多重比较检验(显著性定为p<0.003)。

诊断标准与关键数值

  • PCAT FAI测量使用既定阈值-190至-30 HU,在设定距离和半径下自动测量。

临床应用与阅片要点

  • 在比较EID-CT与PCD-CT的PCAT FAI测量值时,需注意重建方法的影响;使用迭代重建可减少扫描仪间FAI差异,有助于实现扫描仪间可比性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: The purpose of this study was to explore intra-individual differences in pericoronary adipose tissue (PCAT) fat attenuation index (FAI) between photon-counting detector (PCD)- and energy-integrating detector (EID)-CT.

MATERIAL AND METHODS: Patients were prospectively enrolled for a PCD-CT research scan within 30 days of EID-CT. Both acquisitions were reconstructed using a Qr36 kernel at 0.6 mm slice thickness (EID and PCD-down-sampled [DS]) and at 0.2 mm ultra-high resolution (UHR) for the PCD-CT. Iterative reconstruction was turned "off" (filter back projection used as alternative reconstruction method) or set to a recommended level in current literature. Coronary PCAT FAI was measured automatically using established thresholds of -190 to -30 HU at a set distance and radius. Statistical testing was performed using repeated-measures ANOVA and Bonferroni's multiple comparison tests (p significance was determined to be <0.003).

RESULTS: In total, 40 patients (mean age 68±8 years, 32 males [80%]) were included for analysis. Absolute FAI measurements differed significantly for all vessels between all reconstructions in the ANOVA comparison (all p<.001). The FAI decreased going from EID-CT to PCD-DS, to PCD-UHR with iterative reconstruction turned off (e.g. right coronary artery: EID-CT: -76.5±8.9 vs -80.9±7.0 vs -88.3±6.7 HU, respectively; p < 0.001). The mean FAI of datasets using iterative reconstruction did not demonstrate significant differences on multiple comparisons (e.g. left circumflex artery: EID: -65.7±8.5; PCD-DS: -66.0±7.4; PCD-UHR: -67.8±7.0 HU, respectively; p>0.06).

CONCLUSION: Intra-individual absolute PCAT FAI measurements differ significantly between EID- and PCD-CT when controlling for reconstruction kernel and slice thickness. However, the use of iterative reconstruction minimizes most differences in FAI, enabling inter-scanner comparability.

来源:Acad Radiol,查看原文。版权归原作者所有。